ELECTRICAL SYMBOLS LEGEND & NOTES Xx | 1X4 EXISTING LIGHT FIXTURE Sey DUPLEX SWITCH ¢. 21"X21" VENT AT CEILING CAI EXPOSED DUCTING AT CEILING POSSIBLY FOR EX | EXISTING HOOD EXISTING 2X2 ACOUSTICAL TILE EXISTING CEILING MOUNTED LIGHT FIXTURE XOX 2X4 EXISTING LIGHT FIXTURE 2X2 EXISTING LIGHT FIXTURE EX2X2 @) EXISTING DUPLEX OUTLET LOCATED ON WALL EX SURFACE EXISTING FLOOR DRAIN ty EXISTING OUTLET/@ FLOOR EXISTING FIRE EXTINGUISHER ( TO BE UPGRADED BY (Fe) OTHERS DOE COMMERCIAL GRADE FIRE EXTINGUISHERS) | al EXISTING ELECTRICAL PANELS EXISTING FIRE SUPPRESSION SYSTEM ELECTRICAL NOTES /A\ CONTRACTOR TO REMOVE AND REPLACE ANY LIGHT BULBS OR BALLASTS THAT ARE INOPERABLE OR NOT FUNCTIONING PROPERLY. A CONTRACTOR TO VERIFY THAT ALL EXISTING ELECTRICAL PANEL BOXES ARE OPERABLE AND CAP TO CODE ANY PANEL BOXES OR ELECTRICAL LINES THAT ARE NOT BEING USED FOR ANY PART OF THE KITCHEN OR ANY PLACE ELSE ON THE SCHOOL A CONTRACTOR TO REMOVE AND CAP ANY EXISTING FLOOR MOUNTED ELECTRICAL OUTLETS THAT ARE NOT BEING USED BY EXISTING OR NEW ELECTRICAL EQUIPMENT IN THE KITCHEN A\ REMOVE ELECTRICAL PANEL BOX NOTED ON PLAN AND RELOCATE TO WALL NOTED ON THE PLAN UPGRADE PANEL BOX (SEE NOTE 6) AS PER CODE AND EXISTING EQUIPMENT A\ ELECTRICAL PANEL TO REMAIN ON THIS WALL SURFACE CONTRACTOR SHALL VERIFY IF PANEL BOX IS OPERABLE A\ CONTRACTOR TO VERIFY ALL FLOOR MOUNTED DUPLEX OUTLET AND SWITCHES IF NOT REQUIRED FOR NEW KITCHEN EQUIPMENT CONTRACTOR SHALL REMOVE AND OR CAP AS NECESSARY.REPAIR AS REQUIRED IF NOT OPERABLE FOR NEW USAGE CONTRACTOR REMOVE EXISTING LIGHT FIXTURE AND REPLACE WITH SIMLIAR SURFACE MOUNTED FIXTURE CONTRACTOR VERIFY EXISTING EXHAUST HOOD AND EXHAUST HOOD SWITCH IS OPERABLE AND IN COMPLIANCE WITH NFPA CODES . IF NON OPERABLE CONTRACTOR SHALL REPAIR EXISTING EXHAUST HOOD AND SWITCH AND ENSURE IT IS OPERABLE TO ACCOMODATE EQUIPMENT AS PER MANUFACTURER'S SPECIFICATIONS. A\ EXISTING FIRE SUPRESSION SYSTEM TO BE REMOVED AND REPLACED AS SPECIFIED IN ACCORDANCE AND IN COMPLIANCE WITH NFPA CODES AND LOCAL BUILIDING AND FIRE SAFETY CODES. Ad CONTRACTOR SHALL INSPECT ALL DUCT WORK IN THE VINICITY OF THE KITCHEN AND IDENTIFY IF IT IS IN FAVORABLE CONDITION FOR PROPER OPERATION AND NOTIFY ARCHITECT OF EXSITING CONDITION EX EX y tim iy (ail = TT EX-2X4 sD)» ° Tes EX un EX pt EX EX EX EX EX rN I i | EXHAUST H (EXISTING) EX EX EX EX EX EX EX —“ i . a Caribbean % Drofessional Consultants tte (ff 212 BOURNEFIELD 4 LINDBERG BAY, S O Ss P.O.Box 305647 St.Thomas U.S.V.I. 00803 Tel.: 340-774-3357 Boos a REMARKS REVISIONS DATE NO. O O O O — O ep) O Hl O 7p) =) > a) ag z>|c¢ @B - 2|s gq O|tan- > Ig¢gZz e°> EF] arewW O|+s eo =>_/< QO; cas z 2>WO rE| ant my | WORE OQ) ag . - 4%) uit o DRAWN BY: LD CHECKED BY: E. BLAIZE APPROVED BY: F. BLAIZE CONTRACT NO.: CONTRACT.NO. PROJECT NO.: PROJ.NO. DATE: onus UuUUYD ODD ERED AF Cin, f EDMOND Jo gS iss a Bury BLAIZE ee) ey ho 8 B dx Aols Bs &§ x s 3A No.S8i-A iS § Wi ee KS GN ox eo ne2ap 490000 LIGHTING NOTES 2 BCALE 1/4"= 1'-O ~EXISTING LIGHTING LAYOUT SHEET NO.: EX-E1.1 SHEET NO. # OF # SHEETS