solar design associates inc HARVARD, MA 01451-0242 tel: 978-456-6855 fax: 978-772-9715 www.solardesign.com LOVANGO CAY REVISION NOTES MARK DATE DESCRIPTION PROFESSIONAL STAMP THIS DRAWING IS FOR INFORMATION PURPOSES ONLY. CERTIFICATION OR VALIDATION IS TO BE DONE BY A PROFESSIONAL WITH EXPERTISE IN THE REQUIRED FIELD AND A LICENSE IN THE STATE THAT THE INSTALLATION WILL RESIDE. CERTFICIATION OR VALIDATION TO BE INCLUDED AS PART OF THE SUBMITTALS FOR PERMITTING OF THE OVERALL PROJECT. CZM SET Friday, November 22, 2024 CONTRACTOR NAME STREET CITY/ST/ZIP NOTES NAME STREET CITY/ST/ZIP NOTES SITE SUBMISSION PV SITE PLAN PV001 2024-0712 Lovango Cay.pln AS NOTED CW, CS TP SHEET SIZE: DRAWING NO. DRAWING TITLE FILE NAME CHECKED BY DRAWN BY DATE DRAFTED: DRAWING SCALE 11/22/2024 ARCH D ST. JOHN, U.S. VIRGIN ISLANDS 00830 LOVANGO CAY, 1 NOT FOR CONSTRUCTION LOVANGO CAY 5' 1' 1' 1' BATTERY ROOM FUTURE DEPLOYMENT OF MODULES EXISTING UTILITY EQUIPMENT PADS, TYP. PROPERTY LINES EXISTING UNDERGROUND TRENCHING BETWEEN PADS, TYP. EXISTING PV ARRAY A C D E F G J N a b a: 0.00° b: 15.00° CCW CW 1 PV SYSTEM OPTIONS 0 20' 50' 100' PHOTOVOLTAIC SYSTEM FOR LOVANGO CAY LOVANGO CAY, 1, ST. JOHN U.S. VIRGIN ISLANDS 00830 PV System Total Modules Module Wattage kWdc kWac DC/AC Ratio Tilt Azimuth kWh/year kWh/kWdc System A 380 420 159.60 180.00 0.89 15° 180° 283,228 1,775 System A (Expansion) 100 420 42.00 30.00 1.40 15° 180° 70,734 1,684 System C 160 420 67.20 60.00 1.12 15° 148.5° 95,491 1,421 System D 80 420 33.60 30.00 1.12 15° 159° 57,832 1,721 System E 40 420 16.80 30.00 0.56 15° 159° 26,885 1,600 System F 80 420 33.60 30.00 1.12 15° 136.4° 61,330 1,825 System G 59 420 24.78 30.00 0.83 15° 143.8° 39,544 1,596 System J 32.00 30.00 1.07 ~10° ~200.4° 53,573 1,674 SITE TOTAL (No Expansion) 799 420 367.58 390.00 0.94 N/A N/A 617,883 1,681 SITE TOTAL (Incl. Expansion) 899 420 409.58 420.00 0.98 N/A N/A 688,617 1,681 Edward M Portney Digitally signed by Edward M Portney DN: cn=Edward M Portney gn=Edward M Portney c=US United States l=US United States o=Solar Design Associates e=tportney@solardesign.com Reason: I attest to the accuracy and integrity of this document Location: Date: 2024-11-22 11:02-05:00 solar design associates inc HARVARD, MA 01451-0242 tel: 978-456-6855 fax: 978-772-9715 www.solardesign.com LOVANGO CAY REVISION NOTES MARK DATE DESCRIPTION PROFESSIONAL STAMP THIS DRAWING IS FOR INFORMATION PURPOSES ONLY. CERTIFICATION OR VALIDATION IS TO BE DONE BY A PROFESSIONAL WITH EXPERTISE IN THE REQUIRED FIELD AND A LICENSE IN THE STATE THAT THE INSTALLATION WILL RESIDE. CERTFICIATION OR VALIDATION TO BE INCLUDED AS PART OF THE SUBMITTALS FOR PERMITTING OF THE OVERALL PROJECT. CZM SET Friday, November 22, 2024 CONTRACTOR NAME STREET CITY/ST/ZIP NOTES NAME STREET CITY/ST/ZIP NOTES SITE SUBMISSION PV LAYOUT PV101 2024-0712 Lovango Cay.pln AS NOTED CW, CS TP SHEET SIZE: DRAWING NO. DRAWING TITLE FILE NAME CHECKED BY DRAWN BY DATE DRAFTED: DRAWING SCALE 11/22/2024 ARCH D ST. JOHN, U.S. VIRGIN ISLANDS 00830 LOVANGO CAY, 1 NOT FOR CONSTRUCTION LOVANGO CAY 5' 1' 1' 1' EQPT PAD E-16 EQPT PAD E-13 EQPT PAD E-12 EQPT PAD E-7 EQPT PAD E-1 EQPT PAD E-15 BATTERY ROOM FUTURE DEPLOYMENT OF MODULES EXISTING UTILITY EQUIPMENT PADS, TYP. PROPERTY LINES EXISTING UNDERGROUND TRENCHING BETWEEN PADS, TYP. EXISTING PV ARRAY A C D E F G J FUTURE DEPLOYMENT N a b a: 0.00° b: 15.00° CCW CW 1 PV SYSTEM OPTIONS 0 20' 50' 100' PV System Total Modules Module Wattage kWdc kWac DC/AC Ratio Tilt Azimuth kWh/year kWh/kWdc System A 380 420 159.60 180.00 0.89 15° 180° 283,228 1,775 System A (Expansion) 100 420 42.00 30.00 1.40 15° 180° 70,734 1,684 System C 160 420 67.20 60.00 1.12 15° 148.5° 95,491 1,421 System D 80 420 33.60 30.00 1.12 15° 159° 57,832 1,721 System E 40 420 16.80 30.00 0.56 15° 159° 26,885 1,600 System F 80 420 33.60 30.00 1.12 15° 136.4° 61,330 1,825 System G 59 420 24.78 30.00 0.83 15° 143.8° 39,544 1,596 System J 32.00 30.00 1.07 ~10° ~200.4° 53,573 1,674 SITE TOTAL (No Expansion) 799 420 367.58 390.00 0.94 N/A N/A 617,883 1,681 SITE TOTAL (Incl. Expansion) 899 420 409.58 420.00 0.98 N/A N/A 688,617 1,681 solar design associates inc HARVARD, MA 01451-0242 tel: 978-456-6855 fax: 978-772-9715 www.solardesign.com LOVANGO CAY REVISION NOTES MARK DATE DESCRIPTION PROFESSIONAL STAMP THIS DRAWING IS FOR INFORMATION PURPOSES ONLY. CERTIFICATION OR VALIDATION IS TO BE DONE BY A PROFESSIONAL WITH EXPERTISE IN THE REQUIRED FIELD AND A LICENSE IN THE STATE THAT THE INSTALLATION WILL RESIDE. CERTFICIATION OR VALIDATION TO BE INCLUDED AS PART OF THE SUBMITTALS FOR PERMITTING OF THE OVERALL PROJECT. CZM SET Friday, November 22, 2024 CONTRACTOR NAME STREET CITY/ST/ZIP NOTES NAME STREET CITY/ST/ZIP NOTES SITE SUBMISSION DIMENSIONED PV LAYOUT, A & C PV102 2024-0712 Lovango Cay.pln AS NOTED CW, CS TP SHEET SIZE: DRAWING NO. DRAWING TITLE FILE NAME CHECKED BY DRAWN BY DATE DRAFTED: DRAWING SCALE 11/22/2024 ARCH D ST. JOHN, U.S. VIRGIN ISLANDS 00830 LOVANGO CAY, 1 NOT FOR CONSTRUCTION LOVANGO CAY 5'-10 7/8" 4' 5'-10 7/8" 4' 5'-10 7/8" 4' 5'-10 7/8" 4' 5'-10 7/8" 4' 5'-10 7/8" 24'-9 5/8" 35'-3 1/8" 4' 35'-5 1/8" 35'-3 1/8" 4' 70'-8 1/4" 4' 70'-8 1/4" 4' 70'-8 1/4" 35'-1 1/8" FUTURE DEPLOYMENT 70'-8 1/4" 4' 70'-8 1/4" 4' 70'-8 1/4" 4' 70'-8 1/4" N a b a: 0.00° b: 15.00° CCW CW N a b a: 31.28° b: 15.00° CCW CCW 1 DIMENSIONED PV LAYOUT, A 0 8' 16' 32' 2 DIMENSIONED PV LAYOUT, C 0 8' 16' 32' DISTURBED SOIL AREA : 3,340.41 SQFT DISTURBED SOIL AREA : 10,019.26 SQFT NOTE: DISTURBED SOIL AREA REFLECTS THE AREA UNDERNEATH THE MODULES, EXCLUDING THE INTER-ROW SPACING solar design associates inc HARVARD, MA 01451-0242 tel: 978-456-6855 fax: 978-772-9715 www.solardesign.com LOVANGO CAY REVISION NOTES MARK DATE DESCRIPTION PROFESSIONAL STAMP THIS DRAWING IS FOR INFORMATION PURPOSES ONLY. CERTIFICATION OR VALIDATION IS TO BE DONE BY A PROFESSIONAL WITH EXPERTISE IN THE REQUIRED FIELD AND A LICENSE IN THE STATE THAT THE INSTALLATION WILL RESIDE. CERTFICIATION OR VALIDATION TO BE INCLUDED AS PART OF THE SUBMITTALS FOR PERMITTING OF THE OVERALL PROJECT. CZM SET Friday, November 22, 2024 CONTRACTOR NAME STREET CITY/ST/ZIP NOTES NAME STREET CITY/ST/ZIP NOTES SITE SUBMISSION DIMENSIONED PV LAYOUT, D & E PV103 2024-0712 Lovango Cay.pln AS NOTED CW, CS TP SHEET SIZE: DRAWING NO. DRAWING TITLE FILE NAME CHECKED BY DRAWN BY DATE DRAFTED: DRAWING SCALE 11/22/2024 ARCH D ST. JOHN, U.S. VIRGIN ISLANDS 00830 LOVANGO CAY, 1 NOT FOR CONSTRUCTION LOVANGO CAY 5'-10 7/8" 4' 5'-10 7/8" 70'-8 1/4" 4' 70'-8 1/4" 5'-10 7/8" 4' 5'-10 7/8" 70'-8 1/4" N a b a: 20.92° b: 15.00° CCW CCW N a b a: 20.92° b: 15.00° CCW CCW 1 DIMENSIONED PV LAYOUT, D 0 4' 8' 16' 2 DIMENSIONED PV LAYOUT, E 0 4' 8' 16' DISTURBED SOIL AREA : 835.10 SQFT DISTURBED SOIL AREA : 1,670.21 SQFT NOTE: DISTURBED SOIL AREA REFLECTS THE AREA UNDERNEATH THE MODULES, EXCLUDING THE INTER-ROW SPACING solar design associates inc HARVARD, MA 01451-0242 tel: 978-456-6855 fax: 978-772-9715 www.solardesign.com LOVANGO CAY REVISION NOTES MARK DATE DESCRIPTION PROFESSIONAL STAMP THIS DRAWING IS FOR INFORMATION PURPOSES ONLY. CERTIFICATION OR VALIDATION IS TO BE DONE BY A PROFESSIONAL WITH EXPERTISE IN THE REQUIRED FIELD AND A LICENSE IN THE STATE THAT THE INSTALLATION WILL RESIDE. CERTFICIATION OR VALIDATION TO BE INCLUDED AS PART OF THE SUBMITTALS FOR PERMITTING OF THE OVERALL PROJECT. CZM SET Friday, November 22, 2024 CONTRACTOR NAME STREET CITY/ST/ZIP NOTES NAME STREET CITY/ST/ZIP NOTES SITE SUBMISSION DIMENSIONED PV LAYOUT, F & G PV104 2024-0712 Lovango Cay.pln AS NOTED CW, CS TP SHEET SIZE: DRAWING NO. DRAWING TITLE FILE NAME CHECKED BY DRAWN BY DATE DRAFTED: DRAWING SCALE 11/22/2024 ARCH D ST. JOHN, U.S. VIRGIN ISLANDS 00830 LOVANGO CAY, 1 NOT FOR CONSTRUCTION LOVANGO CAY 5'-10 7/8" 4' 5'-10 7/8" 70'-8 1/4" 4' 70'-8 1/4" 5'-10 7/8" 4' 5'-10 7/8" 70'-8 1/4" 4' 31'-8 5/8" 6'-8 3/4" N a b a: 43.61° b: 15.00° CCW CCW N a b a: 36.36° b: 15.00° CCW CCW 1 DIMENSIONED PV LAYOUT, F 0 4' 8' 16' 2 DIMENSIONED LAYOUT, G 0 4' 8' 16' DISTURBED SOIL AREA : 1,670.21 SQFT DISTURBED SOIL AREA : 1,217.83 SQFT NOTE: DISTURBED SOIL AREA REFLECTS THE AREA UNDERNEATH THE MODULES, EXCLUDING THE INTER-ROW SPACING solar design associates inc HARVARD, MA 01451-0242 tel: 978-456-6855 fax: 978-772-9715 www.solardesign.com LOVANGO CAY REVISION NOTES MARK DATE DESCRIPTION PROFESSIONAL STAMP THIS DRAWING IS FOR INFORMATION PURPOSES ONLY. CERTIFICATION OR VALIDATION IS TO BE DONE BY A PROFESSIONAL WITH EXPERTISE IN THE REQUIRED FIELD AND A LICENSE IN THE STATE THAT THE INSTALLATION WILL RESIDE. CERTFICIATION OR VALIDATION TO BE INCLUDED AS PART OF THE SUBMITTALS FOR PERMITTING OF THE OVERALL PROJECT. CZM SET Friday, November 22, 2024 CONTRACTOR NAME STREET CITY/ST/ZIP NOTES NAME STREET CITY/ST/ZIP NOTES SITE SUBMISSION MODULE DETAILS PV202 2024-0712 Lovango Cay.pln AS NOTED CW, CS TP SHEET SIZE: DRAWING NO. DRAWING TITLE FILE NAME CHECKED BY DRAWN BY DATE DRAFTED: DRAWING SCALE 11/22/2024 ARCH D ST. JOHN, U.S. VIRGIN ISLANDS 00830 LOVANGO CAY, 1 NOT FOR CONSTRUCTION LOVANGO CAY MODULE CLIP, TYP, SEE PV201-5 MODULE CLIP FOR HOMRUN WIRES, SUPPORT AT 24" OC MAX ARRANGE CONNECTORS OUT OF DIRECT SUNLIGHT DO NOT EXCEED ALLOWABLE WIRE BEND RADIUS, TYP. THROUGHOUT NORTH / HIGH EDGE SOUTH / LOW EDGE NORTH / HIGH EDGE SOUTH / LOW EDGE NORTH / HIGH EDGE SOUTH / LOW EDGE NORTH / HIGH EDGE SOUTH / LOW EDGE NORTH / HIGH EDGE SOUTH / LOW EDGE NORTH / HIGH EDGE SOUTH / LOW EDGE NORTH / HIGH EDGE SOUTH / LOW EDGE STAINLESS STEEL CABLE CLIP TO HOLD UP TO TWO WIRES (HEYCO HEYCLIP SUNRUNNER OR EQUIV.) PV WIRE MODULE CABLE TOOTH BITES INTO MODULE FRAME TO SECURE CLIP STAINLESS STEEL CABLE CLIP (HEYCO SUNRUNNER OR EQUIV.) PVC COATED METAL WIRE TIE (HEYCO SUNBUNDLER OR EQUIV.) GROUP OF 2+ HOMERUN WIRES 3'-11 1/4" 6'-1 3/8" 3'-4 1/2" 3'-11 1/4" GROUNDING HOLE, 4.2mm DIA., TYP OF 2 MOUNTING HOLE, 12mm x 7.0mm, TYP OF 4 1 TYPICAL SOURCE CIRCUIT WIRING 0 6'' 1' 2' 3 2-WIRE MODULE CLIP 0 1/2'' 1'' 2'' 4 HOMERUN WIRING CLIP 0 1/2'' 1'' 2'' 2 MODULE DETAILS 0 6'' 12'' 18'' solar design associates inc HARVARD, MA 01451-0242 tel: 978-456-6855 fax: 978-772-9715 www.solardesign.com LOVANGO CAY REVISION NOTES MARK DATE DESCRIPTION PROFESSIONAL STAMP THIS DRAWING IS FOR INFORMATION PURPOSES ONLY. CERTIFICATION OR VALIDATION IS TO BE DONE BY A PROFESSIONAL WITH EXPERTISE IN THE REQUIRED FIELD AND A LICENSE IN THE STATE THAT THE INSTALLATION WILL RESIDE. CERTFICIATION OR VALIDATION TO BE INCLUDED AS PART OF THE SUBMITTALS FOR PERMITTING OF THE OVERALL PROJECT. CZM SET Friday, November 22, 2024 CONTRACTOR NAME STREET CITY/ST/ZIP NOTES NAME STREET CITY/ST/ZIP NOTES SITE SUBMISSION RACKING DETAILS PV203 2024-0712 Lovango Cay.pln AS NOTED CW, CS TP SHEET SIZE: DRAWING NO. DRAWING TITLE FILE NAME CHECKED BY DRAWN BY DATE DRAFTED: DRAWING SCALE 11/22/2024 ARCH D ST. JOHN, U.S. VIRGIN ISLANDS 00830 LOVANGO CAY, 1 NOT FOR CONSTRUCTION LOVANGO CAY IR-F2 BRACKET, TYP OF 4 PER MODULE 1" EMT CONDUIT IR-15 HIGH LEG BALLAST OMITTED FOR CLARITY 6'-1 3/8" 2'-8 7/8" 1'-1 7/8" 2'-4" 1'-6" 1'-4" SILFAB 420W PV MODULE GRAVEL BALLAST, MIN. 700LBS PER MODULE GEOTEXTILE MATERIAL UNDER BALLAST 1" EMT CONDUIT ACROSS RACKING 15° 2 RACKING DETAILS - ELEVATION VIEW FROM BEHIND MODULES 0 6'' 12'' 18'' 1 RACKING DETAILS - SIDE VIEW 0 6'' 12'' 18'' NOTES: 1. GRAVEL BALLAST TO BE A MINIMUM OF 700LBS PER MODULE. DENSITY OF GRAVEL BALLAST AS SHOWN IS ~14LBS/GALLON. DENSITY TO BE MEASURED ON SITE. SQUARE FOOTAGE OF DISTURBED SOIL PER INDIVIDUAL RACKING UNIT : 20.35 SQFT solar design associates inc HARVARD, MA 01451-0242 tel: 978-456-6855 fax: 978-772-9715 www.solardesign.com LOVANGO CAY REVISION NOTES MARK DATE DESCRIPTION PROFESSIONAL STAMP THIS DRAWING IS FOR INFORMATION PURPOSES ONLY. CERTIFICATION OR VALIDATION IS TO BE DONE BY A PROFESSIONAL WITH EXPERTISE IN THE REQUIRED FIELD AND A LICENSE IN THE STATE THAT THE INSTALLATION WILL RESIDE. CERTFICIATION OR VALIDATION TO BE INCLUDED AS PART OF THE SUBMITTALS FOR PERMITTING OF THE OVERALL PROJECT. CZM SET Friday, November 22, 2024 CONTRACTOR NAME STREET CITY/ST/ZIP NOTES NAME STREET CITY/ST/ZIP NOTES SITE SUBMISSION RACKING ELEVATION, SYSTEM A PV204 2024-0712 Lovango Cay.pln AS NOTED CW, CS TP SHEET SIZE: DRAWING NO. DRAWING TITLE FILE NAME CHECKED BY DRAWN BY DATE DRAFTED: DRAWING SCALE 11/22/2024 ARCH D ST. JOHN, U.S. VIRGIN ISLANDS 00830 LOVANGO CAY, 1 NOT FOR CONSTRUCTION LOVANGO CAY 5'-6" 4' ~2' AVERAGE 9'-11 1/4" AVERAGE TERRAIN SLOPE TERRAIN REMOVED FOR PV MODULES, WILL VARY ACROSS ROWS 140 150 160 170 180 180 ELEVATION ABOVE SEA LEVEL (FT) MAJOR CONTOUR LINE (10') MINOR CONTOUR LINE (2') 2 ELEVATION VIEW, SYSTEM A 0 1' 2' 3' 1 TOPOGRAPHIC LAYOUT, SYSTEM A 0 10' 20' 40' NOTE: ABOVE LAYOUT SHOWS AVERAGE SLOPE OF 14.93° ACROSS THE ARRAY. SLOPE TO VARY PER TOPOGRAPHIC LAYOUT SHOWN IN 204.1 AND PER FIELD CONDITIONS solar design associates inc HARVARD, MA 01451-0242 tel: 978-456-6855 fax: 978-772-9715 www.solardesign.com LOVANGO CAY REVISION NOTES MARK DATE DESCRIPTION PROFESSIONAL STAMP THIS DRAWING IS FOR INFORMATION PURPOSES ONLY. CERTIFICATION OR VALIDATION IS TO BE DONE BY A PROFESSIONAL WITH EXPERTISE IN THE REQUIRED FIELD AND A LICENSE IN THE STATE THAT THE INSTALLATION WILL RESIDE. CERTFICIATION OR VALIDATION TO BE INCLUDED AS PART OF THE SUBMITTALS FOR PERMITTING OF THE OVERALL PROJECT. CZM SET Friday, November 22, 2024 CONTRACTOR NAME STREET CITY/ST/ZIP NOTES NAME STREET CITY/ST/ZIP NOTES SITE SUBMISSION BESS EQUIPMENT PV502 2024-0712 Lovango Cay.pln AS NOTED CW, CS TP SHEET SIZE: DRAWING NO. DRAWING TITLE FILE NAME CHECKED BY DRAWN BY DATE DRAFTED: DRAWING SCALE 11/22/2024 ARCH D ST. JOHN, U.S. VIRGIN ISLANDS 00830 LOVANGO CAY, 1 NOT FOR CONSTRUCTION LOVANGO CAY 1'-11 3/4" 17'-6 1/4" 1' 17'-6 1/4" 40' 7'-6 7/8" CONTROL CABINET FUTURE BESS DEPLOYMENT 373 kWh 373 kWh 373 kWh 13' 5'-9 3/4" 4'-2 1/4" 3' 3' 17'-4 1/4" 1' 17'-4 1/4" 3' 41'-8 5/8" 3' MINIMUM REQUIRED WORKING SPACE MINIMUM REQUIRED CLEARENCE SPACE PER BATTERY MANUFACTURER 3 QTY BESS INVERTERS FUTURE BESS DEPLOYMENT FUTURE BESS DEPLOYMENT 1 BESS ELEVATION 0 1' 2' 3' 2 BESS LAYOUT 0 1' 2' 4' solar design associates inc HARVARD, MA 01451-0242 tel: 978-456-6855 fax: 978-772-9715 www.solardesign.com LOVANGO CAY REVISION NOTES MARK DATE DESCRIPTION PROFESSIONAL STAMP THIS DRAWING IS FOR INFORMATION PURPOSES ONLY. CERTIFICATION OR VALIDATION IS TO BE DONE BY A PROFESSIONAL WITH EXPERTISE IN THE REQUIRED FIELD AND A LICENSE IN THE STATE THAT THE INSTALLATION WILL RESIDE. CERTFICIATION OR VALIDATION TO BE INCLUDED AS PART OF THE SUBMITTALS FOR PERMITTING OF THE OVERALL PROJECT. CZM SET Friday, November 22, 2024 CONTRACTOR NAME STREET CITY/ST/ZIP NOTES NAME STREET CITY/ST/ZIP NOTES SITE SUBMISSION SINGLE LINE, OVERALL PV601 2024-0712 Lovango Cay.pln AS NOTED CW, CS TP SHEET SIZE: DRAWING NO. DRAWING TITLE FILE NAME CHECKED BY DRAWN BY DATE DRAFTED: DRAWING SCALE 11/22/2024 ARCH D ST. JOHN, U.S. VIRGIN ISLANDS 00830 LOVANGO CAY, 1 NOT FOR CONSTRUCTION LOVANGO CAY EXISTING ELECTRICAL INFRASTRUCTURE EQUIPMENT SHOWN IN GRAY. PAD E1 "STEP UP TRANSFORMER" 500kVA 3PH TO GENERATORS, PV SYSTEM J PAD E2 "LOT O" TAP BOX TAP BOX (POWER) TAP BOX (DATA) PAD E4 "L-HOUSE PAD" 150kVA 3PH 50kVA 1PH PAD E3 "VILLA" PAD E5 "BURN PILE" TAP BOX 75kVA 1PH PAD E6 "IN GROUND BY QUONSET" PULL BOX PAD E7 "GWENN LOT" TO PV SYSTEM A 75kVA 1PH PAD E8 "NORTH #1" 75kVA 1PH 50kVA 1PH PULL BOX TO CRESCENT BEACH & FUTURE EXPANSION PAD E9 "NORTH #2" PAD E18 "FOUR CORNERS" TAP BOX PAD E17 FUTURE PAD PAD E16 FUTURE PAD PAD E11 "COTTAGE" TAP BOX PAD E12 "COTTAGE #2" PAD E13 "COTTAGE #3" PAD E14 FUTURE PAD E10 "LOBBY TENT" TBD TBD TBD TAP BOX TAP BOX TO PV SYSTEM "EASTERN BLOCK" PAD E15 FUTURE PAD TBD TAP BOX 500kVA 3PH TO BESS 225kVA 3PH 300kVA 3PH 1 MV LOOP SINGLE LINE solar design associates inc HARVARD, MA 01451-0242 tel: 978-456-6855 fax: 978-772-9715 www.solardesign.com LOVANGO CAY REVISION NOTES MARK DATE DESCRIPTION PROFESSIONAL STAMP THIS DRAWING IS FOR INFORMATION PURPOSES ONLY. CERTIFICATION OR VALIDATION IS TO BE DONE BY A PROFESSIONAL WITH EXPERTISE IN THE REQUIRED FIELD AND A LICENSE IN THE STATE THAT THE INSTALLATION WILL RESIDE. CERTFICIATION OR VALIDATION TO BE INCLUDED AS PART OF THE SUBMITTALS FOR PERMITTING OF THE OVERALL PROJECT. CZM SET Friday, November 22, 2024 CONTRACTOR NAME STREET CITY/ST/ZIP NOTES NAME STREET CITY/ST/ZIP NOTES SITE SUBMISSION SINGLE LINE, SYSTEM A PV602 2024-0712 Lovango Cay.pln AS NOTED CW, CS TP SHEET SIZE: DRAWING NO. DRAWING TITLE FILE NAME CHECKED BY DRAWN BY DATE DRAFTED: DRAWING SCALE 11/22/2024 ARCH D ST. JOHN, U.S. VIRGIN ISLANDS 00830 LOVANGO CAY, 1 NOT FOR CONSTRUCTION LOVANGO CAY (A) TABLE 1: PHOTOVOLTAIC SYSTEM EQUIPMENT LIST SILFAB 420W PV MODULE, SIL-420 BG TRANSIENT VOLTAGE SURGE SUPPRESSOR INTEGRATED INTO PANEL, 120kA MINIMUM RATING (D) 1 PV PANELBOARD, 277/480V, 400A BUSBAR WITH 300A MAIN BREAKER, BRANCH BREAKERS AS NOTED, NEMA3R (C) 1 TABLE 2: TRIP LEVEL SETTINGS TO STOP INVERTER 0.16 SEC LINE UNDER FREQUENCY (SLOW) 2.0 SEC LINE UNDER FREQUENCY (FAST) ID 3.0 SEC 6 56.5 Hz 58.5 Hz 4 5 TOTAL CLEAR TIME 0.16 SEC 62.0 Hz LINE OVER FREQUENCY (FAST) 304.7 V 243.7 V LINE OVER VOLTAGE (FAST) 1 2 300 SEC 61.2 Hz LINE OVER FREQUENCY (SLOW) 332.4 V 300 SEC 0.16 SEC 59.5 ≤ f ≤ 60.5 263.1 ≤ V ≤ 290.8V 8 DESCRIPTION LINE UNDER VOLTAGE (SLOW) SET POINT 7 LINE OVER VOLTAGE (SLOW) 138.5 V VNOM = 277V L-N 1.1 SEC LINE UNDER VOLTAGE (FAST) 300 SEC UTILITY RESTORATION DETECTION 9 3 (B1) 6 SMA SUNNY TRIPOWER 30-US STP-30-US-50 INVERTER, 30kW, 36Aac MAX OUTPUT CURRENT, 277/480Vac OUTPUT, WITH SMA SENSOR MODULE FOR WEATHER STATION DATA INTERFACING GENERAL EQUIPMENT NOTES: 1. ALL EQUIPMENT TO BE RATED FOR USE AS SERVICE ENTRANCE EQUIPMENT. NEW UTILITY OWNED 225kVA PAD MOUNTED TRANSFORMER, 277/480VAC Yg SECONDARY, 2.40/4.16kV Yg PRIMARY 1 (E) (B2) MAINTENANCE AC DISCONNECT, 277/480V , MIN 50A, 3- POLE, NEMA3R OR NEMA4X, ABB-EOT45U3P4-P OR EQUIV. 6 WEATHER STATION IN ARRAY FIELD 1 (F) (A) INV A1 30 kW MPPT-1 MPPT-2 SYSTEM A 159.60 kWdc 380 PV MODULES MPPT-3 (B1) MPPT-3 MPPT-2 MPPT-1 INV A6 30 kW [...] (B2) [...] INV A2 THRU INV A5 NOT SHOWN (B2) (B1) 15A 3P TVSS (C) 277/480V, 400A BUS, 3P/4W PV-PANEL-A 60A 3P 60A 3P (D) G N MEDIA CONVERTER (H) TO OTHER PV/GEN/BATTERY 350A 3P 277/480V (E) 4.16kV 225 kVA TO MEDIUM VOLTAGE LOOP (PAD E7) SITE CONDITIONS LOCATION: LOVANGO CAY, US V.I. MAX AVG TEMP: 35 °C MIN EXPECTED TEMP: 16 °C PV ARRAY CONFIGURATION Manufacturer: SILFAB SOLAR Model: SIL-420 BG Module Qty: 380 Total series strings: 20 PV MODULE OUTPUT* Voc: 46.36 Vdc Voc Temp Coeff. -0.279 %/ °C Voc (Temp Adjusted) 48.82 Vdc Isc: 11.40 Adc Vmp: 38.51 Vdc Imp: 10.91 Adc 20 MODULE SOURCE CIRCUIT OUTPUT* Voc: 867.20 Vdc Voc (Temp Adjusted) 976.80 Vdc Isc: 11.40 Adc Vmp: 770.20 Vdc Imp: 10.91 Adc *BASED ON MODULE PERFORMANCE AT STANDARD TEST CONDITIONS (STC) PV INVERTER OUTPUT (SMA STP-30-US-50) Nominal Power: 30.0 kWac Max Apparent Power: 30.0 kVA Operating Voltage (Line-to-Line): 480 Vac 3-Phase Max Current: 36 Aac Output Frequency: 60 Hz TRANSFORMER OUTPUT (225 kVA) Max Rated Power 225 kVA Primary Voltage: 4,160 Vac L-L Secondary Voltage: 480 Vac Output Current: 24.92 Aac INVERTER TRIP LEVEL NOTES: 1. INVERTER TOTAL CLEARING TIME INCLUDES MECHANICAL OPERATION TIME OF 3 CYCLES (0.05s) 2. UTILITY RESTORATION DETECTION WILL USE THE FACTORY SETTINGS FOR A UL 1741SB CERTIFIED INVERTER. 60A 3P 60A 3P 60A 3P 60A 3P MPPT-3 MPPT-2 MPPT-1 INV 30 kW SPARE 3P FOR FUTURE DEPLOYMENT FUTURE DEPLOYMENT 42.00 kWdc 100 PV MODULES 480 1 1 7 1 1 7 380 QTY QTY* *REFLECTS TOTAL QUANTITY AFTER FUTURE DEPLOYMENT 1 180.00 kWac, 159.60 kWdc PV SINGLE LINE - SYSTEM A solar design associates inc HARVARD, MA 01451-0242 tel: 978-456-6855 fax: 978-772-9715 www.solardesign.com LOVANGO CAY REVISION NOTES MARK DATE DESCRIPTION PROFESSIONAL STAMP THIS DRAWING IS FOR INFORMATION PURPOSES ONLY. CERTIFICATION OR VALIDATION IS TO BE DONE BY A PROFESSIONAL WITH EXPERTISE IN THE REQUIRED FIELD AND A LICENSE IN THE STATE THAT THE INSTALLATION WILL RESIDE. CERTFICIATION OR VALIDATION TO BE INCLUDED AS PART OF THE SUBMITTALS FOR PERMITTING OF THE OVERALL PROJECT. CZM SET Friday, November 22, 2024 CONTRACTOR NAME STREET CITY/ST/ZIP NOTES NAME STREET CITY/ST/ZIP NOTES SITE SUBMISSION SINGLE LINE, EASTERN BLOCK PV603 2024-0712 Lovango Cay.pln AS NOTED CW, CS TP SHEET SIZE: DRAWING NO. DRAWING TITLE FILE NAME CHECKED BY DRAWN BY DATE DRAFTED: DRAWING SCALE 11/22/2024 ARCH D ST. JOHN, U.S. VIRGIN ISLANDS 00830 LOVANGO CAY, 1 NOT FOR CONSTRUCTION LOVANGO CAY (A) INV C1 30 kW MPPT-1 MPPT-2 SYSTEM C 27.20 kWdc 160 PV MODULES MPPT-3 (B1) MPPT-3 MPPT-2 MPPT-1 INV C2 30 kW (B2) (B2) (B1) 15A 3P TVSS (C) 277/480V, 400A BUS, 3P/4W PV-PANEL 60A 3P (D) G N TO OTHER PV/GEN/BATTERY 400A 3P 277/480V (F) 4.16kV 300 kVA TO MEDIUM VOLTAGE LOOP (PAD E15) (A) INV D1 30 kW MPPT-1 MPPT-2 SYSTEM D 33.60 kWdc 80 PV MODULES MPPT-3 (B1) (B2) 60A 3P (A) INV E1 30 kW MPPT-1 MPPT-2 SYSTEM E 16.80 kWdc 40 PV MODULES MPPT-3 (B1) (B2) 60A 3P INV F1 30 kW MPPT-1 MPPT-2 SYSTEM F 33.60 kWdc 80 PV MODULES MPPT-3 (B1) (B2) 60A 3P 60A 3P (A) (A) INV G1 30 kW MPPT-1 MPPT-2 SYSTEM G 24.78 kWdc 59 PV MODULES MPPT-3 (B1) (B2) 60A 3P GENERAL EQUIPMENT NOTES: 1. ALL EQUIPMENT TO BE RATED FOR USE AS SERVICE ENTRANCE EQUIPMENT. 3 9 UTILITY RESTORATION DETECTION 300 SEC 59.5 ≤ f ≤ 60.5 0.16 SEC 300 SEC LINE UNDER VOLTAGE (FAST) 332.4 V LINE OVER FREQUENCY (SLOW) 1.1 SEC VNOM = 277V L-N 138.5 V LINE OVER VOLTAGE (SLOW) 61.2 Hz 300 SEC (A) TABLE 1: PHOTOVOLTAIC SYSTEM EQUIPMENT LIST 419 7 2 SILFAB 420W PV MODULE, SIL-420 BG SET POINT LINE UNDER VOLTAGE (SLOW) DESCRIPTION 8 263.1 ≤ V ≤ 290.8V TRANSIENT VOLTAGE SURGE SUPPRESSOR INTEGRATED INTO PANEL, 120kA MINIMUM RATING (D) 1 PV PANELBOARD, 277/480V, 60A BUSBAR WITH 60A MAIN BREAKER, BRANCH BREAKERS AS NOTED, NEMA3R (C) 1 INVERTER TRIP LEVEL NOTES: 1. INVERTER TOTAL CLEARING TIME INCLUDES MECHANICAL OPERATION TIME OF 3 CYCLES (0.05s) 2. UTILITY RESTORATION DETECTION WILL USE THE FACTORY SETTINGS FOR A UL 1741SB CERTIFIED INVERTER. TABLE 2: TRIP LEVEL SETTINGS TO STOP INVERTER 0.16 SEC LINE UNDER FREQUENCY (SLOW) 2.0 SEC LINE UNDER FREQUENCY (FAST) ID 3.0 SEC 6 56.5 Hz 58.5 Hz 4 5 TOTAL CLEAR TIME 0.16 SEC 62.0 Hz LINE OVER FREQUENCY (FAST) 304.7 V 243.7 V LINE OVER VOLTAGE (FAST) 1 (B1) 6 SMA SUNNY TRIPOWER 30-US STP-30-US-50 INVERTER, 30kW, 36Aac MAX OUTPUT CURRENT, 277/480Vac OUTPUT (E) 1 WEATHER STATION IN ARRAY FIELD 6 MAINTENANCE AC DISCONNECT, 277/480V , MIN 50A, 3- POLE, NEMA3R OR NEMA4X, ABB-EOT45U3P4-P OR EQUIV. (B2) SITE CONDITIONS LOCATION: LOVANGO CAY, US V.I. MAX AVG TEMP: 35 °C MIN EXPECTED TEMP: 16 °C PV ARRAY CONFIGURATION Manufacturer: SILFAB SOLAR Model: SIL-420 BG Module Qty: 419 Total series strings: 21 PV MODULE OUTPUT* Voc: 46.36 Vdc Voc Temp Coeff. -0.279 %/ °C Voc (Temp Adjusted) 48.82 Vdc Isc: 11.40 Adc Vmp: 38.51 Vdc Imp: 10.91 Adc 19 MODULE SOURCE CIRCUIT OUTPUT* Voc: 880.84 Vdc Voc (Temp Adjusted) 927.58 Vdc Isc: 11.40 Adc Vmp: 731.69 Vdc Imp: 10.91 Adc 20 MODULE SOURCE CIRCUIT OUTPUT* Voc: 927.20 Vdc Voc (Temp Adjusted) 976.40 Vdc Isc: 11.40 Adc Vmp: 770.20 Vdc Imp: 10.91 Adc *BASED ON MODULE PERFORMANCE AT STANDARD TEST CONDITIONS (STC) PV INVERTER OUTPUT (SMA STP-30-US-50) Nominal Power: 30.0 kWac Max Apparent Power: 30.0 kVA Operating Voltage (Line-to-Line): 480 Vac 3-Phase Max Current: 36 Aac Output Frequency: 60 Hz TRANSFORMER OUTPUT (300 kVA) Max Rated Power 300 kVA Primary Voltage: 4,160 Vac L-L Secondary Voltage: 480 Vac Output Current: 199.38 Aac (F) NEW UTILITY OWNED 300kVA PAD MOUNTED TRANSFORMER, 277/480VAC Yg SECONDARY, 2.40/4.16kV Yg PRIMARY 1 *REFLECTS TOTAL QUANTITY AFTER FUTURE DEPLOYMENT QTY MEDIA CONVERTER (E) 1 180.00 kWac (175.98 kWdc) PV SINGLE LINE solar design associates inc HARVARD, MA 01451-0242 tel: 978-456-6855 fax: 978-772-9715 www.solardesign.com LOVANGO CAY REVISION NOTES MARK DATE DESCRIPTION PROFESSIONAL STAMP THIS DRAWING IS FOR INFORMATION PURPOSES ONLY. CERTIFICATION OR VALIDATION IS TO BE DONE BY A PROFESSIONAL WITH EXPERTISE IN THE REQUIRED FIELD AND A LICENSE IN THE STATE THAT THE INSTALLATION WILL RESIDE. CERTFICIATION OR VALIDATION TO BE INCLUDED AS PART OF THE SUBMITTALS FOR PERMITTING OF THE OVERALL PROJECT. CZM SET Friday, November 22, 2024 CONTRACTOR NAME STREET CITY/ST/ZIP NOTES NAME STREET CITY/ST/ZIP NOTES SITE SUBMISSION SINGLE LINE, GEN, BATTERY PV604 2024-0712 Lovango Cay.pln AS NOTED CW, CS TP SHEET SIZE: DRAWING NO. DRAWING TITLE FILE NAME CHECKED BY DRAWN BY DATE DRAFTED: DRAWING SCALE 11/22/2024 ARCH D ST. JOHN, U.S. VIRGIN ISLANDS 00830 LOVANGO CAY, 1 NOT FOR CONSTRUCTION LOVANGO CAY (A1) 400A 3P 250 kW / 312.5 kVA 60Hz 277/480V G (B) (A2) 300A 3P 200 kW / 250 kVA 60Hz 277/480V G (B) 15A 3P TVSS (C) (D) G N 800A 3P 400A 3P 300A 3P 277/480V, 800A BUS, 3P/4W GRID FORMING PANEL AGC-150 GENERATOR CONTROLLER TO SYSTEM CONTROL POINT 277/480V (E) 4.16kV 500 kVA TO MEDIUM VOLTAGE LOOP (PAD E1) GENERAL EQUIPMENT NOTES: 1. ALL EQUIPMENT TO BE RATED FOR USE AS SERVICE ENTRANCE EQUIPMENT. TABLE 1: PHOTOVOLTAIC SYSTEM EQUIPMENT LIST AGC-150 GENERATOR CONTROLLER 1 (F) TRANSIENT VOLTAGE SURGE SUPPRESSOR INTEGRATED INTO PANEL, 120kA MINIMUM RATING (D) 1 250kW, 312.5 kVA GRID FORMING GENERATOR, 277/480V OUTPUT, 3P/4W, 300A MAXIMUM OUTPUT CURRENT (A1) 1 (E) NEW UTILITY OWNED 300kVA PAD MOUNTED TRANSFORMER, 277/480VAC Yg SECONDARY, 2.40/4.16kV Yg PRIMARY 1 SITE CONDITIONS LOCATION: LOVANGO CAY, US V.I. MAX AVG TEMP: 35 °C MIN EXPECTED TEMP: 16 °C BESS INVERTER OUTPUT (EPC PD250/AC-480 250kW) Nominal Power: 250.00 kWac Max Apparent Power: 250.00 kVA Operating Voltage (Line-to-Line): 480 Vac 3-Phase Max Current: 300.7 Aac Output Frequency: 60 Hz TRANSFORMER OUTPUT (300 kVA) Max Rated Power 300 kVA Primary Voltage: 4,160 Vac L-L Secondary Voltage: 480 Vac Output Current: 41.64 Aac (C) 1 1 (B) GRID FORMING PANELBOARD, 800A BUS, 800A MAIN BREAKER, 3P/4W, BRANCH BREAKERS AS NOTED, NEMA 3R GENERATOR CONTACTOR, 277/480Vac 3 POLE, 400A MIN RATING, SIGNAL FROM GENERATOR CONTROLLER (F) 400A 3P TO EXISTING 400A MDP 60A 3P TO PV SYSTEM J 200kW, 250 kVA GRID FORMING GENERATOR, 277/480V OUTPUT, 3P/4W, 240A MAXIMUM OUTPUT CURRENT (A2) 1 (B) INV B1 125 kW 200A 3P 373 kWhr 15A 3P TVSS (F) 200A 3P (G) G N 600A 3P 200A 3P 277/480V, 600A BUS, 3P/4W GRID FORMING PANEL TO SYSTEM CONTROL POINT 277/480V (H) 4.16kV 500 kVA TO MEDIUM VOLTAGE LOOP (PAD E1) (A) (I) GENERAL EQUIPMENT NOTES: 1. ALL EQUIPMENT TO BE RATED FOR USE AS SERVICE ENTRANCE EQUIPMENT. TABLE 1: PHOTOVOLTAIC SYSTEM EQUIPMENT LIST UTILITY MICROGRID CONTROLLER 1 (I) TRANSIENT VOLTAGE SURGE SUPPRESSOR INTEGRATED INTO PANEL, 120kA MINIMUM RATING (G) 1 (B) 1 DYNAPOWER MPS125kW INVERTER, 125kW, 150.0Aac MAX OUTPUT CURRENT, 480Vac OUTPUT (H) NEW UTILITY OWNED 300kVA PAD MOUNTED TRANSFORMER, 480VAC D SECONDARY, 2.40/4.16kV Yg PRIMARY 1 SITE CONDITIONS LOCATION: LOVANGO CAY, US V.I. MAX AVG TEMP: 35 °C MIN EXPECTED TEMP: 16 °C BESS INVERTER OUTPUT (MPS-125) Nominal Power: 125.0 kWac Max Apparent Power: 125.00 kVA Operating Voltage (Line-to-Line): 480 Vac 3-Phase Max Current: 150.0 Aac Output Frequency: 60 Hz TRANSFORMER OUTPUT (500 kVA) Max Rated Power 500 kVA Primary Voltage: 4,160 Vac L-L Secondary Voltage: 480 Vac Output Current: 34.62 Aac (F) 1 GRID FORMING PANELBOARD, 600A BUS, 600A MAIN BREAKER, 3P/4W, BRANCH BREAKERS AS NOTED, NEMA 3R (A) 1 BATTERY ENCLOSURE, 1000 kWhr OF BATTERY STORAGE (4hr RUNTIME MIN), NEMA 3R INVERTER TRIP LEVEL NOTES: 1. INVERTER TOTAL CLEARING TIME INCLUDES MECHANICAL OPERATION TIME OF 3 CYCLES (0.05s) 2. UTILITY RESTORATION DETECTION WILL USE THE FACTORY SETTINGS FOR A UL 1741SB CERTIFIED INVERTER. 1 LINE OVER VOLTAGE (FAST) 243.7 V 304.7 V LINE OVER FREQUENCY (FAST) 62.0 Hz 0.16 SEC TOTAL CLEAR TIME 5 4 58.5 Hz 56.5 Hz 6 3.0 SEC ID LINE UNDER FREQUENCY (FAST) 2.0 SEC LINE UNDER FREQUENCY (SLOW) 0.16 SEC TABLE 2: TRIP LEVEL SETTINGS TO STOP INVERTER 263.1 ≤ V ≤ 290.8V 8 DESCRIPTION LINE UNDER VOLTAGE (SLOW) SET POINT 2 7 300 SEC 61.2 Hz LINE OVER VOLTAGE (SLOW) 138.5 V VNOM = 277V L-N 1.1 SEC LINE OVER FREQUENCY (SLOW) 332.4 V LINE UNDER VOLTAGE (FAST) 300 SEC 0.16 SEC 59.5 ≤ f ≤ 60.5 300 SEC UTILITY RESTORATION DETECTION 9 3 (B) INV B2 125 kW 200A 3P 373 kWhr (A) 200A 3P (B) INV B2 125 kW 200A 3P 373 kWhr (A) ASC-150 STORAGE CONTROLLER (D1) 400A 3P 250 kW / 312.5 kVA 60Hz 277/480V G (E) (D2) 300A 3P 200 kW / 250 kVA 60Hz 277/480V G (E) 15A 3P TVSS (F2) 600A 3P (G) G N 800A 3P 400A 3P 300A 3P TO INTERNET 277/480V (H) 4.16kV 500 kVA TO MEDIUM VOLTAGE LOOP (PAD E1) 3 9 UTILITY RESTORATION DETECTION 300 SEC 59.5 ≤ f ≤ 60.5 0.16 SEC 300 SEC LINE UNDER VOLTAGE (FAST) 332.4 V LINE OVER FREQUENCY (SLOW) 1.1 SEC VNOM = 277V L-N 138.5 V LINE OVER VOLTAGE (SLOW) 61.2 Hz 300 SEC 7 2 SET POINT LINE UNDER VOLTAGE (SLOW) DESCRIPTION 8 263.1 ≤ V ≤ 290.8V TABLE 2: TRIP LEVEL SETTINGS TO STOP INVERTER 0.16 SEC LINE UNDER FREQUENCY (SLOW) 2.0 SEC LINE UNDER FREQUENCY (FAST) ID 3.0 SEC 6 56.5 Hz 58.5 Hz 4 5 TOTAL CLEAR TIME 0.16 SEC 62.0 Hz LINE OVER FREQUENCY (FAST) 304.7 V 243.7 V LINE OVER VOLTAGE (FAST) 1 INVERTER TRIP LEVEL NOTES: 1. INVERTER TOTAL CLEARING TIME INCLUDES MECHANICAL OPERATION TIME OF 3 CYCLES (0.05s) 2. UTILITY RESTORATION DETECTION WILL USE THE FACTORY SETTINGS FOR A UL 1741SB CERTIFIED INVERTER. GENERAL EQUIPMENT NOTES: 1. ALL EQUIPMENT TO BE RATED FOR USE AS SERVICE ENTRANCE EQUIPMENT. TABLE 1: PHOTOVOLTAIC SYSTEM EQUIPMENT LIST TRANSIENT VOLTAGE SURGE SUPPRESSOR INTEGRATED INTO PANEL, 120kA MINIMUM RATING (G) 1 250kW, 312.5 kVA GRID FORMING GENERATOR, 277/480V OUTPUT, 3P/4W, 300A MAXIMUM OUTPUT CURRENT (D1) 1 (B) 2 (H) NEW UTILITY OWNED 500kVA PAD MOUNTED TRANSFORMER, 277/480VAC Yg SECONDARY, 2.40/4.16kV Yg PRIMARY 1 1 BESS ISOLATION TRANSFORMER, 250kVA, 480Vac D TO 277/480 WYE, NEMA3R (C) SITE CONDITIONS LOCATION: LOVANGO CAY, US V.I. MAX AVG TEMP: 35 °C MIN EXPECTED TEMP: 16 °C BESS INVERTER OUTPUT (MPS-125) Nominal Power: 125.0 kWac Max Apparent Power: 125.00 kVA Operating Voltage (Line-to-Line): 480 Vac 3-Phase Max Current: 150.0 Aac Output Frequency: 60 Hz TRANSFORMER OUTPUT (300 kVA) Max Rated Power 300 kVA Primary Voltage: 4,160 Vac L-L Secondary Voltage: 480 Vac Output Current: 41.64 Aac (F2) 1 1 (E) GRID FORMING PANELBOARD, 800A BUS, 800A MAIN BREAKER, 3P/4W, BRANCH BREAKERS AS NOTED, NEMA 3R (A) 1 BATTERY ENCLOSURE, 1000 kWhr OF BATTERY STORAGE TOTAL (4hr RUNTIME MIN), NEMA 3R GENERATOR CONTACTOR, 277/480Vac 3 POLE, 400A MIN RATING, SIGNAL FROM GENERATOR CONTROLLER 400A 3P TO EXISTING 400A MDP 60A 3P TO PV SYSTEM J (B) INV B1 125 kW 200A 3P (A) (B) INV B2 125 kW 200A 3P (A) DYNAPOWER MPS125kW INVERTER, 125kW, 150.0Aac MAX OUTPUT CURRENT, 480Vac OUTPUT (C) 250kVA 480V Δ 277/480V Y 1 (F1) AC PANELBOARD FOR COMBINING BATTERY AC OUTPUT, 600A BUS, 600A MAIN BREAKER, 3P/3W, NEMA 3R 480V, 600A BUS, 3P/3W BESS-PANEL 200A 3P G N 600A 3P 277/480V, 800A BUS, 3P/4W GRID FORMING PANEL 200A 3P TBD 3P BESS AUX LOADS (F1) (B) INV B1 125 kW 200A 3P (A) 200A 3P ASC-150 STORAGE CONTROLLER AGC-150 GENERATOR CONTROLLER 15A 3P NETWORK SWITCH 200kW, 250 kVA GRID FORMING GENERATOR, 277/480V OUTPUT, 3P/4W, 240A MAXIMUM OUTPUT CURRENT (D2) 1 373 kWhr 373 kWhr 373 kWhr 1 SINGLE LINE, GENERATOR 2 SINGLE LINE, BESS 3 SINGLE LINE, GENERATOR/ BESS ALT. solar design associates inc HARVARD, MA 01451-0242 tel: 978-456-6855 fax: 978-772-9715 www.solardesign.com LOVANGO CAY REVISION NOTES MARK DATE DESCRIPTION PROFESSIONAL STAMP THIS DRAWING IS FOR INFORMATION PURPOSES ONLY. CERTIFICATION OR VALIDATION IS TO BE DONE BY A PROFESSIONAL WITH EXPERTISE IN THE REQUIRED FIELD AND A LICENSE IN THE STATE THAT THE INSTALLATION WILL RESIDE. CERTFICIATION OR VALIDATION TO BE INCLUDED AS PART OF THE SUBMITTALS FOR PERMITTING OF THE OVERALL PROJECT. CZM SET Friday, November 22, 2024 CONTRACTOR NAME STREET CITY/ST/ZIP NOTES NAME STREET CITY/ST/ZIP NOTES SITE SUBMISSION DATASHEETS PV606 2024-0712 Lovango Cay.pln AS NOTED CW, CS TP SHEET SIZE: DRAWING NO. DRAWING TITLE FILE NAME CHECKED BY DRAWN BY DATE DRAFTED: DRAWING SCALE 11/22/2024 ARCH D ST. JOHN, U.S. VIRGIN ISLANDS 00830 LOVANGO CAY, 1 NOT FOR CONSTRUCTION LOVANGO CAY * Chubb provides error and omission insurance to Silfab Solar Inc. SIL - 420 BG S I L F A B S O L A R . C O M Silfab Elite Back-contact technology with an innovative conductive backsheet and integrated cell design delivers the highest performance, durability and beautiful aesthetics. Manufactured exclusively in the United States. N O T J U S T A N O T H E R S O L A R PA N E L . SIDE BACK VIEW 2" [60mm] 13.1" [332mm] 47.2" [1200mm] 13.1" [332mm] 40.5" [1029mm] Ø0.17" [Ø4.2mm] (x2) Grounding Hole 38.9" [989mm] 8" [200mm] 47.25" [1200mm] Cable Length Mounting Hole (x4) Drainage Hole (x8) 73.4" [1864mm] 1.4" [35mm] 1.4" [35mm] 1.4" [35mm] 0.06" [1.5mm] 0.5" [12mm] 0.6" [15mm] 0.3" [7mm] SILFAB SOLAR INC. 800 Cornwall Ave Bellingham WA 98225 USA T +1 360.569.4733 info@silfabsolar.com S I L F A B S O L A R . C O M 1770 Port Drive Burlington WA 98233 USA T +1 360.569.4733 240 Courtneypark Drive East Mississauga ON L5T 2Y3 Canada T +1 905.255.2501 F +1 905.696.0267 Silfab - SIL-420-BG-20230224 No reproduction of any kind is allowed without permission. Data and information is subject to modifications without notice. © Silfab Solar Inc., 2022. Silfab Solar® is a registered trademark of Silfab Solar Inc. MECHANICAL PROPERTIES / COMPONENTS METRIC IMPERIAL Module weight 20.8±0.2 45.8±0.4 lbs Dimensions (H x L x D) 1864 mm x 1029 mm x 35 mm 73.4 in x 40.5 in x 1.4 in Maximum surface load (wind/snow)* 5400 Pa rear load / 5400 Pa front load 112.8 lb/ft2 rear load / 112.8 lb/ft2 front load Hail impact resistance ø 25 mm at 83 km/h ø 1 in at 51.6 mph Cells 66 high-efficiency mono-PERC MWT c-Si cells 166 x 166 mm 66 high-efficiency mono-PERC MWT c-Si cells 6.53 x 6.53 in Glass 3.2 mm high transmittance, tempered, anti-reflective coating 0.126 in high transmittance, tempered, anti-reflective coating Cables and connectors (refer to installation manual) 1200 mm ø 5.7 mm, MC4 from Staubli 47.2 in, ø 0.22 (12AWG), MC4 from Staubli Backsheet Multilayer, integrated insulation film and electrically conductive backsheet, superior hydrolysis and UV resistance, fluorine- free PV backsheet Frame Anodized Aluminum (Black) Bypass diodes 3 diodes-30SQ045T (45V max DC blocking voltage, 30A max forward rectified current) Junction Box UL 3730 Certified, IEC 62790 Certified, IP67 rated SHIPPING SPECS Modules Per Pallet: 27 or 27 (California) Pallets Per Truck 31 or 30 (California) Modules Per Truck 837 or 810 (California) ELECTRICAL SPECIFICATIONS 420 Test Conditions STC NOCT Module Power (Pmax) Wp 420 313 Maximum power voltage (Vpmax) V 38.51 35.89 Maximum power current (Ipmax) A 10.91 8.73 Open circuit voltage (Voc) V 46.36 43.45 Short circuit current (Isc) A 11.4 9.18 Module efficiency % 21.9% 20.4% Maximum system voltage (VDC) V 1000 Series fuse rating A 20 Power Tolerance Wp 0 to +10 Measurement conditions: STC 1000 W/m2 • AM 1.5 • Temperature 25 °C • NOCT 800 W/m² • AM 1.5 • Measurement uncertainty ≤ 3% Sun simulator calibration reference modules from Fraunhofer Institute. Electrical characteristics may vary by ±5% and power by 0 to +10W. TEMPERATURE RATINGS Temperature Coefficient Isc +0.046 %/°C Temperature Coefficient Voc -0.279 %/°C Temperature Coefficient Pmax -0.377 %/°C NOCT (± 2°C) 43.5 °C Operating temperature -40/+85 °C WARRANTIES Module product workmanship warranty 25 years** Linear power performance guarantee 30 years ≥ 97.1% end 1st yr ≥ 91.6% end 12th yr ≥ 85.1% end 25th yr ≥ 82.6% end 30th yr CERTIFICATIONS Product UL 61215-1:2017 Ed.1***, UL 61215-2:2017 Ed.1***, UL 61730-1:2017 Ed.1, UL 61730-2:2017 Ed.1 , CSA C22.2#61730-1:2019 Ed.2, CSA C22.2#61730-2:2019 Ed.2, IEC 61215-1:2016 Ed.1***, IEC 61215-2:2016 Ed.1***, IEC 61730-1:2016 Ed.2, IEC 61730-2:2016 Ed.2, IEC 61701:2020 (Salt Mist Corrosion), IEC 62716:2013 (Ammonia Corrosion), CEC Listing, UL Fire Rating: Type 1 Factory ISO9001:2015 * Warning. Read the Safety and Installation Manual for mounting specifications and before handling, installing and operating modules. ** 12 year extendable to 25 years subject to registration and conditions outlined under “Warranty” at silfabsolar.com. PAN files generated from 3rd party performance data are available for download at: silfabsolar.com/downloads. *** Certification in progress. 1) upcoming Integrated intelligence for future-proof system design. Sunny Tripower X is the new innovative inverter solution for commercial PV systems. Providing three MPP trackers with SMA ShadeFix string optimization technology for optimal PV array design flexibility and maximum energy yields. SMA’s proven integrated rapid shutdown support and reliable DC AFCI arc-fault protection ensure enhanced system safety. And now with the new integrated System Manager, powered by SMA’s ennexOS cross-sector energy management platform, Sunny Tripower X becomes the centerpiece of the SMA Energy System Business for comprehensive commercial energy systems now and in the future. Integrated System Manager • Monitoring and control for up to 5 inverters (max. 150 kVA) • Remote access with Sunny Portal powered by ennexOS • SMA Dynamic Power Control Enhanced safety • Integrated SunSpec PLC signal for module-level shutdown • Advanced DC AFCI arc-fault protection • Optional DC type 2 and type 1+2 surge protection Maximum yields • Three MPP trackers for flexible array design • SMA ShadeFix string level optimization • Integrated I-V curve diagnostics 1) Smart monitoring, control and service • SMA Smart Connected proactive monitoring and service solution • SMA ennexOS cross-sector energy management platform • Centerpiece of the proven SMA Energy System Business Sunny Tripower X-US 20 / 25 / 30 STP 20-US-50 / STP 25-US-50 / STP 30-US-50 SMA America, LLC Toll Free +1 888 4 SMA USA www.SMA-America.com STPX-US-50-DS-en-20 SMA and Sunny Tripower are registered trademarks of SMA Solar Technology AG. Amphenol is a registered trademark of Amphenol Corporation. All products and services described, as well as technical data, are subject to change, including for reasons of country-specific requirements, at any time without notice. SMA assumes no liability for mistakes or printing errors. For the latest information, please visit www.SMA-Solar.com Solar inverters made in Germany by SMA Solar Technology AG. Technical data Sunny Tripower X 20-US Sunny Tripower X 25-US Sunny Tripower X 30-US Input (DC) Maximum PV array power 30000 Wp 37500 Wp 45000 Wp Maximum input voltage 1000 V MPP voltage range 350 V to 800 V 430 V to 800 V 515 V to 800 V Minimum input voltage / initial input voltage 150 V / 188 V Maximum operating input current / short-circuit current per MPP tracker 24 A / 37.5 A Number of independent MPP trackers / string inputs per MPP tracker 3 / 2 Output (AC) Nominal output power 20000 W 25000 W 30000 W Maximum apparent power 20000 VA 25000 VA 30000 VA Nominal AC voltage 480 V / 277 V AC voltage range 244 V to 305 V Rated grid frequency / range 60 Hz / 50 Hz to 66 Hz Maximum output current 24 A 30 A 36 A Power factor at rated power / adjustable displacement 1 / 0.8 overexcited to 0.8 underexcited Output phases / line connection 3 / 3-(N)-PE Harmonics (THD) < 3 % Efficiency CEC efficiency 97.5 % 98 % 98 % Protection and safety features Load rated DC disconnect ● Ground fault monitoring / grid monitoring ● / ● DC reverse polarity protection / AC short-circuit protection ● / ● All-pole sensitive residual-current monitoring unit ● Protection class / overvoltage category I / III DC AFCI arc-fault protection ● SunSpec PLC signal for rapid shutdown ● DC surge protection type 2 / DC surge arrester type 1+2 ○ / ○ General data Dimensions (W/H/D) 728 mm / 762 mm / 266 mm (28.7 in / 30 in / 10.5 in) Device Weight 35 kg / 77 lbs Operating temperature range -25°C to +60°C (‒13°F to +140°F) Noise emission (typical) 59 dB(A) Topology / cooling concept Transformerless / OptiCool (forced convection, variable speed fans) Enclosure protection rating Type 4X (as per UL 50E) Corrosivity classification according to IEC 61701 C5* Maximum permissible value for relative humidity (non-condensing) 100 % Features / functions / accessories Mounting type Vertical rack / wall mount to 15° from horizontal DC connection / AC connection Amphenol H4 Plus / spring-cage terminal LED indicators (status / fault / communication) ● Network interfaces: Ethernet / WLAN ● (2 ports) / ● Data protocols: SMA Modbus / SunSpec Modbus / Speedwire ● / ● / ● Multi-function relay / Extension module slot / Digital inputs ● / ● / ● (6 inputs) SMA ShadeFix string level optimization ● Integrated I-V curve diagnostics 1) ● Integrated Plant Control / Q on Demand 24/7 ● / ● SMA Smart Connected (proactive monitoring and service support) ● Standard warranty 10 years Optional warranty extensions (total warranty coverage cannot exceed 20 years) +5 years, +10 years Certificates and approvals Certificates and approvals UL 62109-1, UL 1699B Ed. 1, CAN/CSA 22.2 No. 62109-1:16 / 62109-2:16, PV Rapid Shutdown System Equipment in accordance with UL1741:2021 FCC compliance FCC Part 15 Class A Grid interconnection standards UL 1741 SB, IEEE 1547:2018, compliance to SRDs: CA Rule 21, HECO Rule 14H, ISO-NE Integrated System Manager Maximum number of supported inverters / energy meters 5 / 1 Maximum system power PV inverters (nominal AC power) 150 kVA Centralized commissioning of all devices in the system ● Remote parameterization of SMA devices ● (via Sunny Portal powered by ennexOS) SMA Dynamic Power Control (e.g. zero export / Volt-VAr) 2) ○ Type designation STP 20-US-50 STP 25-US-50 STP 30-US-50 ● Standard features ○ Optional — Not available Data in nominal conditions Last revision: 08/2023 *≥ 500 m from the coast 1) Upcoming 2) Currently free software Accessories DC terminal cover DC-TERM-COVER DC Surge Protection Kits T2: DC_SPD_KIT6-10 T1+2: DC_SPD_KIT7_T1T2 SMA Sensor Module MD.SEN-US-40 SMA Data Manager M EDMM-US-10 MPS-125 Energy Storage Inverter The world’s most capable microgrid inverter Featuring a highly efficient three-level topology, the MPS-125 is easily integrated into customer supplied battery storage systems or can be supplied as part of Dynapower’s fully-integrated MPS-i energy storage system. Multiple MPS-125 energy storage inverters can be paralleled together to scale to meet the needs of any behind- the-meter energy storage installation. With all the functional capabilities of the grid-scale CPS inverter family, the MPS-125 supports frequency, voltage, and VAR support applications. With our patented Dynamic Transfer™ feature, the MPS-125 inverter monitors grid stability and will automatically disconnect and transition to stand-alone mode if a grid disturbance is detected, ensuring consistent power to critical loads. This parallelable 125kW energy storage inverter is transformer-less, air-cooled, and compact, and optimized for behind- the-meter energy storage applications. Key Technologies – Islanded Operation (UF Mode) – Dynamic Transfer – Black Start – Frequency Compensation Mode (F-Comp) – Volt-Var Compensation Mode (E-Comp) TM MPS-125 Energy Storage Inverter TECHNICAL SPECIFICATIONS Electrical AC Input Voltage: 480VAC 3 Phase Grid Frequency: 60 Hz Rated Output Apparent Power: 125kVA Rated Output Real Power: 125kW Rated Output Current: 150ARMS Overload AC Current: 180ARMS DC Voltage Range: 740-1500VDC Max DC Current: 171ADC Power Factor: 0 – 1.00 Leading or Lagging Current Harmonics: IEEE 1547 Compliant, <5% TDD Maximum Efficiency: 98.7% CEC Efficiency: 97% Environmental & Mechanical Operating Temp: -25 to +50°C, De-rated from +45 to +50°C Cooling: Forced Air Cooled Enclosure: UL 3R/IP 54 Max Elevation: 1000 Meters Full Power Up to 3000 Meters with Derating Dimensions (H x W x D): 42.5″ x 29.5″ x 15.5″ Weight: 230 lbs Certifications & Standards Compliance UL 1741 SA IEEE 1547 IEEE 519 CSA 22.2 #107.1 NFPA 70 Hardware Protections AC Breaker with Shunt Trip AC Surge Protection DC Disconnect DC Input Fuses DC Pre-charge (Optional) Software Protections Battery Voltage and Current Curtail Limits to protect battery AC Current Limiting Pending DC Over/Under Voltage, Over Current faults AC Over/Under Voltage, Over/Under Frequency, Over Current faults Anti-islanding Protection (Open Phase at inverter terminals) Temperature Monitoring and protective power curtailment Watchdog Timer to detect loss of communications 09-2023 US 85 Meadowland Drive, South Burlington, Vermont USA 05403 1.802.860.7200 | sales@dynapower.com dynapower.com