^^rGERAGHTY '& MILLER, INC. nvironmental Services Ground Water Engineering Hydrocarbon Remediation Education January 24, 1994 Caroline Kwan U.S. Environmental Protection Agency Region n 26 Federal Plaza, Room 737 New York, New York 10278 Re: Addendum to Appendix A - Soil Gas Survey Procedures, Phase II Remedial Investigation (RI) Work Plan, Tutu Wells Site, St. Thomas, U.S. Virgin Islands. Dear Ms. Kwan: As discussed in our January 21, 1993 meeting, Geraghty & Miller, Inc. has prepared this letter addendum to clarify the soil gas procedures presented in Appendix A of the Phase II Remedial Investigation (RI) Work Plan, Tutu Wells Site, St. Thomas, U.S. Virgin Islands (Geraghty & Miller, Inc. 1993). The U.S. Environmental Protection Agency's (USEPA) comments on Appendix A were presented in a draft letter to Ms. Ana Gloria Ramos, Tutu Environmental Investigation Committee (TEIC) Designated Coordinator, received on January 12, 1994. The specific responses or revisions to USEPA's concerns are presented below. A revised Appendix A (Revision 1.0) has been prepared based on your comments. Revision 1.0 of Appendix A (enclosed) supersedes and replaces the original version. Please include Revision 1.0 in Appendix A of Volume 2 of the Phase II RI Work Plan (Geraghty & Miller, Inc. 1993). • Page 3 - Geraghty & Miller defines a soil-gas "hot spot" as a location that has a soil-gas concentration that is an order of magnitude (10 times) greater than surrounding soil-gas values for other locations within the immediate area. These hot-spot areas may warrant further investigation. TUT 006 1290 201 West Passaic Street, 3rd Floor • Rochelle Park, New Jersey 07662* (201) 909-0700 • FAX (201) 909-0567/0568 *64749* 64749 OERAGHTY & MILLER, INC. • Page 4 - If a location contains concrete that is greater than 1 foot, the sample location will be relocated or abandoned. The drill cannot penetrate concrete or asphalt greater than 1 foot in thickness. • Pages 4 and 5 - The volume of the sample syringe is 500 ul. • Page" 5 - The sample syringe, teflon tubing and hosing apparatus will be purged with air between each sampling location. An air blank sample will be collected from this apparatus to determine that no cross-contamination is occurring. • Page 5 - Yes. Sample probes will be purged with air before each new sampling location. We hope this clarifies the soil gas procedures to your satisfaction. If you have any questions, please call. Sincerely, GERAGHTY & MILLER, INC. c: Ana Gloria Ramos, TEIC Paul Ryan, Texaco Sally Odlund, CDM JJ:nr PR0013.»«-WP2/012494.1tr Thomas V. Danahy // Senior Scientist/Project Manager Daniel A. Nachman Vice President/Project Officer TUT OO6 1291 APPENDIX A SOIL GAS SURVEY PROCEDURES TUTU WELLS SITE ST. THOMAS, U.S. VIRGIN THOMAS Revision 1.0, January 1994 GERAGHTY 6? MILLER, INC TUT °06 1292 G APPENDIX A SOIL GAS SURVEY TUTU WTCI^LS srns ST. THOMAS. U.S. VIRGIN THOMAS INTRODUCTION A soil-gas survey will be conducted at the Curriculum Center (former LAGA building) and the Virgin Islands Housing Authority (VIHA) maintenance area to identify potential sources of volatile organic compounds (VOCs) in soil. The study will be conducted in accordance with details outlined in Section 7.1.3 (Soil-Gas Surveys) of the Phase n Remedial Investigation (RI) Work Plan. VOCs detected by a soil-gas survey can originate directly from VOCs in the soil or from VOCs diffused upward into the soil atmosphere from ground water. Soil-gas surveys provide a qualitative indication of VOCs in the unsaturated zone, rather than a quantitative '"""^ indication of VOCs in the soil or the ground water, because site-specific factors (such as paving, geology, distribution properties of VOCs, depth to water, soil moisture, and the geochemistry of the unsaturated sediments) can affect soil-gas concentrations. Although many soil gas surveys have been undertaken by various investigators at several facilities in the Tutu area, previously conducted soil-gas surveys have had mixed results due to these factors. Therefore, interpretation of the soil-gas survey results requires an understanding of the data and their limitations, as well as knowledge of the site geology. Additional sampling and laboratory analyses of the soil and ground water can confirm the presence and quantify the concentration of VOCs identified by the soil-gas survey. A Photovac 10S50 portable Gas Chromatograph (GC) will be used to determine the presence or absence of VOCs in soil vapor samples collected at the Curriculum Center (former LAGA building) and the VIHA maintenance area. A Photovac 10SSO GC will be used for its ability to separate and quantify selected VOCs. Results can be obtained from the GC within 20 ^^ to 30 minutes. Compound identification and approximate concentrations are provided; however, only those compounds for which the instrument is initially calibrated can be identified and quantified. Therefore, prior to the study, the GC will be calibrated with air standards for GERAGHTY & MILLER, INC. TUT °°6 1293 0 r^ 3 benzene, toluene, xylene, trichloroethene, tetrachloroethene, cis-l,2-dichloroethene, and trans-l,2-dichloroethene. Each of these standards will be prepared by introducing a known volume of the compound into a 1-liter (L) Tedlar bag that has previously been filled with organic-free air. SURVEY GRID The soil-gas survey will be conducted on an unbiased rectilinear grid pattern established initially on a 40-foot spacing. As "hot spots" are encountered, the grid will be reduced to 20- foot spacing, as needed. The survey will be conducted in the areas to the north and west of the Curriculum Center (former) LAGA building. These areas include the former LAGA loading dock area and the area adjacent to the former LAGA dry cleaning room. The survey will also include the areas to the north and west of the VIHA maintenance garage. Areas to be investigated at the Curriculum Center and VIHA maintenance garage are shown on Figure 7-1 '' ' of the Phase n RI Work Plan. The soil-gas survey results will be summarized on a map delineating the approximate areal extent and the concentrations of VOCs detected. This map will be used to evaluate potential sources and to identify optimal locations for monitoring wells at the Curriculum Center and VIHA facilities, as appropriate. A soil-gas "hot spot" is defined, for the purposes of this survey, as a location that has a soil-gas concentration that is an order of magnitude (10 times) greater than surrounding soil- gas values for other locations within the immediate area. The highest soil gas value within a "hot spot" will be identified as the focus for possible further investigation. The exact concentration of soil gas can vary, depending on soil type, initial concentration, soil moisture, and depth to groundwater; therefore, an exact concentration is not useful for determination of hot spots. CALIBRATION f~^ Prior to the initiation of the soil-gas survey, the GC will be calibrated with air standards of site-specific compounds. Standards will be made for each compound by introducing known GERAGHTY • 6 apparatus (i.e., tubing and hose) will be analyzed following every sample where a positive result is obtained. Equipment blanks are collected by removing the sampling assembly from a borehole and running the pump for a few minutes to draw ambient air through the system. An air sample is collected from the stainless-steel equipment and analyzed with the GC. If VOCs are detected in the equipment blank sample, the sampling equipment will be decontaminated by purging the equipment with the sampling pump until the VOCs is no longer detected. QUALITY CONTROL In addition to the calibration analyses, duplicate analyses will be run once every ten samples. Continuing calibration analyses will be performed as required, or a minimum of once every 2 hours, by injecting 300 ul of the standard into the GC. A syringe blank will be run after every calibration check. The retention time of each compound will then be checked for peak drift by comparing the new retention time with the one from the previous standard analysis. 1 A fresh standard will be prepared at the beginning of each day to update the average response factors. PR0013.*«*-WPl/120393.^jp TUT 006 1297 ^ GERAGHTYfi? MILLER, INC. W