OWNER ARCHITECT Government of the United States, Virgin Islands HONORABLE ALBERT BRYAN, JR. GOVERNOR HONORABLE TREGENZA A. ROACH, ESQ LIEUTENANT GOVERNOR Government House St. Thomas 5047 (21-22) Kongens Gade, St. Thomas, VI 00802-6487 PHONE: (340) 774-0001 EMAIL: albert.bryan@go.vi.gov Office of Disaster Recovery Adrienne L. Williams-Octalien DIRECTOR V.I Public Finance Authority Office of Disaster Recovery 14A & 14C Strand Street Frederiksted, VI 00840 PHONE: (340) 202-1221 EMAIL: adrienne.williams@vi.gov Springline Architects, LLC Jerry Traino, AIA PRINCIPAL Gilbert Laban, RA PRINCIPAL 9713 Estate Thomas Building 1, Suite 200 St. Thomas, USVI 00802 PHONE: (321) 636-0274 EMAIL: gilbert@springlinearchitects.com jerry.traino@novusarchitects.com MEP/FP ENGINEER STRUCTURAL ENGINEER CIVIL ENGINEER Harris Civil Engineers, LLC Neil Wolfe, PE PROJECT MANAGER 1200 Hillcrest Street, Suite 200 Orlando, FL 32803 PHONE: (407) 629-4777 EMAIL: NeilW@harriscivilengineers.com SURVEYOR TLC Engineering Solutions Jim C. Mullen, PE, LEED AP PRINCIPAL Stephen Cotton, PE 7370 Cabot Court, Suite 103 Melbourne, FL 32940 PHONE: (321) 877-4260 EMAIL: jim.mullen@tlc-eng.com TLC Engineering Solutions Joel Figueroa-Vallines, PE SENIOR ASSOCIATE 7370 Cabot Court, Suite 103 Melbourne, FL 32940 PHONE: (321) 877-4231 EMAIL: joel.figueroa@tlc-eng.com The Green Piece Engineering + Environment Jeffrey Bateman, PE, PLS PRINCIPAL 5001 Chandlers Wharf, Suite 12 Christiansted, St. Croix, VI 00820 PHONE: (340) 778-7474 EMAIL: jeff@thegreenpiece.us Department of Public Works Derek Gabriel COMMISSIONER Jermaine McCleane, RA DISTRICT ENGINEERING 8244 Subbase St. Thomas, VI 00802 PHONE: (340) 776-4844 EMAIL: jermaine.mccleane@dpw.vi.gov Department of Health Justa E. Encarnacion COMMISSIONER Reuben Molloy ASSISTANT COMMISSIONER 4006 Estate Diamond Christiansted, St. Croix, VI 00820 PHONE: (340) 774-0001 EMAIL: reuben.molloy@doh.vi.gov Department of Human Services Averil George COMMISSIONER Sean Georges DEPUTY COMMISSIONER 3012 Golden Rock Christiansted, St. Croix, VI 00820 PHONE: (340) 774-0930 EMAIL: sean.georges@dhs.vi.gov Jacobs Christopher Cangello SENIOR PROJECT MANAGER S Warren Street Syracuse, NY PHONE: (315) 209-9713 EMAIL: christopher.cangello@jacobs.com ATLANTIC OCEAN CARIBBEAN SEA THE ISLAND OF ST. THOMAS PROJECT LOCATION REVISIONS: DRAWN BY: CHECKED BY: DATE: NOVUS JOB NUMBER SHEET NUMBER A B C D E ALL INFORMATION CONTAINED HEREIN IS THE PROPERTY OF SPRINGLINE ARCHITECTS L.L.C. THE CONCEPTS, IDEAS, DESIGNS AND DETAILS AS SHOWN ON THE DOCUMENTS WERE CREATED, DEVELOPED, AND PRESENTED FOR USE ON THIS SPECIFIC PROJECT AND SHALL NOT BE REUSED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN CONSENT OF SPRINGLINE ARCHITECTS L.L.C. THE OWNER SHALL BE PERMITTED TO RETAIN COPIES FOR INFORMATION AND REFERENCE PURPOSES ONLY. 1 2 3 4 5 1 2 3 4 5 NOT FOR CONSTRUCTION INPROGRESS DOCUMENTS FOR INTERIM REVIEW ONLY. NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION. SUBMISSIONS: Ref Description Date A Programming B 60% CDs C 90% CDs D 100% CDs E 30% CDs PROJECT TEAM PROJECT MAP AGENCIES ODR TASK ORDER NUMBER SHEET INDEX ODR TASK ORDER #: G0 10/15/2025 KB HK 1303 Hospital Ground St. Thomas, US. Virgin Islands 00802 KNUD HANSEN COMPLEX COVER SHEET PROGRAMMING PHASE 470-23-49, -50 PROGRAMMING PHASE 1303 Hospital Ground St. Thomas, US. Virgin Islands 00802 KNUD HANSEN COMPLEX 010-9-101981 & 010-8-101472 010-9-101981 & 010-8-101472 10/15/2025 CR # SHEET # SHEET NAME GENERAL G0 COVER SHEET G1 PRELIMINARY CODE ANALYSIS G2 PRELIMINARY LIFE SAFETY STUDY CIVIL C0.90 DEMOLITION AND EROSION CONTROL PLAN C1.00 SITE PLAN C2.00 GRADING PLAN C2.50 DRAINAGE PLAN C3.00 UTILITY PLAN ARCHITECTURAL A1 SITE PLAN A2 LOWER FLOOR SPACE PLAN A3 MAIN FLOOR SPACE PLAN A4 SECOND FLOOR SPACE PLAN A5 THIRD FLOOR SPACE PLAN A6 BUILDING SHELL PLANS A7 BUILDING ELEVATIONS A8 BUILDING ELEVATIONS A9 BUILDING SECTIONS A10 BUILDING SECTIONS A11 3D AXONS SITE No. Description Date 2024 INTERNATIONAL CODE COUNCIL BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS Name of Project: Address: Owner or Authorized Agent: Local Government Code Enforcement Jurisdiction: Architectural: Civil: Electrical: Fire Alarm: Plumbing: Mechanical: Sprinkler-Standpipe: Structural: Retaining Walls >5' High: Other: 2021 IBC Building Code: PRIMARY OCCUPANCY (Section 302): + Owned By: Private Owner STX STT FIRM DESIGN TEAM CONTACT NAME USE & OCCUPANCY Business Educational Factory: F-2 Low F-1 Moderate H-5 HPM H-4 Health H-3 Combust H-2 Deflagrate H-1 Detonate Hazardous: I-4 I-3 I-2 I-1 Institutional: 4 3 2 1 Condition: Mercantile 5 R-4 R-3 R-2 R-1 Residential: S-2 Low S-1 Moderate Storage: Utility and Miscellaneous Accessory Occupancy (Section 508.2) Incidental Uses (Table 509) MIXED USE & OCCUPANCY (SECTION 508) No (Single Use) Non-Separated Occupancies (508.3), Most Restrictive Occupancy (508.3.1): ______ Separated Occupancies (508.4), Required Separation (Table 508.4) : ________ [A] Actual Area of Occupancy 1 [A] Actual Area of Occupancy 2 [D] Allowable Area of Occupancy 1 [D] Allowable Area of Occupancy 2 1 FIRE PROTECTION REQUIREMENTS ACCESSIBLE PARKING (SECTION 1106) Bldg Height in Feet: ____________ Allowable Height (Table 504.3): __________ Bldg Height in Stories: __________ Allowable Stories (Table 504.4): _________ FIRE SEPARATION DISTANCE (FSD) BUILDING ELEMENT (TABLE 601) RATED JOINTS RATED ASSEMBLY DETAIL # ON SHEET # RATED PENETR- ATION RATING (Chapt. 7) PROV'D Structural frame, including columns, girders, trusses Bearing walls Exterior North East West South Interior bearing walls Nonbearing walls & partitions Exterior North East West South Interior walls & partitions Floor construction, including supporting beams and joists Shaft Enclosures - Exit Shaft Enclosures - Other Corridor Separation Occupancy/Fire Barrier Separation Party/ Fire Wall Separation Incidental Use Separation Tenant/Dwelling unit/ Sleeping unit Separation *Indicate section number permitting reduction LOT / PARKING AREA TOTAL # OF PARKING SPACES ACCESSIBLE SPACES REQUIRED REQUIRED PROVIDED 132'' Access Aisle 8' Access Aisle ACCESSIBLE PROVIDED TOTAL # Zip Code: Phone #: E-Mail: TELEPHONE E-MAIL New Construction Repair Date Constructed: Date Last Renovated: Current Occupancy: BASIC BUILDING DATA Construction Type: Sprinklers: Standpipes: Primary Fire District: I-A II-A III-A IV-B IV-C I-B II-B III-B Partial NFPA 13 No NFPA 13R NFPA 13D No Class: I II III Dry Wet No Yes IV-HT Flood Hazard Area: Yes No Special Uses (Section 401) Assembly: A-5 A-3 A-1 A-2 A-4 + + + = REQ'D* Smoke Barrier Separation Addition Chapter 14 1st Time Interior Upfit 2021 IEBC Existing Building Code: Prescriptive Proposed Occupancy: Roof construction, including supporting beams and joists (Other should include Truss, Precast, Pre-Engineered, Interior, etc.) Shell/Core - contact local AHJ for additional procedures/requirements Alteration Level I Alteration Level II Alteration Level III N/A Historic Property Change of Use Occupancy Category (Table 1604.5) Current: Proposed: Federal Government 1 Occup. ALLOWABLE AREA (TABLE 506.2) STORY TOTAL AREA (ACTUAL) FRONTAGE INCREASE (Section 506.3) 1 TOTAL ALLOWABLE AREA PER STORY (A1 + (A1 x If)) 2, 3, 4 1. Frontage area increases in accordance with Section 506.3 are computed thus: 2. Unlimited area applicable under conditions of Section 507. 3. Or as calculated by Equation 5-1, 5-2 or 5-3 (Section 506.2) to reach same result. 4. Maximum area of open parking garages - Table 406.5.4. Maximum area of air traffic control towers - 412.3.1. Floor ceiling assembly Columns supporting floors Roof ceiling assembly Columns supporting roofs Smoke Partition PERCENTAGE OF WALL OPENING CALCULATIONS (TABLE 705.8) ALLOWABLE AREA PER STORY (%) ACTUAL SHOWN ON PLANS (%) FSD FROM PROPERTY LINES (FEET) DEGREE OF OPENINGS PROTECTION REQ'D TOTAL ACCESSIBLE UNITS PROVIDED TOTAL UNITS ACCESSIBLE UNITS ACCESSIBLE DWELLING UNITS (SECTION 1108) PROVIDED TYPE A UNITS REQ'D TYPE B UNITS PROVIDED REQ'D PROVIDED TOTAL VAN SPACES 5' Access Aisle Relocation IV-A V-A V-B Day care Airport traffic control Ambulatory Care Higher Educ. laboratory Storm shelter HazMat Fuel-dispensing Business Educational Factory: F-2 Low F-1 Moderate H-5 HPM H-4 Health H-3 Combust H-2 Deflagrate H-1 Detonate Hazardous: I-4 I-3 I-2 I-1 Institutional: 4 3 2 1 Condition: Mercantile 5 R-4 R-3 R-2 R-1 Residential: S-2 Low S-1 Moderate Storage: Utility and Miscellaneous Assembly: A-5 A-3 A-1 A-2 A-4 Day care Airport traffic control Ambulatory Care Higher Educ. laboratory Storm shelter HazMat Fuel-dispensing 403 402 410 409 405 404 412 411 406 413 420 408 407 415 414 422 421 424 423 426 425 427 428 417 416 419 418 Furnace room where any piece of equipment is over 400,000 Btu per hour input Rooms with boilers where the largest piece of equipment is over 15 psi and 10 horsepower Refrigerant machinery room Hydrogen fuel gas rooms, not classified as Group H Incinerator rooms Paint shops, not classified as Group H, located in occupancies other than Group F In Group E occupancies, laboratories and vocational shops not classified as Group H In Group I-2 occupancies, laboratories not classified as Group H In ambulatory care facilities, laboratories not classified as Group H Laundry rooms over 100 square feet In Group I-2, laundry rooms over 100 square feet Group I-3 cells and Group I-2 patient rooms equipped with padded surfaces In Group I-2, physical plant maintenance shops In ambulatory care facilities or Group I-2 occupancies, waste and linen collection rooms with containers that have an aggregate volume of 10 cubic feet or greater Waste and linen collection rooms over 100 square feet (not ambulatory care or Group I-2) In ambulatory care facilities or Group I-2 occupancies, storage rooms greater than 100 square feet Electrical installations and transformers Other *505.2: Mezzanines per 505.2 shall not contribute to building area or stories. Mezzanines shall be included in fire area calculations. **506.1.3: If the basement does not exceed the area permitted for a one-story above grade building, it shall not contribute to total building area. BUILDING AREA (SECTION 506) SIDE REAR SIDE UL DESIGN # Area Calculations (508.4.2): + Special Provisions (Section 510) 510.3 510.2 510.9 510.5 510.4 510.6 510.8 510.7 FIRE SEPARATION DISTANCE OF PROJECTIONS (TABLE 705.2) ALLOWABLE DISTANCE ACTUAL DISTANCE FIRE SEPARATION DISTANCE (FEET) MINIMUM DISTANCE FROM LINE USED TO DETERMINE FSD SIDE REAR SIDE MIN. REQ'D NUMBER OF EXITS (TABLE 1006.3.3) 1 BUILDING STORY OR SPACE DESIGNATION TRAVEL DISTANCE (TABLE 1017.2) 1,2 ARRANGEMENT OF MEANS OF EGRESS (SECTION 1007) 1. For buildings with single exit (Table 1006.3.4) or spaces with one means of egress (Table 1006.2.1) 2. For assembly spaces (Section 1030) EXIT ARRANGEMENT BY DISTANCE MAX. ALLOWABLE ACTUAL PROVIDED ACTUAL PROVIDED ACTUAL PROVIDED REQ'D DISTANCE BETWEEN EXITS EGRESS WIDTH BY OCCUPANT LOAD a. Perimeter which fronts a public way or open space having 20 feet minimum width = ______ft (F) b. Total Building Perimeter = ______ft (P) c. Ratio (F/P) = ______(F/P) x 100% = Percentage of Building Perimeter _____ % Factor SQ FT by Type (A1) If 5 W (ft) Area Increase (A1 x If ) 5. Frontage increase factor is defined by Table 506.3.3. Area using means of egress (SQFT) 1 USE GROUP OR SPACE DESIGNATION REQ'D WIDTH (a x b) 2, 3 EGRESS WIDTH (Inches) (a) Calculated Occ. Load (b) Egress Width Factor (1005.3) Load Factor (Table 1004.5) 1 ACTUAL WIDTH (Cumulative) STAIR OTHER STAIR STAIR OTHER OTHER 1. See Table 1004.5 to determine use of NET area or GROSS area. 2. Only use calculated width if it exceeds: a. Minimum stair width (Section 1011.2) b. Minimum corridor width (Table 1020.3) c. Minimum door width (Section 1010.1.1) d. Minimum width of exit passageway (Section 1024.2) 3. For Assembly occupancies, see Section 1030. Regular EV (1107) REGULAR Interior exit stairways, ramps, and exit passageways a, b SPRINKLERED l GROUP NONSPRINKLERED a. Class C interior finish materials shall be permitted for wainscotting or paneling of not more than 1,000 square feet of applied surface area in the grade lobby where applied directly to a noncombustible base or over furring strips applied to a noncombustible base and fireblocked as required by Section 803.15.1. b. In other than Group I-3 occupancies in buildings less than three stories above grade plane, Class B interior finish for nonsprinklered buildings and Class C interior finish for sprinklered buildings shall be permitted in interior exit stairways and ramps. c. Requirements for rooms and enclosed spaces shall be based on spaces enclosed by partitions. Where a fire-resistance rating is required for structural elements, the enclosing partitions shall extend from the floor to the ceiling. Partitions that do not comply with this shall be considered to be enclosing spaces and the rooms or spaces on both sides shall be considered to be one room or space. In determining the applicable requirements for rooms and enclosed spaces, the specific occupancy thereof shall be the governing factor regardless of the group classification of the building or structure. d. Lobby areas in Group A-1, A-2 and A-3 occupancies shall be not less than Class B materials. e. Class C interior finish materials shall be permitted in places of assembly with an occupant load of 300 persons or less. f. For places of religious worship, wood used for ornamental purposes, trusses, paneling or chancel furnishing shall be permitted. g. Class B material is required where the building exceeds two stories. h. Class C interior finish materials shall be permitted in administrative spaces. i. Class C interior finish materials shall be permitted in rooms with a capacity of four persons or less. j. Class B materials shall be permitted as wainscotting extending not more than 48 inches above the finished floor in corridors and exit access stairways and ramps. k. Finish materials as provided for in other sections of Chapter 8. l. Applies when protected by an automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2. m. Corridors in ambulatory care facilities shall be provided with Class A or B materials. INTERIOR FINISH REQUIRMENTS BY OCCUPANCY (TABLE 803.13) k Rooms and enclosed spaces c Corridors and enclosure for exit access stairways and ramps Interior exit stairways, ramps, and exit passageways a, b Rooms and enclosed spaces c Corridors and enclosure for exit access stairways and ramps A-1, A-2 A-3 f, A-4, A-5 B, E, M, R-1 R-4 F H I-1 I-2 I-3 I-4 R-2 R-3 S U NO RESTRICTIONS NO RESTRICTIONS B B B B B B B B B B h, i B B h, i B B B C A C C C C C C C C C C C C B B B B A j C C C C C C C C m C C C C g C C A A A A A A A A B B B B C C C B B B B A C B B A d A d A A A A B KNUD HANSEN BUILDING & EQUIPMENT REPLACEMENT 1303 HOSPITAL GROUND RD, ST. THOMAS 00802 DEPARTMENT OF HUMAN SERVICES, DEPUTY COMM. SEAN GEORGES SEAN.GEORGES@DHS.VI.GOV 340.774.0930 X X X X X X X X X X X X 69,000 B SM Springline Architects, LLC Harris Civil Engineers, LLC TLC Engineering Solutions TLC Engineering Solutions TLC Engineering Solutions TLC Engineering Solutions TLC Engineering Solutions 0c 0 0 0 0 0 0 0 0 0 0 0 0 0 0 X X 0 0 TLC Engineering Solutions X B TLC Engineering Solutions 4 64'-9" 75' 4 II 1 10'-1" 10'-1" UP, S 45% 20' 21'-9" UP, S UP, S 40" 20' 21'-9" 40" 40" N/A 192 286 5 MIN 2 MIN 10 10 See Life Safety Plan 69,000 L M 2 3 69,000 B SM 69,000 69,000 B SM 69,000 69,000 B SM 69,000 41,230 39,580 22,300 22,300 TBD LOWER LEVEL 73 BUSINESS OCCUPANTS 37 MALE 1 WC; 1 UR; 1 LAV 37 FEMALE 3 WC, 1 LAV 1 TOTAL DRINKING FOUNTAIN MAIN LEVEL 100 BUSINESS OCCUPANTS 128 ASSEMBLY OCCUPANTS 50 MALE 1 WC; 1 UR; 1 LAV 64 MALE 1 WC, 1 UR, 1 LAV 50 FEMALE 3 WC, 1 LAV 64 FEMALE 3 WC, 1 LAV 1 TOTAL DRINKING FOUNTAIN SECOND LEVEL 149 BUSINESS OCCUPANTS 75 MALE 2 WC; 1 UR; 1 LAV 75 FEMALE 4 WC, 2 LAV 1 TOTAL DRINKING FOUNTAIN THIRD LEVEL 140 BUSINESS OCCUPANTS 87 ASSEMBLY OCCUPANTS 70 MALE 2 WC; 1 UR; 1 LAV 44 MALE 1 WC, 1 UR, 1 LAV 70 FEMALE 4 WC, 2 LAV 44 FEMALE 2 WC, 1 LAV 2 TOTAL DRINKING FOUNTAINS 2024 UPC TABLE 422.1 LOWER MAIN SECOND THIRD 227 149 228 73 10,830 16,890 22,300 22,300 VARIES; SEE LIFE SAFETY PLAN 0.3 0.2 0.3 0.2 0.3 0.2 0.3 0.2 45.4 68.1 68.4 45.6 TBD TBD TBD TBD TBD TBD TBD TBD 29.8 44.7 21.9 14.6 LOWER MAIN SECOND THIRD 2 2 2 2 3 3 5 5 X NL NL TBD TBD TBD TBD TBD TBD TBD TBD 1 N/A N/A N/A N/A N/A N/A X TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD N/A N/A N/A N/A N/A N/A TBD TBD TBD X X PROVIDED REQUIRED WATER CLOSET URINALS LAVATORIES DRINKING FOUNTAIN MALE FEMALE MALE FEMALE MOP SINK 8 16 6 6 8 5 6 TBD TBD TBD TBD TBD TBD TBD 2010 DEPARTMENT OF JUSTICE ADA STANDARDS FOR ACCESSIBLE DESIGN 2019 UNITED STATES VIRGIN ISLANDS ZONING, BUILDING AND HOUSING LAWS & REGULATIONS 2024 INTERNATIONAL FUEL GAS CODE (IFGC) Complete demolition and rebuild of administrative offices for the Department of Human Services. New building to be 4-stories. Building will include Department of Health Community Health clinic space on second level. Project includes new parking and landscaping. GENERAL BUILDING INFO AND ZONING REQUIREMENTS ACTUAL PROJECT DESCRIPTION ZONING DISTRICT (T.29 § 223) REQUIRED LOT AREA MAX LOT OCCUPANCY MAXIMUM HEIGHT LIMIT GENERAL PROJECT INFORMATION & VIRGIN ISLANDS ZONING, BUILDING AND HOUSING LAWS & REGULATIONS APPLICABLE CODES & REGULATIONS V.I. DEPARTMENT OF PLANNING & NATURAL RESOURCES HISTORIC PRESERVATION GUIDELINES 2024 INTERNATIONAL BUILDING CODE (IBC) 2024 INTERNATIONAL RESIDENTIAL CODE (IRC) 2024 INTERNATIONAL EXISTING BUILDING CODE (IEBC) 2024 INTERNATIONAL FIRE CODE (IFC) 2024 UNIFORM PLUMBING CODE (UPC) 2024 INTERNATIONAL MECHANICAL CODE (IMC) 2024 INTERNATIONAL ZONING CODE (IZC) 2024 INTERNATIONAL SWIMMING POOL AND SPA CODE (ISPSC) SECRETARY OF THE INTERIOR'S STANDARDS FOR THE TREATMENT OF HISTORIC PROPERTIES OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION LAWS & REGULATIONS PART 1926 OTHER: ___________________________________________________________ OTHER: ___________________________________________________________ ADDRESS ISLAND MINIMUM LOT WIDTH CONSERVATION EARTH CHANGE PERMIT (T.12 § 533) COASTAL ZONE MANAGEMENT PERMIT (T.12 § 539) HISTORIC DISTRICT (T.29 § 111) PERMITTED USE (T.29 § 228) ACCESSORY USE (T.29 § 233) MIN. FRONT YARD MIN. SIDE YARD MIN. REAR YARD PERMITTED DENSITY PERSONS PER ACRE LIMIT USABLE OPEN SPACE FLOOR AREA RATIO SECONDARY KITCHEN RESTRICTION VARIANCE REQUIRED ESTATE YES NO ACTUAL ACTUAL ACTUAL ACTUAL ACTUAL REQUIRED SETBACKS MIN. SIDE YARD ACTUAL NO BUILDING SHALL EXCEED THE MAXIMUM HEIGHT ALLOWED IN THE ADJOINING ZONING DISTRICT ACTUAL ACTUAL ACTUAL ACTUAL ACTUAL FLOOD INSURANCE RISK MAP # FLOOD HAZARD ZONE CONDITIONAL USE (T.29 § 231) YES: NO LIFE SAFETY SYSTEM REQUIREMENTS Yes Exit Signs: Emergency Lighting: No No Yes ENERGY SUMMARY (2021 IECC) THERMAL ENVELOPE PER TABLE C402.1.4: (Prescriptive method only) Energy Code - Prescriptive Energy Code - Performance Roof/Attic Requirement: _______ U-Value of total assembly: R-Value of insulation: Skylights in each assembly: U-Value of skylight: Exterior Wall Requirement: ________ Description of assembly: U-Value of total assembly: R-Value of insulation: Openings (windows or doors with glazing) U-Value of assembly: Solar heat gain coefficient: Walls, below grade, Requirement: _______ Description of assembly: U-Value of total assembly: R-Value of insulation: Floors, over unconditioned space, Requirement: _______ Floors, slab on grade, Requirement: _______ Description of assembly: LIFE SAFETY PLAN REQUIREMENTS Fire and/or smoke rated wall locations (Chapter 7) Assumed and real property line locations (if not on site plan) Exterior wall opening area with respect to distance to assumed property lines (705.8) Occupancy Use for each area as it relates to occupant load calculation (Table 1004.5) Occupant loads for each area Exit access travel distances (1017) Common path of travel distances (Tables 1006.2.1 & 1006.3.2(1)) Dead end lengths (1020.5) Clear exit widths for each exit door Maximum calculated occupant load capacity each exit door can accommodate based on egress width (1005.3) Actual occupant load for each exit door A separate schematic plan indicating where fire rated floor/ ceiling and/or roof structure is provided for purposes of occupancy separation Location of doors with panic hardware (1010.2.9) Location of doors with delayed egress locks and the amount of delay (1010.2.13) Location of doors with electromagnetic egress locks (1010.2.11) Location of doors equipped with hold-open devices (1010.2.12) Location of emergency escape windows (1031) The square footage of each fire area (202) The square footage of each smoke compartment for Occupancy Classification I-2 (407.5) * Note on sheet any code exceptions or table notes that may have been utilized regarding the items above EXISTING BUILDING ENVELOPE COMPLIES WITH CODE: EXEMPT BUILDING: *Provide code or statutory reference: No Yes, the remainder of this section is not applicable. CLIMATE ZONE (Table C301.1): METHOD OF COMPLIANCE: ASHRAE 90.1 - Prescriptive ASHRAE 90.1 - Performance Other - Performance: (source) Projection factor: Door R-Value: Description of assembly: U-Value of total assembly: R-Value of insulation: U-Value of total assembly: R-Value of insulation: Horizontal/Vertical Requirement: Slab heated: Yes No Existing structures within 30' of the building No Yes, the remainder of this section is not applicable.* Fire Alarm: No Yes Smoke Detection Systems: No Yes Panic Hardware: No Yes Partial Life Safety Plan Sheet(s) # OFF-STREET PARKING REQUIREMENT EXTERIOR WALL ASSEMBLY ROOF ASSEMBLY ROOF AREA 1ST FLOOR 2ND FLOOR TOTAL AREA CISTERN CAPACITY (T.29 § 308) 4 spaces OFF-STREET LOADING REQUIREMENT PROXIMITY OF PARKING SCREENING AND LANDSCAPING MINIMUM DISTANCE AND SETBACK BUMPER GUARDS REQUIRED PARKING AREA SURFACING LIGHTING REQUIREMENTS PARKING & LOADING REQUIRED (T.29 § 230) WOOD-FRAMED METAL-FRAMED OFF-STREET PARKING PROVIDED OFF-STREET LOADING PROVIDED BASEMENT FLOOR AREA (SQ. FT.) STRUCTURE MASONRY/CONCRETE STRUCTURAL STEEL YES: NO x x x x x x x x x x x 1303 Hospital Ground, Knud Hansen Complex/Building A ST. THOMAS HOSPITAL GROUND P OFFICE, COMMUNITY CENTER, OUTPATIENT CLINIC x Virgin Islands: 1A Warm Humid - Tropical R-20ci U-0.70 R-5.7ci NR NR x NR N/A N/A N/A N/A 4 stories N/A N/A N/A N/A N/A N/A N/A 183 spaces X 7800000028G x N/A N/A N/A X X X Fence, wall or hedge not less than four (4) feet and with no solid portion more than six (6) feet in height to provide year-round screening. The space between such fence, wall or hedge shall be landscaped with grass, hardy shrubs or suitable ground cover and maintained in good condition. 10 feet from any building Yes Asphalt or concrete providing zero dust No light reflected to residential area [R-3 max 6 stories] 286 spaces X X 1 space - TBA during SD 111,150 GALLONS MINIMUM 24,700 TBD CONCRETE x x x x x SDA.G2 x x x x x x x U-0.5 U-0.151 U-0.37 TBD TBD TBD TBD U-0.151 U-0.039 U-0.039 x x x x x x x x x x REVISIONS: DRAWN BY: CHECKED BY: DATE: NOVUS JOB NUMBER SHEET NUMBER A B C D E ALL INFORMATION CONTAINED HEREIN IS THE PROPERTY OF SPRINGLINE ARCHITECTS L.L.C. THE CONCEPTS, IDEAS, DESIGNS AND DETAILS AS SHOWN ON THE DOCUMENTS WERE CREATED, DEVELOPED, AND PRESENTED FOR USE ON THIS SPECIFIC PROJECT AND SHALL NOT BE REUSED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN CONSENT OF SPRINGLINE ARCHITECTS L.L.C. THE OWNER SHALL BE PERMITTED TO RETAIN COPIES FOR INFORMATION AND REFERENCE PURPOSES ONLY. 1 2 3 4 5 1 2 3 4 5 NOT FOR CONSTRUCTION INPROGRESS DOCUMENTS FOR INTERIM REVIEW ONLY. NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION. SUBMISSIONS: Ref Description Date A Programming B 60% CDs C 90% CDs D 100% CDs E 30% CDs ODR TASK ORDER NUMBER G1 10/15/2025 KB HK 1303 Hospital Ground St. Thomas, US. Virgin Islands 00802 KNUD HANSEN COMPLEX PRELIMINARY CODE ANALYSIS PROGRAMMING PHASE 470-23-49, -50 010-9-101981 & 010-8-101472 10/15/2025 OCCUPANCY BY FLOOR: including parking areas LOWER 175 MAIN 310 SECOND 149 THIRD 227 BUILDING TOTAL 861 BUSINESS 667 PARKING S-2 194 No. Description Date DEPARTMENT OF HEALTH TBD TBD UP UP UP DN DN UP DN DN DN DN 810 SF PUMPS & EQUIPMENT 1200 SF FIRE & DOMESTIC CISTERNS MIN. DIST. BETWEEN EXITS @ 1/3 MAX. DIAGONAL = (+/-) 51'-10" ACTUAL DIST. BETWEEN EXITS = 108'-2" DIAGONAL OF AREA SERVED BY EGRESS COMPONENTS = 155'-6" 10,830 SF BUSINESS (B) USE 30,400 SF PARKING (S-2) USE BELOW GRADE BELOW GRADE PROPERTY LINE STAIR 2 STAIR 1 STAIR 3 STAIR 4 STAIR 5 PUBLIC RIGHT OF WAY FSD 6' - 9" TRAVEL DISTANCE 104' - 3" < 300' DEAD END 15' - 6" DEAD END 21' - 6" 73 OCCUPANTS 102 OCCUPANTS DEAD END 20' - 1" MIN. DIST. BETWEEN EXITS @ 1/3 MAX. DIAGONAL = (+/-) 37'-3" ACTUAL DIST. BETWEEN EXITS = 63'-8" DIAGONAL OF AREA SERVED BY EGRESS COMPONENTS = 160'-6" TRAVEL DISTANCE 116' - 3" < 300' MIN. DIST. BETWEEN EXITS @ 1/3 MAX. DIAGONAL = (+/-) 53'-6" ACTUAL DIST. BETWEEN EXITS = 128'-9" DIAGONAL OF AREA SERVED BY EGRESS COMPONENTS = 111'-7" DN TRAVEL DISTANCE 71' - 6" < 300' 14,980 SF BUSINESS (B) USE + 1,910 SF ASSEMBLY (A-3) ACCESSORY TO B USE 24,600 SF PARKING (S-2) USE STAIR 2 STAIR 1 STAIR 3 STAIR 4 STAIR 5 ACCESS ROAD 10' - 1" EXISTING BUILDING ON SAME LOT DEAD END 17' - 1" DEAD END 21' - 4" 100 OCCUPANTS 82 OCCUPANTS 128 OCCUPANTS MIN. DIST. BETWEEN EXITS @ 1/3 MAX. DIAGONAL = (+/-) 45'-6" ACTUAL DIST. BETWEEN EXITS = 88'-2" DIAGONAL OF AREA SERVED BY EGRESS COMPONENTS = 172'-0" DIAGONAL OF AREA SERVED BY EGRESS COMPONENTS = 137'-2" MIN. DIST. BETWEEN EXITS @ 1/3 MAX. DIAGONAL = (+/-) 54'-10" ACTUAL DIST. BETWEEN EXITS = 119'-9" 22,300 SF BUSINESS (B) USE STAIR 2 STAIR 1 STAIR 3 TRAVEL DISTANCE 113' - 4" < 300' TRAVEL DISTANCE 125' - 0" < 300' TRAVEL DISTANCE 123' - 11" < 300' DEAD END 24' - 8" DEAD END 23' - 3" DEAD END 28' - 11" 149 OCCUPANTS MIN. DIST. BETWEEN EXITS @ 1/3 MAX. DIAGONAL = (+/-) 45'-10" ACTUAL DIST. BETWEEN EXITS = 95'-2" MIN. DIST. BETWEEN EXITS @ 1/3 MAX. DIAGONAL = (+/-) 80'-0" ACTUAL DIST. BETWEEN EXITS = 114'-6" DIAGONAL OF AREA SERVED BY EGRESS COMPONENTS = 137'-6" DIAGONAL OF AREA SERVED BY EGRESS COMPONENTS = 162'-7' 21,000 SF BUSINESS (B) USE + 1,300 SF ASSEMBLY (A-3) ACCESSORY TO B USE STAIR 2 STAIR 1 STAIR 3 DEAD END 32' - 10" DEAD END 27' - 9" TRAVEL DISTANCE 112' - 11" < 300' TRAVEL DISTANCE 110' - 11" < 300' 140 OCCUPANTS 87 OCCUPANTS DIAGONAL OF AREA SERVED BY EGRESS COMPONENTS = 55' MIN. DIST. BETWEEN EXITS @ 1/3 MAX. DIAGONAL = (+/-) 18'-4" ACTUAL DIST. BETWEEN EXITS = 30'-5" DEAD END 21' - 3" DEAD END 25' - 2" SENIOR CITIZENS AFFAIRS STRIVE INTAKE & EMERGENCY SERVICES RESIDENTIAL SERVICES & INTERSTATE COMPACT AFFAIRS OPERATIONS VOCATIONAL REHAB DIVISION OF FAMILY ASSISTANCE (SNAP) OFFICE OF MEDICAID (MAP) UTILITY SPACE/ BUILDING SYSTEMS SHARED AMENITY INTERVENTION & PREVENTION SERVICES OFFICE OF HEAD START OFFICE OF CHILD CARE & REGULATORY SERVICES DIVISION OF CHILDREN & FAMILY SERVICES OFFICE OF THE COMMISSIONER FISCAL & ADMINISTRATIVE HUMAN RESOURCES & LABOR RELATIONS MANAGEMENT INFORMATION SYSTEMS COMMUNITY HEALTH COMMUNICABLE DISEASE DEPARTMENTAL LEGEND FEC - FIRE EXTINGUISHER CABINET, SEMI-RECESSED LIFE SAFETY LEGEND REFER TO ELECTRICAL FOR COMPLETE LIST EXIT SIGN OCCUPANCY COUNT OF AREA DOOR PROVIDED W/ PANIC HARDWARE OR PUSH/PULL P EXIT DOOR CAP LOAD XX" CLEAR CAP - EXIT CAPACITY LOAD - ANTICIPATED LOAD CLEAR - CLEAR EXIT DOOR WIDTH (INCHES) 10 DIAGONAL OF BUILDING OR AREA DISTANCE BETWEEN EXIT DOORS EGRESS TRAVEL PATH ASSEMBLY A-3 USE PARKING S-2 USE BUSINESS B USE 1" = 20'-0" G2 LOWER FLOOR LIFE SAFETY PLAN B1 1" = 20'-0" G2 MAIN FLOOR LIFE SAFETY PLAN B2 1" = 20'-0" G2 SECOND FLOOR LIFE SAFETY PLAN B3 1" = 20'-0" G2 THIRD FLOOR LIFE SAFETY PLAN B4 REVISIONS: DRAWN BY: CHECKED BY: DATE: NOVUS JOB NUMBER SHEET NUMBER A B C D E ALL INFORMATION CONTAINED HEREIN IS THE PROPERTY OF SPRINGLINE ARCHITECTS L.L.C. THE CONCEPTS, IDEAS, DESIGNS AND DETAILS AS SHOWN ON THE DOCUMENTS WERE CREATED, DEVELOPED, AND PRESENTED FOR USE ON THIS SPECIFIC PROJECT AND SHALL NOT BE REUSED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN CONSENT OF SPRINGLINE ARCHITECTS L.L.C. THE OWNER SHALL BE PERMITTED TO RETAIN COPIES FOR INFORMATION AND REFERENCE PURPOSES ONLY. 1 2 3 4 5 1 2 3 4 5 NOT FOR CONSTRUCTION INPROGRESS DOCUMENTS FOR INTERIM REVIEW ONLY. NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION. SUBMISSIONS: Ref Description Date A Programming B 60% CDs C 90% CDs D 100% CDs E 30% CDs ODR TASK ORDER NUMBER G2 10/15/2025 KB HK 1303 Hospital Ground St. Thomas, US. Virgin Islands 00802 KNUD HANSEN COMPLEX PRELIMINARY LIFE SAFETY STUDY PROGRAMMING PHASE 470-23-49, -50 010-9-101981 & 010-8-101472 10/15/2025 dead ends limited to 50' exit access travel distance limited to 300' common path limited to 100' OCCUPANCY BY FLOOR: LOWER 175 MAIN 310 SECOND 149 THIRD 227 BUILDING TOTAL 861 BUSINESS 667 PARKING S-2 194 No. Description Date REVISIONS: DRAWN BY: CHECKED BY: DATE: NOVUS JOB NUMBER SHEET NUMBER A B C D E ALL INFORMATION CONTAINED HEREIN IS THE PROPERTY OF SPRINGLINE ARCHITECTS L.L.C. THE CONCEPTS, IDEAS, DESIGNS AND DETAILS AS SHOWN ON THE DOCUMENTS WERE CREATED, DEVELOPED, AND PRESENTED FOR USE ON THIS SPECIFIC PROJECT AND SHALL NOT BE REUSED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN CONSENT OF SPRINGLINE ARCHITECTS L.L.C. THE OWNER SHALL BE PERMITTED TO RETAIN COPIES FOR INFORMATION AND REFERENCE PURPOSES ONLY. 1 2 3 4 5 1 2 3 4 5 NOT FOR CONSTRUCTION INPROGRESS DOCUMENTS FOR INTERIM REVIEW ONLY. NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION. SUBMISSIONS: Ref Description Date A Schematic B 60% CDs C 90% CDs D 100% CDs E 30% CDs ODR PROJECT NUMBER 10.17.2025 NW CB 1303 Hospital Ground St. Thomas, US. Virgin Islands 00802 KNUD HANSEN COMPLEX PROGRAMMING PHASE 470-23-49 101981 No. Description Date DEMOLITION AND EROSION CONTROL PLAN C0.90 DN DHS / DOH SHARED SURFACE PARKING 4 STORIES (75,800 SF) DOH PARKING DECK 22,578 SF THIRD 22,578 SF SECOND 20,054 SF MAIN 10,590 SF LOWER 75,800 SF TOTAL 2nd TIER (OPEN) (76 spaces) 1st TIER (OPEN) (82 spaces) (TOTAL = 137 spaces) SITE PLAN C1.00 REVISIONS: DRAWN BY: CHECKED BY: DATE: NOVUS JOB NUMBER SHEET NUMBER A B C D E ALL INFORMATION CONTAINED HEREIN IS THE PROPERTY OF SPRINGLINE ARCHITECTS L.L.C. THE CONCEPTS, IDEAS, DESIGNS AND DETAILS AS SHOWN ON THE DOCUMENTS WERE CREATED, DEVELOPED, AND PRESENTED FOR USE ON THIS SPECIFIC PROJECT AND SHALL NOT BE REUSED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN CONSENT OF SPRINGLINE ARCHITECTS L.L.C. THE OWNER SHALL BE PERMITTED TO RETAIN COPIES FOR INFORMATION AND REFERENCE PURPOSES ONLY. 1 2 3 4 5 1 2 3 4 5 NOT FOR CONSTRUCTION INPROGRESS DOCUMENTS FOR INTERIM REVIEW ONLY. NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION. SUBMISSIONS: Ref Description Date A Schematic B 60% CDs C 90% CDs D 100% CDs E 30% CDs ODR PROJECT NUMBER 10.17.2025 NW CB 1303 Hospital Ground St. Thomas, US. Virgin Islands 00802 KNUD HANSEN COMPLEX COVER SHEET PROGRAMMING PHASE 470-23-49 101981 No. Description Date SDA.G0 DN DHS / DOH SHARED SURFACE PARKING 4 STORIES (75,800 SF) DOH PARKING DECK 22,578 SF THIRD 22,578 SF SECOND 20,054 SF MAIN 10,590 SF LOWER 75,800 SF TOTAL 2nd TIER (OPEN) (76 spaces) 1st TIER (OPEN) (82 spaces) (TOTAL = 137 spaces) REVISIONS: DRAWN BY: CHECKED BY: DATE: NOVUS JOB NUMBER SHEET NUMBER A B C D E ALL INFORMATION CONTAINED HEREIN IS THE PROPERTY OF SPRINGLINE ARCHITECTS L.L.C. THE CONCEPTS, IDEAS, DESIGNS AND DETAILS AS SHOWN ON THE DOCUMENTS WERE CREATED, DEVELOPED, AND PRESENTED FOR USE ON THIS SPECIFIC PROJECT AND SHALL NOT BE REUSED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN CONSENT OF SPRINGLINE ARCHITECTS L.L.C. THE OWNER SHALL BE PERMITTED TO RETAIN COPIES FOR INFORMATION AND REFERENCE PURPOSES ONLY. 1 2 3 4 5 1 2 3 4 5 NOT FOR CONSTRUCTION INPROGRESS DOCUMENTS FOR INTERIM REVIEW ONLY. NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION. SUBMISSIONS: Ref Description Date A Schematic B 60% CDs C 90% CDs D 100% CDs E 30% CDs ODR PROJECT NUMBER 10.17.2025 NW CB 1303 Hospital Ground St. Thomas, US. Virgin Islands 00802 KNUD HANSEN COMPLEX PROGRAMMING PHASE 470-23-49 101981 No. Description Date GRADING PLAN C2.00 DN DHS / DOH SHARED SURFACE PARKING 4 STORIES (75,800 SF) DOH PARKING DECK 22,578 SF THIRD 22,578 SF SECOND 20,054 SF MAIN 10,590 SF LOWER 75,800 SF TOTAL 2nd TIER (OPEN) (76 spaces) 1st TIER (OPEN) (82 spaces) (TOTAL = 137 spaces) REVISIONS: DRAWN BY: CHECKED BY: DATE: NOVUS JOB NUMBER SHEET NUMBER A B C D E ALL INFORMATION CONTAINED HEREIN IS THE PROPERTY OF SPRINGLINE ARCHITECTS L.L.C. THE CONCEPTS, IDEAS, DESIGNS AND DETAILS AS SHOWN ON THE DOCUMENTS WERE CREATED, DEVELOPED, AND PRESENTED FOR USE ON THIS SPECIFIC PROJECT AND SHALL NOT BE REUSED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN CONSENT OF SPRINGLINE ARCHITECTS L.L.C. THE OWNER SHALL BE PERMITTED TO RETAIN COPIES FOR INFORMATION AND REFERENCE PURPOSES ONLY. 1 2 3 4 5 1 2 3 4 5 NOT FOR CONSTRUCTION INPROGRESS DOCUMENTS FOR INTERIM REVIEW ONLY. NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION. SUBMISSIONS: Ref Description Date A Schematic B 60% CDs C 90% CDs D 100% CDs E 30% CDs ODR PROJECT NUMBER 10.17.2025 NW CB 1303 Hospital Ground St. Thomas, US. Virgin Islands 00802 KNUD HANSEN COMPLEX PROGRAMMING PHASE 470-23-49 101981 No. Description Date DRAINAGE PLAN C2.50 DN DHS / DOH SHARED SURFACE PARKING 4 STORIES (75,800 SF) DOH PARKING DECK 22,578 SF THIRD 22,578 SF SECOND 20,054 SF MAIN 10,590 SF LOWER 75,800 SF TOTAL 2nd TIER (OPEN) (76 spaces) 1st TIER (OPEN) (82 spaces) (TOTAL = 137 spaces) REVISIONS: DRAWN BY: CHECKED BY: DATE: NOVUS JOB NUMBER SHEET NUMBER A B C D E ALL INFORMATION CONTAINED HEREIN IS THE PROPERTY OF SPRINGLINE ARCHITECTS L.L.C. THE CONCEPTS, IDEAS, DESIGNS AND DETAILS AS SHOWN ON THE DOCUMENTS WERE CREATED, DEVELOPED, AND PRESENTED FOR USE ON THIS SPECIFIC PROJECT AND SHALL NOT BE REUSED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN CONSENT OF SPRINGLINE ARCHITECTS L.L.C. THE OWNER SHALL BE PERMITTED TO RETAIN COPIES FOR INFORMATION AND REFERENCE PURPOSES ONLY. 1 2 3 4 5 1 2 3 4 5 NOT FOR CONSTRUCTION INPROGRESS DOCUMENTS FOR INTERIM REVIEW ONLY. NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION. SUBMISSIONS: Ref Description Date A Schematic B 60% CDs C 90% CDs D 100% CDs E 30% CDs ODR PROJECT NUMBER 10.17.2025 NW CB 1303 Hospital Ground St. Thomas, US. Virgin Islands 00802 KNUD HANSEN COMPLEX PROGRAMMING PHASE 470-23-49 101981 No. Description Date UTILITY PLAN C3.00 NORTH DOH + WIC(7) + B.H. (7) PARKING REQUIRED BY CODE 21+7+7+32 = 67 136 VEHICLE FLEET TOTAL SPACES PROVIDED EXCESS OR DEFECIT 42 50 203 DHS TOTAL NEED 109 186 295 92 290 5 HOSPITAL GROUND ROAD OLD HOSPITAL ROAD HOSPITAL GROUND ROAD C1 A9 A1 A9 DHS / DOH SHARED SURFACE PARKING 4 STORIES (73,556 SF) DOH WIC PARKING DECK CHILLERS DOH JSM GENERATOR 20 20 9 11 4 20 3 3 8 32 18 18 9 DUMPSTERS 4 HISTORIC BUILDING 2 HISTORIC BUILDING 1 34 2 77 SPACES MAIN LEVEL 75 SPACES LOWER LEVEL 24' GATE 24' GATE 24' GATE 24' GATE PATH TO NORTH ROAD NOT AN ACCESSIBLE ROUTE 22' GATE LOADING LOADING A7 C1 A8 C1 A8 A1 A7 A1 LOWER LEVEL GARAGE ENTRY MAIN ENTRY BETHLEHEM HOUSE ENTRY STEP STREET ACCESSIBLE PATH TO WIC B1 A10 A1 A10 REVISIONS: DRAWN BY: CHECKED BY: DATE: NOVUS JOB NUMBER SHEET NUMBER A B C D E ALL INFORMATION CONTAINED HEREIN IS THE PROPERTY OF SPRINGLINE ARCHITECTS L.L.C. THE CONCEPTS, IDEAS, DESIGNS AND DETAILS AS SHOWN ON THE DOCUMENTS WERE CREATED, DEVELOPED, AND PRESENTED FOR USE ON THIS SPECIFIC PROJECT AND SHALL NOT BE REUSED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN CONSENT OF SPRINGLINE ARCHITECTS L.L.C. THE OWNER SHALL BE PERMITTED TO RETAIN COPIES FOR INFORMATION AND REFERENCE PURPOSES ONLY. 1 2 3 4 5 1 2 3 4 5 NOT FOR CONSTRUCTION INPROGRESS DOCUMENTS FOR INTERIM REVIEW ONLY. NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION. SUBMISSIONS: Ref Description Date A Programming B 60% CDs C 90% CDs D 100% CDs E 30% CDs ODR TASK ORDER NUMBER A1 10/15/2025 KB HK 1303 Hospital Ground St. Thomas, US. Virgin Islands 00802 KNUD HANSEN COMPLEX SITE PLAN PROGRAMMING PHASE 470-23-49, -50 010-9-101981 & 010-8-101472 10/15/2025 1" = 20'-0" A1 CONCEPT A - SITE PLAN A1 No. Description Date C1 A9 A1 A9 DHS LOBBY 154 SF MECHANICAL 80 SF ELECTRICAL 72 SF IT 52 SF CUST. 61 SF F PUBLIC 61 SF M PUBLIC 100 SF CUST. SUPPLY 120 SF CUSTODIAL OFFICE 100 SF DIRECTOR 50 SF MAINT. STAFF 50 SF MAINT. STAFF 50 SF MAINT. STAFF 50 SF MAINT. STAFF 50 SF MAINT. STAFF 50 SF MAINT. STAFF 102 SF TOOLS 96 SF COOLER 100 SF FREEZER 47 SF COPY/ PRINT 100 SF SOCIAL WORKER 82 SF SUPPLIES 48 SF DETAINEE TOILET 80 SF HOLDING ROOM 82 SF RECORDS 100 SF SOCIAL WORKER 80 SF RECEPTION 121 SF DISTRICT MGR SOCIAL WORKER 100 SF SOCIAL WORKER 100 SF SOCIAL WORKER 100 SF APS DIR. OFFICE 99 SF I&R SUPERVISOR I&R ID STAFF (2) 120 SF ASST. ADMIN. 48 SF COPY/ PRINT 82 SF RECORDS 60 SF ADMIN. COOR. 110 SF SOCIAL WORKER 120 SF ADMIN. OFFICE 285 SF DRIVER'S LOUNGE 102 SF NUTR. DIR. OFFICE 102 SF HOME. DIR. 80 SF SNR. NUTR. AIDE 83 SF SUPPLIES 100 SF APS CASE WORKER 50 SF OFFICE ADMIN. 50 SF NUTR. ADMIN ASST 97 SF COPY/ PRINT 99 SF APS CASE WORKER 50 SF FGRS ADMIN ASST. 50 SF SCEP ADMIN. ASST. 80 SF FCP CASE WORKER HOME. AIDES 91 SF NUTR. AIDES 55 SF RECORDS 120 SF ADMIN. OFFICE 102 SF SCEP. DIR. OFFICE 108 SF FGRS DIR. OFFICE 102 SF FCP ASST DIR. OFFICE 100 SF TRANSPORT. DIR. OFFICE 100 SF APS CASE WORKER 99 SF APS CASE WORKER 100 SF APS CASE WORKER 84 SF WAITING ROOM 810 SF PUMPS & EQUIPMENT 1200 SF FIRE & DOMESTIC CISTERNS 64 SF U STAFF 100 SF SHARED BREAKROOM 222 SF SHARED CONF. ROOM 100 SF ELEVATOR 288 SF STAIR 3 89 SF LOBBY 288 SF STAIR 2 DOOR DOOR 144 SF WORKSHOP 100 SF ELEVATOR 90 SF ELEVATOR 10 11 12 12 18 12 OPTION FOR DISCUSSION 288 SF STAIR 3 A7 C1 A8 C1 A8 A1 A7 A1 B1 A10 A1 A10 OPEN SPACE WORKSTATION/LOBBY NET SF ENCLOSED ROOM/ PRIVATE OFFICE NET SF UTILITY SPACE/ BUILDING SYSTEMS SHARED AMENITY NORTH REVISIONS: DRAWN BY: CHECKED BY: DATE: NOVUS JOB NUMBER SHEET NUMBER A B C D E ALL INFORMATION CONTAINED HEREIN IS THE PROPERTY OF SPRINGLINE ARCHITECTS L.L.C. THE CONCEPTS, IDEAS, DESIGNS AND DETAILS AS SHOWN ON THE DOCUMENTS WERE CREATED, DEVELOPED, AND PRESENTED FOR USE ON THIS SPECIFIC PROJECT AND SHALL NOT BE REUSED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN CONSENT OF SPRINGLINE ARCHITECTS L.L.C. THE OWNER SHALL BE PERMITTED TO RETAIN COPIES FOR INFORMATION AND REFERENCE PURPOSES ONLY. 1 2 3 4 5 1 2 3 4 5 NOT FOR CONSTRUCTION INPROGRESS DOCUMENTS FOR INTERIM REVIEW ONLY. NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION. SUBMISSIONS: Ref Description Date A Programming B 60% CDs C 90% CDs D 100% CDs E 30% CDs ODR TASK ORDER NUMBER A2 10/15/2025 KB HK 1303 Hospital Ground St. Thomas, US. Virgin Islands 00802 KNUD HANSEN COMPLEX LOWER FLOOR SPACE PLAN PROGRAMMING PHASE 470-23-49, -50 010-9-101981 & 010-8-101472 10/15/2025 3/32" = 1'-0" A2 LOWER FLOOR SPACE PLAN A1 SPACE BLOCKS LOWER Space Name Programmed Area Provided Area Notes DHS CUST. 50 SF 52 SF ELECTRICAL 100 SF 80 SF ELEVATOR 100 SF 100 SF ELEVATOR 100 SF 100 SF F PUBLIC 65 SF 61 SF IT 100 SF 72 SF M PUBLIC 65 SF 61 SF MECHANICAL 168 SF 154 SF SHARED BREAKROOM 100 SF 100 SF SHARED CONF. ROOM 180 SF 222 SF SEAT 12 U STAFF 65 SF 64 SF DIPS COPY/ PRINT 64 SF 47 SF DETAINEE TOILET 64 SF 48 SF DISTRICT MGR 120 SF 121 SF HOLDING ROOM 80 SF 80 SF RECEPTION 80 SF 80 SF RECORDS 80 SF 82 SF SOCIAL WORKER 100 SF 100 SF SOCIAL WORKER 100 SF 100 SF SOCIAL WORKER 100 SF 100 SF FUTURE SOCIAL WORKER 100 SF 100 SF SOCIAL WORKER 100 SF 100 SF FUTURE DOH ELEVATOR 100 SF 90 SF LOBBY 150 SF 89 SF JOINT FIRE & DOMESTIC CISTERNS 1200 SF 1200 SF PUMPS & EQUIPMENT 0 SF 810 SF STAIR 2 240 SF 288 SF OPS COOLER 96 SF 96 SF 8x12 CUST. SUPPLY 100 SF 100 SF CUSTODIAL OFFICE 120 SF 120 SF DIRECTOR 80 SF 100 SF DRIVER'S LOUNGE 325 SF 285 SF SEAT 11 FREEZER 100 SF 100 SF 8x8 MAINT. STAFF 50 SF 50 SF MAINT. STAFF 50 SF 50 SF MAINT. STAFF 50 SF 50 SF MAINT. STAFF 50 SF 50 SF MAINT. STAFF 50 SF 50 SF MAINT. STAFF 50 SF 50 SF SUPPLIES 80 SF 82 SF TOOLS 100 SF 102 SF TRANSPORT. DIR. OFFICE 80 SF 100 SF WORKSHOP 144 SF 144 SF 12x12 RSICA ADMIN. COOR. 50 SF 60 SF ADMIN. OFFICE 120 SF 120 SF COPY/ PRINT 50 SF 48 SF RECORDS 100 SF 82 SF SOCIAL WORKER 100 SF 110 SF SCA ADMIN. OFFICE 120 SF 120 SF APS CASE WORKER 100 SF 100 SF APS CASE WORKER 100 SF 99 SF FUTURE APS CASE WORKER 100 SF 99 SF FUTURE APS CASE WORKER 100 SF 100 SF APS CASE WORKER 100 SF 100 SF APS DIR. OFFICE 100 SF 100 SF ASST. ADMIN. 120 SF 120 SF COPY/ PRINT 100 SF 97 SF FCP ASST DIR. OFFICE 100 SF 102 SF FCP CASE WORKER 80 SF 80 SF FGRS ADMIN ASST. 50 SF 50 SF FGRS DIR. OFFICE 100 SF 108 SF HOME. AIDES 105 SF 102 SF SEAT 7 HOME. DIR. 100 SF 102 SF I&R ID STAFF (2) 120 SF 140 SF 1 FUTURE I&R SUPERVISOR 100 SF 99 SF NUTR. ADMIN ASST 50 SF 50 SF NUTR. AIDES 90 SF 91 SF SEAT 6 NUTR. DIR. OFFICE 100 SF 102 SF OFFICE ADMIN. 50 SF 50 SF RECORDS 60 SF 55 SF SCEP ADMIN. ASST. 50 SF 50 SF SCEP. DIR. OFFICE 100 SF 102 SF SNR. NUTR. AIDE 80 SF 80 SF SUPPLIES 100 SF 83 SF WAITING ROOM 80 SF 84 SF No. Description Date NORTH C1 A9 A1 A9 100 SF COUNSELOR 48 SF FILES 123 SF MULTIP. 70 SF WAITING ROOM 100 SF COUNSELOR 70 SF AMBUL. WC 13 SF SUPPLIES 120 SF DISTRICT MGR 100 SF REHAB AID 100 SF O/B SPEC. 251 SF SHARED CONF. ROOM 80 SF RECEPT. 84 SF VENDOR SETUP 56 SF EE CLERK 72 SF EE CASE WRKR 72 SF EE CASE WRKR 72 SF EE CASE WRKR 72 SF EE CASE WRKR 49 SF CC ADMIN 80 SF CC CASE WRK 100 SF CC SUPER 100 SF EE SUPER 100 SF EE SUPER 120 SF DIRECTOR CERT. 49 SF ADMIN ASST 121 SF DIRECTOR SUPPORT 72 SF ELIG. SPEC. 110 SF ELIG. SUPER 49 SF ADMIN. OFFICER 80 SF ELECTRICAL 258 SF SHARED BREAKROOM 40 SF VENDING MACHINES 100 SF ELEVATOR 288 SF STAIR 3 1559 SF CONGREGATE ROOM 304 SF SHARED OFFICE (5) 120 SF DIRECTOR 52 SF COMP. LAB 56 SF INFO CLERK 56 SF INFO CLERK 43 SF SUPPLIES 56 SF INFO CLERK 56 SF EE CLERK 20 SF SECURITY 256 SF KITCHEN 97 SF TABLE STORAGE 100 SF NURSE 108 SF SECURITY OFFICE 64 SF EBT TECH 102 SF ISSUANCE SUPER 56 SF INFO CLERK 117 SF PANTRY 97 SF RESTROOM 97 SF RESTROOM 145 SF BREAKOUT 147 SF BREAKOUT 150 SF ADMINISTRATOR 100 SF COUNSELOR 100 SF TRANS. COOR. 100 SF COUNSELOR 54 SF EXEC ASST. 90 SF CLAIMS/ ISSUA. LOBBY 80 SF CLAIMS TELLER 131 SF ISSUANCE RECORDS 52 SF CLAIMS TELLER 221 SF SYSTEMS ANALYSTS (3) 64 SF EBT TECH 64 SF EBT TECH 48 SF SS ADMIN ASST 72 SF ELIG. SPEC. 72 SF ELIG. SPEC. 114 SF CLAIMS RECORDS 101 SF ELIG. RECORDS 72 SF EE CASE WRKR 72 SF EE CASE WRKR 72 SF EE CASE WRKR 47 SF FILES 72 SF EE CASE WRKR 72 SF EE CASE WRKR 72 SF EE CASE WRKR 72 SF EE CASE WRKR 72 SF EE CASE WRKR 76 SF SUPPLIES 72 SF ELIG. SPEC. 72 SF ELIG. SPEC. ELIG. SPEC. 72 SF ELIG. SPEC. 72 SF ELIG. SPEC. 72 SF ELIG. SPEC. 72 SF ELIG. SPEC. 72 SF ELIG. SPEC. 72 SF ELIG. SPEC. 300 SF SHARED LOBBY 160 SF IT MAIN DHS LOBBY 288 SF STAIR 2 563 SF PATIO 110 SF ELIG. SUPER 110 SF ELIG. SUPER STAFF ONLY 72 SF EE CASE WRKR 90 SF SHARED WORKROOM 80 SF CC CASE WRK CHILLERS GENERATOR 100 SF ELEVATOR 90 SF ELEVATOR 132 SF MECHANICAL 140 SF PUBLIC TOILETS 140 SF PUBLIC TOILETS 52 SF LACTATION 117 SF STAFF TOILETS 220 SF MECHANICAL 129 SF STAFF TOILETS 48 SF CUSTODIAL 1. refrigerator 2. standup freezer 3. ice machine 4. 6 burner gas stove 5. microwave 6. toaster oven 7. coffee pots 2 1 cleaning cooking service 4 7 3 6 5 prep A7 C1 A8 C1 A8 A1 A7 A1 B1 A10 A1 A10 OPEN SPACE WORKSTATION/LOBBY NET SF ENCLOSED ROOM/ PRIVATE OFFICE NET SF UTILITY SPACE/ BUILDING SYSTEMS SHARED AMENITY 3/32" = 1'-0" A3 MAIN FLOOR SPACE PLAN A1 REVISIONS: DRAWN BY: CHECKED BY: DATE: NOVUS JOB NUMBER SHEET NUMBER A B C D E ALL INFORMATION CONTAINED HEREIN IS THE PROPERTY OF SPRINGLINE ARCHITECTS L.L.C. THE CONCEPTS, IDEAS, DESIGNS AND DETAILS AS SHOWN ON THE DOCUMENTS WERE CREATED, DEVELOPED, AND PRESENTED FOR USE ON THIS SPECIFIC PROJECT AND SHALL NOT BE REUSED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN CONSENT OF SPRINGLINE ARCHITECTS L.L.C. THE OWNER SHALL BE PERMITTED TO RETAIN COPIES FOR INFORMATION AND REFERENCE PURPOSES ONLY. 1 2 3 4 5 1 2 3 4 5 NOT FOR CONSTRUCTION INPROGRESS DOCUMENTS FOR INTERIM REVIEW ONLY. NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION. SUBMISSIONS: Ref Description Date A Programming B 60% CDs C 90% CDs D 100% CDs E 30% CDs ODR TASK ORDER NUMBER A3 10/15/2025 KB HK 1303 Hospital Ground St. Thomas, US. Virgin Islands 00802 KNUD HANSEN COMPLEX MAIN FLOOR SPACE PLAN PROGRAMMING PHASE 470-23-49, -50 010-9-101981 & 010-8-101472 10/15/2025 SPACE BLOCKS MAIN Space Name Programmed Area Provided Area Notes DFA ADMIN ASST 50 SF 49 SF ADMIN. OFFICER 50 SF 49 SF DIRECTOR CERT. 120 SF 120 SF ELIG. RECORDS 120 SF 101 SF ELIG. SPEC. 80 SF 72 SF ELIG. SPEC. 80 SF 72 SF ELIG. SPEC. 80 SF 72 SF ELIG. SPEC. 80 SF 72 SF ELIG. SPEC. 80 SF 72 SF ELIG. SPEC. 80 SF 72 SF ELIG. SPEC. 80 SF 72 SF ELIG. SPEC. 80 SF 72 SF FUTURE ELIG. SPEC. 80 SF 72 SF ELIG. SPEC. 80 SF 72 SF ELIG. SPEC. 80 SF 72 SF ELIG. SPEC. 80 SF 72 SF ELIG. SUPER 120 SF 110 SF ELIG. SUPER 120 SF 110 SF ELIG. SUPER 120 SF 110 SF INFO CLERK 50 SF 56 SF INFO CLERK 50 SF 56 SF INFO CLERK 50 SF 56 SF INFO CLERK 50 SF 56 SF SHARED LOBBY 300 SF 300 SF SUPPLIES 50 SF 43 SF DFA SUPPORT SERVICES CLAIMS RECORDS 120 SF 114 SF CLAIMS TELLER 80 SF 80 SF CLAIMS TELLER 50 SF 52 SF FUTURE CLAIMS/ ISSUA. LOBBY 100 SF 90 SF DIRECTOR SUPPORT 120 SF 121 SF FUTURE EBT TECH 80 SF 64 SF EBT TECH 80 SF 64 SF EBT TECH 80 SF 64 SF FUTURE ISSUANCE RECORDS 150 SF 131 SF ISSUANCE SUPER 100 SF 102 SF SS ADMIN ASST 50 SF 48 SF FUTURE SYSTEMS ANALYSTS (3) 240 SF 221 SF DHS CUSTODIAL 60 SF 48 SF ELECTRICAL 100 SF 80 SF IT 100 SF 160 SF LACTATION 50 SF 52 SF MECHANICAL 308 SF 220 SF PUBLIC TOILETS 120 SF 140 SF PUBLIC TOILETS 120 SF 140 SF RECEPT. 80 SF 80 SF SECURITY OFFICE 100 SF 108 SF SHARED BREAKROOM 350 SF 258 SF SHARED CONF. ROOM 215 SF 251 SF SEAT 10 STAFF TOILETS 150 SF 117 SF STAFF TOILETS 150 SF 129 SF VENDING MACHINES 30 SF 40 SF VENDOR SETUP 100 SF 84 SF DOH LOBBY 150 SF 115 SF MECHANICAL 132 SF 132 SF MAP CC ADMIN 50 SF 49 SF CC CASE WRK 80 SF 80 SF CC CASE WRK 80 SF 80 SF CC SUPER 100 SF 100 SF SECURITY 20 SF 20 SF SHARED WORKROOM 100 SF 90 SF SUPPLIES 100 SF 76 SF MAP ELIG/ENROLL EE CASE WRKR 80 SF 72 SF EE CASE WRKR 80 SF 72 SF EE CASE WRKR 80 SF 72 SF FUTURE EE CASE WRKR 80 SF 72 SF EE CASE WRKR 80 SF 72 SF EE CASE WRKR 80 SF 72 SF EE CASE WRKR 80 SF 72 SF EE CASE WRKR 80 SF 72 SF EE CASE WRKR 80 SF 72 SF EE CASE WRKR 80 SF 72 SF EE CASE WRKR 80 SF 72 SF EE CASE WRKR 80 SF 72 SF FUTURE EE CASE WRKR 80 SF 72 SF FUTURE EE CLERK 80 SF 56 SF EE CLERK 80 SF 56 SF FUTURE EE SUPER 100 SF 100 SF FUTURE EE SUPER 100 SF 100 SF FILES 50 SF 47 SF STRIVE BREAKOUT 150 SF 145 SF BREAKOUT 150 SF 147 SF COMP. LAB 50 SF 52 SF CONGREGATE ROOM 1875 SF 1559 SF DIRECTOR 120 SF 120 SF KITCHEN 200 SF 256 SF NURSE 100 SF 100 SF PANTRY 100 SF 117 SF PATIO 200 SF 563 SF RESTROOM 110 SF 97 SF RESTROOM 110 SF 97 SF SHARED OFFICE (5) 300 SF 304 SF 2 FUTURE TABLE STORAGE 100 SF 97 SF VOC. REHAB ADMINISTRATOR 150 SF 150 SF AMBUL. WC 70 SF 70 SF COUNSELOR 100 SF 100 SF COUNSELOR 100 SF 100 SF COUNSELOR 100 SF 100 SF COUNSELOR 100 SF 100 SF DISTRICT MGR 120 SF 120 SF EXEC ASST. 50 SF 54 SF FILES 80 SF 48 SF MULTIP. 135 SF 123 SF O/B SPEC. 100 SF 100 SF REHAB AID 100 SF 100 SF SUPPLIES 30 SF 13 SF TRANS. COOR. 100 SF 100 SF WAITING ROOM 80 SF 70 SF No. Description Date C1 A9 A1 A9 81 SF DISTRICT MGR PS 180 SF ADMINISTRATOR 81 SF OFFICE MGR 81 SF DISTRICT MGR FC 81 SF FAMILY SERV. SPEC. PS 80 SF FAMILY SERV. SPEC. FC 214 SF VISITATION ROOM 80 SF LIC. SPECIALIST 80 SF CASE WORKER PS 80 SF CASE WORKER FC 110 SF RECORDS 150 SF DONATIONS 37 SF IT / UTILITY 110 SF EDUC. SUPER. 150 SF ADMINISTRATOR 110 SF DISAB. COOR. 120 SF ADMINISTRATOR 100 SF DIRECTOR 100 SF I&T SPECIALIST 207 SF FAMILY WAITING ROOM 50 SF RECEPTION 64 SF AIDES 64 SF AIDES 64 SF AIDES 64 SF AIDES 64 SF AIDES 64 SF AIDES 64 SF AIDES 64 SF AIDES 64 SF AIDES 64 SF AIDES 64 SF AIDES 64 SF AIDES 110 SF MENTAL HEALTH COOR. 110 SF EDUC. COOR. 110 SF PARENT INV. COOR. 56 SF QUAL. SPECIALIST 56 SF QUAL. SPECIALIST 50 SF OFFICE ASST. 56 SF LICENSING 56 SF CCR SPECIALIST 56 SF LICENSING 56 SF PROC. COORD. 64 SF AIDES 64 SF AIDES 64 SF AIDES 64 SF AIDES 64 SF AIDES 64 SF AIDES 122 SF RECORDS 110 SF HEALTH COOR. 81 SF FAMILY SERV. SPEC. PS 288 SF STAIR 3 100 SF ELEVATOR 220 SF MECHANICAL 48 SF ELECTRICAL 129 SF STAFF TOILETS 117 SF STAFF TOILETS 48 SF IT 48 SF ELECTRICAL 200 SF STORAGE 288 SF STAIR 2 140 SF PUBLIC TOILETS 111 SF FLEX STATIONS 280 SF SHARED BREAKROOM 397 SF SHARED CONF. ROOM 48 SF TELECOM 49 SF LACTATION 140 SF PUBLIC TOILETS 48 SF CUSTODIAL 152 SF RECORDS 203 SF RECORDS EGRESS 30 SF SUPPLIES 267 SF CONFERENCE 55 SF STAFF TOILET 86 SF SECURITY 34 SF JAN. 51 SF LACTATION 62 SF STAFF TOILET 478 SF EQUIP. STORAGE LOBBY 64 SF CASHIER (2) 109 SF STORAGE 65 SF PUBLIC TOILET 50 SF ADMIN ASST 70 SF WAITING ROOM 100 SF SOCIAL WORKER 100 SF SOCIAL WORKER 100 SF SOCIAL WORKER 100 SF SOCIAL WORKER 30 SF SUPPLIES 101 SF RECORDS 120 SF ADMIN OFFICE 100 SF INTERVIEW 100 SF INTERVIEW 120 SF DISTRICT MGR 80 SF FAMILY SERV. SPEC. FC 80 SF CASE WORKER PS 80 SF CASE WORKER FC 90 SF ELEVATOR 100 SF ELEVATOR 104 SF RECORDS 80 SF ADMIN. OFFICER 81 SF MED CASE MGR 80 SF ADMIN. SRVCS 80 SF SURVEIL. OFFICE 81 SF MED CASE MGR 116 SF DIR./ FLEX OFFICE 80 SF COORDINATOR OFFICE 80 SF TB COORD. OFFICE 80 SF SURVEIL. OFFICE 80 SF SURVEIL. OFFICE 80 SF LINK. CARE OFFICE 80 SF EPIDEM. OFFICE 100 SF SECURE STORAGE 80 SF OUTREACH 81 SF TELEHEALTH 80 SF DIS. INTERV. OFFICE 80 SF DIS. INTERV. OFFICE 35 SF MICROSCOPE 95 SF NURSE STATION 112 SF FLEX NURSING 59 SF CLEAN 150 SF ISOLATION ROOM 60 SF TRIAGE 69 SF RECORDS 56 SF HEAD NURSE 80 SF COMM HLTH WORKER 80 SF PHYSICIAN 80 SF PHYSICIAN 80 SF CLERICAL/ INTAKE 187 SF WAITING 100 SF VAX/RX STORAGE 40 SF VITALS 80 SF COUNSELING 64 SF SOILED 180 SF TREATMENT 80 SF PHYSICIAN 80 SF NP 80 SF DRESSING 100 SF EXAM 100 SF EXAM 100 SF EXAM 100 SF EXAM 56 SF CCR SPECIALIST 52 SF PUBLIC TOILET 120 SF PRENATAL EXAM 81 SF ADMIN. OFFICER 86 SF PROGRAM ADMIN. 80 SF CASE MANAGER 35 SF IT / UTILITY 150 SF ISOLATION ROOM 229 SF BREAKROOM 48 SF PATIENT TOILET 59 SF SUPPLIES MECHANICAL SHAFT PUBLIC ACCESS ESCORTED ACCESS NO ACCESS NO ACCESS NO ACCESS ESCORTED ACCESS 22 SF BIOHAZARD A7 C1 A8 C1 A8 A1 A7 A1 A1 A10 OPEN SPACE WORKSTATION/LOBBY NET SF ENCLOSED ROOM/ PRIVATE OFFICE NET SF UTILITY SPACE/ BUILDING SYSTEMS SHARED AMENITY NORTH REVISIONS: DRAWN BY: CHECKED BY: DATE: NOVUS JOB NUMBER SHEET NUMBER A B C D E ALL INFORMATION CONTAINED HEREIN IS THE PROPERTY OF SPRINGLINE ARCHITECTS L.L.C. THE CONCEPTS, IDEAS, DESIGNS AND DETAILS AS SHOWN ON THE DOCUMENTS WERE CREATED, DEVELOPED, AND PRESENTED FOR USE ON THIS SPECIFIC PROJECT AND SHALL NOT BE REUSED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN CONSENT OF SPRINGLINE ARCHITECTS L.L.C. THE OWNER SHALL BE PERMITTED TO RETAIN COPIES FOR INFORMATION AND REFERENCE PURPOSES ONLY. 1 2 3 4 5 1 2 3 4 5 NOT FOR CONSTRUCTION INPROGRESS DOCUMENTS FOR INTERIM REVIEW ONLY. NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION. SUBMISSIONS: Ref Description Date A Programming B 60% CDs C 90% CDs D 100% CDs E 30% CDs ODR TASK ORDER NUMBER A4 10/15/2025 KB HK 1303 Hospital Ground St. Thomas, US. Virgin Islands 00802 KNUD HANSEN COMPLEX SECOND FLOOR SPACE PLAN PROGRAMMING PHASE 470-23-49, -50 010-9-101981 & 010-8-101472 10/15/2025 3/32" = 1'-0" A4 SECOND FLOOR SPACE PLAN A1 SPACE BLOCKS SECOND DHS Space Name Programmed Area Provided Area Notes DHS CUSTODIAL 60 SF 48 SF ELECTRICAL 308 SF 48 SF FAMILY WAITING ROOM 200 SF 207 SF FLEX STATIONS 100 SF 111 SF LACTATION 50 SF 49 SF MECHANICAL 308 SF 220 SF PUBLIC TOILETS 120 SF 140 SF PUBLIC TOILETS 120 SF 140 SF SHARED BREAKROOM 100 SF 280 SF SHARED CONF. ROOM 200 SF 397 SF DIVIDABLE STAFF TOILETS 150 SF 117 SF STAFF TOILETS 150 SF 129 SF TELECOM 100 SF 48 SF DHS CHILD CARE REGULATION ADMINISTRATOR 120 SF 120 SF CCR SPECIALIST 50 SF 56 SF CCR SPECIALIST 50 SF 56 SF DIRECTOR 100 SF 100 SF I&T SPECIALIST 100 SF 100 SF LICENSING 50 SF 56 SF LICENSING 50 SF 56 SF OFFICE ASST. 50 SF 50 SF PROC. COORD. 50 SF 56 SF QUAL. SPECIALIST 50 SF 56 SF QUAL. SPECIALIST 50 SF 56 SF RECORDS 120 SF 122 SF STORAGE 200 SF 200 SF SUPPLIES 30 SF 30 SF DHS CHILDREN & FAMILY SERVICES ADMINISTRATOR 200 SF 180 SF CASE WORKER FC 80 SF 80 SF FUTURE CASE WORKER FC 80 SF 80 SF FUTURE CASE WORKER PS 80 SF 80 SF FUTURE CASE WORKER PS 80 SF 80 SF FUTURE DISTRICT MGR FC 100 SF 81 SF FUTURE DISTRICT MGR PS 100 SF 81 SF DONATIONS 150 SF 150 SF FAMILY SERV. SPEC. FC 80 SF 80 SF FAMILY SERV. SPEC. FC 80 SF 80 SF FAMILY SERV. SPEC. PS 80 SF 81 SF FAMILY SERV. SPEC. PS 80 SF 81 SF LIC. SPECIALIST 80 SF 80 SF FUTURE OFFICE MGR 100 SF 81 SF RECORDS 100 SF 110 SF STORAGE 100 SF 109 SF VISITATION ROOM 250 SF 214 SF DHS HEAD START ADMINISTRATOR 150 SF 150 SF AIDES 80 SF 64 SF AIDES 80 SF 64 SF AIDES 80 SF 64 SF AIDES 80 SF 64 SF AIDES 80 SF 64 SF AIDES 80 SF 64 SF AIDES 80 SF 64 SF AIDES 80 SF 64 SF AIDES 80 SF 64 SF AIDES 80 SF 64 SF AIDES 80 SF 64 SF AIDES 80 SF 64 SF AIDES 80 SF 64 SF AIDES 80 SF 64 SF AIDES 80 SF 64 SF AIDES 80 SF 64 SF AIDES 80 SF 64 SF AIDES 80 SF 64 SF DISAB. COOR. 120 SF 110 SF EDUC. COOR. 120 SF 110 SF EDUC. SUPER. 120 SF 110 SF EQUIP. STORAGE 750 SF 478 SF HEALTH COOR. 120 SF 110 SF IT / UTILITY 30 SF 37 SF MENTAL HEALTH COOR. 120 SF 110 SF PARENT INV. COOR. 120 SF 110 SF FUTURE RECEPTION 50 SF 50 SF RECORDS 250 SF 203 SF 750 total RECORDS 250 SF 152 SF 750 total RECORDS 250 SF 104 SF 750 total INTAKE ADMIN ASST 50 SF 50 SF ADMIN OFFICE 120 SF 120 SF DISTRICT MGR 100 SF 120 SF INTERVIEW 100 SF 100 SF INTERVIEW 100 SF 100 SF RECORDS 100 SF 101 SF SOCIAL WORKER 100 SF 100 SF SOCIAL WORKER 100 SF 100 SF SOCIAL WORKER 100 SF 100 SF SOCIAL WORKER 100 SF 100 SF SUPPLIES 30 SF 30 SF WAITING ROOM 60 SF 70 SF SPACE BLOCKS SECOND DOH Space Name Programmed Area Provided Area Notes DOH BREAKROOM 200 SF 229 SF CASHIER (2) 80 SF 64 SF CONFERENCE 400 SF 267 SF ELECTRICAL 48 SF 48 SF IT 48 SF 48 SF JAN. 40 SF 34 SF LACTATION 65 SF 51 SF PUBLIC TOILET 65 SF 65 SF PUBLIC TOILET 80 SF 52 SF SECURITY 80 SF 86 SF STAFF TOILET 65 SF 55 SF STAFF TOILET 80 SF 62 SF DOH COMMUNICABLE DISEASE ADMIN. OFFICER 100 SF 80 SF ADMIN. SRVCS 100 SF 80 SF COORDINATOR OFFICE 100 SF 80 SF DIR./ FLEX OFFICE 100 SF 116 SF DIS. INTERV. OFFICE 100 SF 80 SF DIS. INTERV. OFFICE 100 SF 80 SF EPIDEM. OFFICE 100 SF 80 SF LINK. CARE OFFICE 100 SF 80 SF MED CASE MGR 100 SF 81 SF MED CASE MGR 100 SF 81 SF MICROSCOPE 50 SF 35 SF OUTREACH 80 SF 80 SF SECURE STORAGE 100 SF 100 SF SURVEIL. OFFICE 100 SF 80 SF SURVEIL. OFFICE 100 SF 80 SF SURVEIL. OFFICE 100 SF 80 SF TB COORD. OFFICE 100 SF 80 SF TELEHEALTH 80 SF 81 SF DOH COMMUNITY HEALTH ADMIN. OFFICER 100 SF 81 SF BIOHAZARD 30 SF 22 SF CASE MANAGER 100 SF 80 SF CLEAN 50 SF 59 SF CLERICAL/ INTAKE 80 SF 80 SF COMM HLTH WORKER 100 SF 80 SF COUNSELING 80 SF 80 SF DRESSING 65 SF 80 SF EXAM 100 SF 100 SF EXAM 100 SF 100 SF EXAM 100 SF 100 SF EXAM 100 SF 100 SF FLEX NURSING 80 SF 112 SF HEAD NURSE 65 SF 56 SF ISOLATION ROOM 80 SF 150 SF ISOLATION ROOM 80 SF 150 SF IT / UTILITY 40 SF 35 SF NP 65 SF 80 SF NURSE STATION 150 SF 95 SF PATIENT TOILET 80 SF 48 SF PHYSICIAN 100 SF 80 SF PHYSICIAN 100 SF 80 SF PHYSICIAN 100 SF 80 SF PRENATAL EXAM 100 SF 120 SF PROGRAM ADMIN. 100 SF 86 SF RECORDS 0 SF 69 SF SOILED 80 SF 64 SF SUPPLIES 50 SF 59 SF TREATMENT 80 SF 180 SF TRIAGE 50 SF 60 SF VAX/RX STORAGE 100 SF 100 SF VITALS 40 SF 40 SF WAITING 150 SF 187 SF No. Description Date C1 A9 A1 A9 192 SF CPO 110 SF DIRECTOR 110 SF AUDIT DIRECTOR 110 SF DIRECTOR 247 SF CFO 64 SF FED. FIN. ANALYST 64 SF FED. FIN. ANALYST 64 SF FED. FIN. ANALYST 64 SF AP SPECIALIST 125 SF CONFERENCE 110 SF DIRECTOR 34 SF SUPPLIES 71 SF PROCUREMENT 50 SF AC. ASST. 50 SF COMM. ASST. 255 SF COMMISSIONER 255 SF CONFERENCE 212 SF STT/STJ AC PRIVATE WC 30 SF SUPPLIES 192 SF STX AC 189 SF LEGAL COUNSEL 104 SF INTERNAL BREAKROOM 95 SF DIR. COMMUNITY ENGAGE. CONTRACT ADMIN (2) 53 SF RECEPTION 180 SF DEPUTY COMMISSIONER 80 SF GENERALIST 78 SF GENERALIST LABOR RELATIONS 51 SF ADMIN ASST WAITING ROOM 66 SF RECORDS 52 SF EXEC ASST. 51 SF HR ASST 102 SF STX DC OFFICE 80 SF ASST. DC 192 SF DEPUTY COMMISSIONER 50 SF ADMIN ASST 64 SF FIN. ANALYST GF 64 SF AP SPECIALIST 77 SF ACCT. PAYABLE 64 SF PAYROLL CLERK 64 SF AP SPECIALIST 64 SF FED. GRANT COOR. 64 SF CONTROL AUDIT. 28 SF MESSENGER 28 SF RECEPTION 73 SF RECORDS 64 SF INVENTORY CLERK 64 SF FIN. ANALYST GF FED. FIN. ANALYST 64 SF FED. FIN. ANALYST 64 SF AP SPECIALIST 114 SF SPEC. ASST. PRIVATE WC 48 SF INTERNAL WORKROOM EXEC. PM 50 SF OFFICE ASST. 50 SF ADMIN ASST 50 SF MAIL ROOM 50 SF ADMIN ASST FED. FIN. ANALYST 49 SF FUTURE WRKSTN 110 SF ASSET DIRECTOR PRIVATE WC 80 SF CAPITAL PROJECTS 32 SF COPY/ PRINT 162 SF QC SUPER & REV. (2) MANAGEMENT EVAL 80 SF FRONT END INVESTIG. 80 SF FRONT END INVESTIG. 80 SF QC REVIEWER 80 SF QC REVIEWER 50 SF OFFICE MANAGER 31 SF JOBS WAITING 90 SF EMPLOY. TRAINING 90 SF EMPLOY. TRAINING 90 SF EMPLOY. TRAINING 318 SF JOBS LAB 110 SF DIRECTOR PR 110 SF DIRECTOR TANF 110 SF DISTRICT MGR 120 SF ADMINISTRATOR 50 SF QC ADMIN ASST 50 SF ADMIN ASST 52 SF SWITCH BOARD OP. 118 SF PREP (2) 44 SF PREP STORAGE 80 SF FRAUD INVESTIG. 1324 SF TRAINING ROOM 288 SF STAIR 2 213 SF SHARED BREAKROOM 48 SF TELECOM 200 SF KITCHEN 80 SF COMMS OFFICE 80 SF COMMS OFFICE FILES 50 SF STORAGE 80 SF FRAUD INVESTIG. 120 SF RECORDS 120 SF FRAUD RECORDS 80 SF PE SPEC. 80 SF PE SPEC. 80 SF QC REVIEWER 80 SF PE SPEC. 80 SF PE SPEC. 120 SF DIRECTOR 120 SF PI DIRECTOR 100 SF ASST. DIRECTOR 80 SF PI ANALYST 65 SF RECORDS 80 SF IT MANAGER 50 SF EXEC ASST. 39 SF WAITING 80 SF FRAUD INVESTIG. 46 SF ADA TOILET 184 SF CONFERENCE 20 SF COPY/ PRINT 100 SF ELEVATOR 100 SF ELEVATOR 288 SF STAIR 3 220 SF MECHANICAL 48 SF ELECTRICAL STAFF TOILETS STAFF TOILETS 140 SF PUBLIC TOILETS 54 SF LACTATION PUBLIC TOILETS 48 SF CUSTODIAL 71 SF PROCUREMENT 71 SF PROCUREMENT 66 SF ASSET STORAGE 90 SF TRAINING OFFICER 80 SF FRONT END INVESTIG. 55 SF STORAGE 147 SF SECURE STORAGE 120 SF DIRECTOR 50 SF ANALYST 50 SF NETWORK ANALYST 50 SF SYSTEMS ANALYST 50 SF HELP DESK 50 SF HELP DESK 100 SF SYSTEMS MANAGER 28 SF SUPPLIES 50 SF ADMIN ASST 200 SF COMP SETUP 204 SF COMP CENTER ELEVATOR SHAFT BELOW (SLA COORDINATION ITEM) 90 SF NETWORK MANAGER 5' - 6 1/2" 101 SF PAYROLL SUPER A7 C1 A8 C1 A8 A1 A7 A1 A1 A10 OPEN SPACE WORKSTATION/LOBBY NET SF ENCLOSED ROOM/ PRIVATE OFFICE NET SF UTILITY SPACE/ BUILDING SYSTEMS SHARED AMENITY NORTH 3/32" = 1'-0" A5 THIRD FLOOR SPACE PLAN A1 REVISIONS: DRAWN BY: CHECKED BY: DATE: NOVUS JOB NUMBER SHEET NUMBER A B C D E ALL INFORMATION CONTAINED HEREIN IS THE PROPERTY OF SPRINGLINE ARCHITECTS L.L.C. THE CONCEPTS, IDEAS, DESIGNS AND DETAILS AS SHOWN ON THE DOCUMENTS WERE CREATED, DEVELOPED, AND PRESENTED FOR USE ON THIS SPECIFIC PROJECT AND SHALL NOT BE REUSED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN CONSENT OF SPRINGLINE ARCHITECTS L.L.C. THE OWNER SHALL BE PERMITTED TO RETAIN COPIES FOR INFORMATION AND REFERENCE PURPOSES ONLY. 1 2 3 4 5 1 2 3 4 5 NOT FOR CONSTRUCTION INPROGRESS DOCUMENTS FOR INTERIM REVIEW ONLY. NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION. SUBMISSIONS: Ref Description Date A Programming B 60% CDs C 90% CDs D 100% CDs E 30% CDs ODR TASK ORDER NUMBER A5 10/15/2025 KB HK 1303 Hospital Ground St. Thomas, US. Virgin Islands 00802 KNUD HANSEN COMPLEX THIRD FLOOR SPACE PLAN PROGRAMMING PHASE 470-23-49, -50 010-9-101981 & 010-8-101472 10/15/2025 SPACE BLOCKS THIRD Space Name Programmed Area Provided Area Notes COMMUNICATIONS COMMS OFFICE 80 SF 80 SF COMMS OFFICE 80 SF 80 SF DFA ADMIN ASST 50 SF 50 SF FUTURE ADMINISTRATOR 120 SF 120 SF DIRECTOR PR 120 SF 110 SF DIRECTOR TANF 120 SF 110 SF DISTRICT MGR 120 SF 110 SF EMPLOY. TRAINING 120 SF 90 SF EMPLOY. TRAINING 120 SF 90 SF EMPLOY. TRAINING 120 SF 90 SF FRAUD INVESTIG. 120 SF 80 SF FRAUD INVESTIG. 120 SF 80 SF FRAUD RECORDS 120 SF 120 SF FRONT END INVESTIG. 80 SF 80 SF FRONT END INVESTIG. 80 SF 80 SF FUTURE FRONT END INVESTIG. 80 SF 80 SF JOBS LAB 300 SF 318 SF 20 SEATS JOBS WAITING 20 SF 31 SF MANAGEMENT EVAL 120 SF 118 SF OFFICE MANAGER 50 SF 50 SF PREP (2) 120 SF 118 SF PREP STORAGE 50 SF 44 SF QC ADMIN ASST 50 SF 50 SF FUTURE QC REVIEWER 80 SF 80 SF FUTURE QC REVIEWER 80 SF 80 SF FUTURE QC SUPER & REV. (2) 160 SF 162 SF RECORDS 120 SF 120 SF SWITCH BOARD OP. 50 SF 52 SF TRAINING OFFICER 120 SF 90 SF DHS CUSTODIAL 60 SF 48 SF ELECTRICAL 308 SF 48 SF KITCHEN 500 SF 200 SF LACTATION 50 SF 54 SF MECHANICAL 308 SF 220 SF PUBLIC TOILETS 120 SF 140 SF PUBLIC TOILETS 120 SF 140 SF SHARED BREAKROOM 100 SF 213 SF STAFF TOILETS 150 SF 117 SF STAFF TOILETS 150 SF 129 SF TELECOM 100 SF 48 SF TRAINING ROOM 1700 SF 1324 SF DHS MANAGEMENT INFO SYSTEMS ADMIN ASST 50 SF 50 SF FUTURE ANALYST 50 SF 50 SF FUTURE COMP CENTER 200 SF 204 SF COMP SETUP 200 SF 200 SF DIRECTOR 120 SF 120 SF HELP DESK 50 SF 50 SF FUTURE HELP DESK 50 SF 50 SF FUTURE NETWORK ANALYST 50 SF 50 SF NETWORK MANAGER 100 SF 90 SF SECURE STORAGE 150 SF 147 SF SUPPLIES 30 SF 28 SF SYSTEMS ANALYST 50 SF 50 SF SYSTEMS MANAGER 120 SF 100 SF FISCAL ACCT. PAYABLE 80 SF 77 SF FUTURE AP SPECIALIST 80 SF 64 SF AP SPECIALIST 80 SF 64 SF AP SPECIALIST 80 SF 64 SF AP SPECIALIST 80 SF 64 SF ASSET DIRECTOR 120 SF 110 SF ASSET STORAGE 60 SF 66 SF AUDIT DIRECTOR 200 SF 110 SF CFO 300 SF 247 SF CONFERENCE 120 SF 125 SF CONTROL AUDIT. 80 SF 64 SF FUTURE COPY/ PRINT 30 SF 32 SF CPO 200 SF 192 SF FUTURE DIRECTOR 200 SF 110 SF DIRECTOR 120 SF 110 SF DIRECTOR 120 SF 110 SF FED. FIN. ANALYST 80 SF 64 SF FED. FIN. ANALYST 80 SF 64 SF FED. FIN. ANALYST 80 SF 64 SF FED. FIN. ANALYST 80 SF 64 SF FUTURE FED. FIN. ANALYST 80 SF 64 SF FED. FIN. ANALYST 80 SF 64 SF FED. GRANT COOR. 80 SF 64 SF FIN. ANALYST GF 80 SF 64 SF FUTURE FIN. ANALYST GF 80 SF 64 SF FUTURE INVENTORY CLERK 80 SF 64 SF MESSENGER 50 SF 28 SF PAYROLL CLERK 80 SF 64 SF PAYROLL SUPER 80 SF 101 SF PRIVATE WC 30 SF 28 SF RECEPTION 50 SF 28 SF RECORDS 80 SF 73 SF SPEC. ASST. 120 SF 114 SF SUPPLIES 30 SF 34 SF SPACE BLOCKS THIRD Space Name Programmed Area Provided Area Notes HR ADMIN ASST 50 SF 51 SF CONFERENCE 200 SF 184 SF COPY/ PRINT 80 SF 20 SF DEPUTY COMMISSIONER 200 SF 180 SF EXEC ASST. 50 SF 52 SF FUTURE WRKSTN 50 SF 49 SF FUTURE GENERALIST 100 SF 80 SF GENERALIST 100 SF 78 SF HR ASST 50 SF 51 SF LABOR RELATIONS 100 SF 117 SF RECORDS 100 SF 66 SF WAITING ROOM 40 SF 42 SF 3 SEATS MAP ASST. DIRECTOR 120 SF 100 SF DIRECTOR 120 SF 120 SF EXEC ASST. 50 SF 50 SF FRAUD INVESTIG. 80 SF 80 SF FUTURE IT MANAGER 80 SF 80 SF FUTURE PE SPEC. 80 SF 80 SF PE SPEC. 80 SF 80 SF PE SPEC. 80 SF 80 SF FUTURE PE SPEC. 80 SF 80 SF PI ANALYST 80 SF 80 SF FUTURE PI DIRECTOR 120 SF 120 SF QC REVIEWER 80 SF 80 SF FUTURE RECORDS 50 SF 65 SF STORAGE 60 SF 55 SF WAITING 50 SF 39 SF 3 SEATS OOC AC. ASST. 50 SF 50 SF ADA TOILET 40 SF 46 SF ADMIN ASST 50 SF 50 SF FUTURE ADMIN ASST 50 SF 50 SF FUTURE COMM. ASST. 50 SF 50 SF COMMISSIONER 250 SF 255 SF CONFERENCE 250 SF 255 SF SEAT 10 CONTRACT ADMIN (2) 120 SF 131 SF 1 FUTURE DIR. COMMUNITY ENGAGE. 120 SF 95 SF EXEC. PM 80 SF 80 SF FILES 50 SF 34 SF INTERNAL BREAKROOM 120 SF 104 SF INTERNAL WORKROOM 100 SF 48 SF LEGAL COUNSEL 200 SF 189 SF MAIL ROOM 50 SF 50 SF OFFICE ASST. 50 SF 50 SF PRIVATE WC 50 SF 28 SF PRIVATE WC 50 SF 30 SF PROCUREMENT 80 SF 71 SF FUTURE PROCUREMENT 80 SF 71 SF FUTURE PROCUREMENT 80 SF 71 SF FUTURE RECEPTION 50 SF 53 SF STT/STJ AC 250 SF 212 SF STX AC 200 SF 192 SF SUPPLIES 30 SF 30 SF OPS ADMIN ASST 50 SF 50 SF ASST. DC 80 SF 80 SF CAPITAL PROJECTS 80 SF 80 SF FUTURE DEPUTY COMMISSIONER 200 SF 192 SF STORAGE 50 SF 50 SF STX DC OFFICE 100 SF 102 SF No. Description Date DN UP UP UP DN DN DN UP DN NORTH 1 2 3 4 5 6 7 8 1.1 8.1 A E A.1 C D B D.1 A.2 B.1 C.1 20' - 0" 19' - 0" 31' - 6" 31' - 6" 31' - 6" 31' - 6" 31' - 6" 26' - 6" 10' - 0" 8' - 0" 19' - 6" 23' - 10" 23' - 10" 23' - 10" 11' - 0" 27' - 6" 27' - 6" 27' - 6" 27' - 6" 27' - 6" 71' - 6" 20' - 0 1/4" 110' - 0" 15' - 0" 12' - 6" 71' - 6" 11' - 0" 233' - 0" 1 2 3 4 5 6 7 8 1.1 8.1 A E A.1 C D B D.1 A.2 B.1 C.1 233' - 0" 20' - 0" 19' - 0" 31' - 6" 31' - 6" 31' - 6" 31' - 6" 31' - 6" 26' - 6" 10' - 0" 8' - 0" 19' - 6" 23' - 10" 23' - 10" 23' - 10" 11' - 0" 27' - 6" 27' - 6" 27' - 6" 27' - 6" 27' - 6" 71' - 6" 20' - 0 1/4" 110' - 0" 15' - 0" 12' - 6" 71' - 6" 11' - 0" 233' - 0" 1 2 3 4 5 6 7 8 1.1 8.1 A E A.1 C D B D.1 A.2 B.1 C.1 G.D G.C G.B G.A G.E G.1 G.2 G.3 G.4 G.5 G.6 12' - 0" 36' - 0" 30' - 0" 36' - 0" 15' - 0" 20' - 0" 19' - 0" 31' - 6" 31' - 6" 31' - 6" 31' - 6" 31' - 6" 26' - 6" 10' - 0" 8' - 0" 19' - 6" 23' - 10" 23' - 10" 23' - 10" 11' - 0" 129' - 0" 110' - 0" 233' - 0" 114' - 0" 23' - 0" 102' - 0" 239' - 0" 36' - 0" 38' - 0" 36' - 0" 46' - 0" 46' - 0" 202' - 0" 1 2 3 4 5 6 7 8 1.1 8.1 A E A.1 C D B D.1 A.2 B.1 C.1 G.D G.C G.B G.A G.E G.1 G.2 G.3 G.4 G.5 G.6 12' - 0" 36' - 0" 30' - 0" 36' - 0" 15' - 0" 36' - 0" 38' - 0" 36' - 0" 46' - 0" 46' - 0" 20' - 0" 19' - 0" 31' - 6" 31' - 6" 31' - 6" 31' - 6" 31' - 6" 26' - 6" 10' - 0" 8' - 0" 19' - 6" 23' - 10" 23' - 10" 23' - 10" 11' - 0" 129' - 0" 110' - 0" 233' - 0" 114' - 0" 23' - 0" 102' - 0" 239' - 0" 202' - 0" REVISIONS: DRAWN BY: CHECKED BY: DATE: NOVUS JOB NUMBER SHEET NUMBER A B C D E ALL INFORMATION CONTAINED HEREIN IS THE PROPERTY OF SPRINGLINE ARCHITECTS L.L.C. THE CONCEPTS, IDEAS, DESIGNS AND DETAILS AS SHOWN ON THE DOCUMENTS WERE CREATED, DEVELOPED, AND PRESENTED FOR USE ON THIS SPECIFIC PROJECT AND SHALL NOT BE REUSED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN CONSENT OF SPRINGLINE ARCHITECTS L.L.C. THE OWNER SHALL BE PERMITTED TO RETAIN COPIES FOR INFORMATION AND REFERENCE PURPOSES ONLY. 1 2 3 4 5 1 2 3 4 5 NOT FOR CONSTRUCTION INPROGRESS DOCUMENTS FOR INTERIM REVIEW ONLY. NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION. SUBMISSIONS: Ref Description Date A Programming B 60% CDs C 90% CDs D 100% CDs E 30% CDs ODR TASK ORDER NUMBER A6 10/15/2025 KB HK 1303 Hospital Ground St. Thomas, US. Virgin Islands 00802 KNUD HANSEN COMPLEX BUILDING SHELL PLANS PROGRAMMING PHASE 470-23-49, -50 010-9-101981 & 010-8-101472 10/15/2025 No. Description Date 1" = 20'-0" A6 LOWER FLOOR BUILDING SHELL PLAN C1 1" = 20'-0" A6 SECOND FLOOR BUILDING SHELL PLAN C4 1" = 20'-0" A6 THIRD FLOOR BUILDING SHELL PLAN A4 1" = 20'-0" A6 MAIN FLOOR BUILDING SHELL PLAN A1 1ST FLOOR 64' - 6" 2ND FLOOR 77' - 10" 3RD FLOOR 91' - 2" B.O. PARAPET 104' - 6" A E A.1 C D B D.1 A.2 B.1 C.1 G.D G.C G.B G.A G.E B1 A10 A1 A10 1ST FLOOR 64' - 6" 2ND FLOOR 77' - 10" BASEMENT 49' - 6" 3RD FLOOR 91' - 2" B.O. PARAPET 104' - 6" C1 A9 A1 A9 1 2 3 4 5 6 7 8 1.1 8.1 G.1 G.2 G.3 G.4 G.5 G.6 REVISIONS: DRAWN BY: CHECKED BY: DATE: NOVUS JOB NUMBER SHEET NUMBER A B C D E ALL INFORMATION CONTAINED HEREIN IS THE PROPERTY OF SPRINGLINE ARCHITECTS L.L.C. THE CONCEPTS, IDEAS, DESIGNS AND DETAILS AS SHOWN ON THE DOCUMENTS WERE CREATED, DEVELOPED, AND PRESENTED FOR USE ON THIS SPECIFIC PROJECT AND SHALL NOT BE REUSED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN CONSENT OF SPRINGLINE ARCHITECTS L.L.C. THE OWNER SHALL BE PERMITTED TO RETAIN COPIES FOR INFORMATION AND REFERENCE PURPOSES ONLY. 1 2 3 4 5 1 2 3 4 5 NOT FOR CONSTRUCTION INPROGRESS DOCUMENTS FOR INTERIM REVIEW ONLY. NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION. SUBMISSIONS: Ref Description Date A Programming B 60% CDs C 90% CDs D 100% CDs E 30% CDs ODR TASK ORDER NUMBER A7 10/15/2025 KB HK 1303 Hospital Ground St. Thomas, US. Virgin Islands 00802 KNUD HANSEN COMPLEX BUILDING ELEVATIONS PROGRAMMING PHASE 470-23-49, -50 010-9-101981 & 010-8-101472 10/15/2025 3/32" = 1'-0" A7 BUILDING ELEVATION - NORTH C1 3/32" = 1'-0" A7 BUILDING ELEVATION - EAST A1 No. Description Date 1ST FLOOR 64' - 6" 2ND FLOOR 77' - 10" BASEMENT 49' - 6" 3RD FLOOR 91' - 2" B.O. PARAPET 104' - 6" A E A.1 C D B D.1 A.2 B.1 C.1 G.D G.C G.B G.A G.E B1 A10 A1 A10 1ST FLOOR 64' - 6" 2ND FLOOR 77' - 10" BASEMENT 49' - 6" 3RD FLOOR 91' - 2" B.O. PARAPET 104' - 6" C1 A9 A1 A9 1 2 3 4 5 6 7 8 1.1 8.1 G.1 G.2 G.3 G.4 G.5 G.6 REVISIONS: DRAWN BY: CHECKED BY: DATE: NOVUS JOB NUMBER SHEET NUMBER A B C D E ALL INFORMATION CONTAINED HEREIN IS THE PROPERTY OF SPRINGLINE ARCHITECTS L.L.C. THE CONCEPTS, IDEAS, DESIGNS AND DETAILS AS SHOWN ON THE DOCUMENTS WERE CREATED, DEVELOPED, AND PRESENTED FOR USE ON THIS SPECIFIC PROJECT AND SHALL NOT BE REUSED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN CONSENT OF SPRINGLINE ARCHITECTS L.L.C. THE OWNER SHALL BE PERMITTED TO RETAIN COPIES FOR INFORMATION AND REFERENCE PURPOSES ONLY. 1 2 3 4 5 1 2 3 4 5 NOT FOR CONSTRUCTION INPROGRESS DOCUMENTS FOR INTERIM REVIEW ONLY. NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION. SUBMISSIONS: Ref Description Date A Programming B 60% CDs C 90% CDs D 100% CDs E 30% CDs ODR TASK ORDER NUMBER A8 10/15/2025 KB HK 1303 Hospital Ground St. Thomas, US. Virgin Islands 00802 KNUD HANSEN COMPLEX BUILDING ELEVATIONS PROGRAMMING PHASE 470-23-49, -50 010-9-101981 & 010-8-101472 10/15/2025 3/32" = 1'-0" A8 BUILDING ELEVATION - SOUTH C1 3/32" = 1'-0" A8 BUILDING ELEVATION - WEST A1 No. Description Date 1ST FLOOR 64' - 6" 2ND FLOOR 77' - 10" BASEMENT 49' - 6" 3RD FLOOR 91' - 2" B.O. PARAPET 104' - 6" (B) - BUSINESS +/- 73,556 SF (S-2) - PARKING +/- 57,484 SF +/- 22,400 SF +/- 22,284 SF +/- 17,542 SF +/- 25,298 SF +/- 11,330 SF +/- 32,186 SF CHILLER MAIN LEVEL ENTRY VESTIBULE BEYOND A E A.1 C D B D.1 A.2 B.1 C.1 G.D G.C G.B G.A G.E B1 A10 A1 A10 1ST FLOOR 64' - 6" 2ND FLOOR 77' - 10" BASEMENT 49' - 6" 3RD FLOOR 91' - 2" B.O. PARAPET 104' - 6" +/- 22,400 SF +/- 22,284 SF +/- 17,542 SF +/- 25,298 SF +/- 32,186 SF (B) - BUSINESS +/- 73,556 SF (S-2) - PARKING +/- 57,484 SF (B) - BUSINESS EXISTING 55' - 7" 64' - 9" A E A.1 C D B D.1 A.2 B.1 C.1 G.D G.C G.B G.A G.E B1 A10 A1 A10 CISTERN REVISIONS: DRAWN BY: CHECKED BY: DATE: NOVUS JOB NUMBER SHEET NUMBER A B C D E ALL INFORMATION CONTAINED HEREIN IS THE PROPERTY OF SPRINGLINE ARCHITECTS L.L.C. THE CONCEPTS, IDEAS, DESIGNS AND DETAILS AS SHOWN ON THE DOCUMENTS WERE CREATED, DEVELOPED, AND PRESENTED FOR USE ON THIS SPECIFIC PROJECT AND SHALL NOT BE REUSED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN CONSENT OF SPRINGLINE ARCHITECTS L.L.C. THE OWNER SHALL BE PERMITTED TO RETAIN COPIES FOR INFORMATION AND REFERENCE PURPOSES ONLY. 1 2 3 4 5 1 2 3 4 5 NOT FOR CONSTRUCTION INPROGRESS DOCUMENTS FOR INTERIM REVIEW ONLY. NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION. SUBMISSIONS: Ref Description Date A Programming B 60% CDs C 90% CDs D 100% CDs E 30% CDs ODR TASK ORDER NUMBER A9 10/15/2025 KB HK 1303 Hospital Ground St. Thomas, US. Virgin Islands 00802 KNUD HANSEN COMPLEX BUILDING SECTIONS PROGRAMMING PHASE 470-23-49, -50 010-9-101981 & 010-8-101472 10/15/2025 3/32" = 1'-0" A9 BUILDING SECTION A C1 3/32" = 1'-0" A9 BUILDING SECTION B A1 No. Description Date 1ST FLOOR 64' - 6" 2ND FLOOR 77' - 10" BASEMENT 49' - 6" 3RD FLOOR 91' - 2" B.O. PARAPET 104' - 6" C1 A9 A1 A9 1 2 3 4 5 6 7 8 1.1 8.1 (S-2) - PARKING +/- 57,484 SF +/- 25,298 SF +/- 32,186 SF 1ST FLOOR 64' - 6" 2ND FLOOR 77' - 10" BASEMENT 49' - 6" 3RD FLOOR 91' - 2" B.O. PARAPET 104' - 6" C1 A9 A1 A9 1 2 3 4 5 6 7 8 1.1 8.1 (B) - BUSINESS +/- 73,556 SF (S-2) - PARKING +/- 57,484 SF +/- 22,400 SF +/- 22,284 SF +/- 17,542 SF +/- 11,330 SF REVISIONS: DRAWN BY: CHECKED BY: DATE: NOVUS JOB NUMBER SHEET NUMBER A B C D E ALL INFORMATION CONTAINED HEREIN IS THE PROPERTY OF SPRINGLINE ARCHITECTS L.L.C. THE CONCEPTS, IDEAS, DESIGNS AND DETAILS AS SHOWN ON THE DOCUMENTS WERE CREATED, DEVELOPED, AND PRESENTED FOR USE ON THIS SPECIFIC PROJECT AND SHALL NOT BE REUSED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN CONSENT OF SPRINGLINE ARCHITECTS L.L.C. THE OWNER SHALL BE PERMITTED TO RETAIN COPIES FOR INFORMATION AND REFERENCE PURPOSES ONLY. 1 2 3 4 5 1 2 3 4 5 NOT FOR CONSTRUCTION INPROGRESS DOCUMENTS FOR INTERIM REVIEW ONLY. NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION. SUBMISSIONS: Ref Description Date A Programming B 60% CDs C 90% CDs D 100% CDs E 30% CDs ODR TASK ORDER NUMBER A10 10/15/2025 KB HK 1303 Hospital Ground St. Thomas, US. Virgin Islands 00802 KNUD HANSEN COMPLEX BUILDING SECTIONS PROGRAMMING PHASE 470-23-49, -50 010-9-101981 & 010-8-101472 10/15/2025 No. Description Date 3/32" = 1'-0" A10 BUILDING SECTION C B1 3/32" = 1'-0" A10 BUILDING SECTION D A1 REVISIONS: DRAWN BY: CHECKED BY: DATE: NOVUS JOB NUMBER SHEET NUMBER A B C D E ALL INFORMATION CONTAINED HEREIN IS THE PROPERTY OF SPRINGLINE ARCHITECTS L.L.C. THE CONCEPTS, IDEAS, DESIGNS AND DETAILS AS SHOWN ON THE DOCUMENTS WERE CREATED, DEVELOPED, AND PRESENTED FOR USE ON THIS SPECIFIC PROJECT AND SHALL NOT BE REUSED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN CONSENT OF SPRINGLINE ARCHITECTS L.L.C. THE OWNER SHALL BE PERMITTED TO RETAIN COPIES FOR INFORMATION AND REFERENCE PURPOSES ONLY. 1 2 3 4 5 1 2 3 4 5 NOT FOR CONSTRUCTION INPROGRESS DOCUMENTS FOR INTERIM REVIEW ONLY. NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION. SUBMISSIONS: Ref Description Date A Programming B 60% CDs C 90% CDs D 100% CDs E 30% CDs ODR TASK ORDER NUMBER A11 10/15/2025 KB HK 1303 Hospital Ground St. Thomas, US. Virgin Islands 00802 KNUD HANSEN COMPLEX 3D AXONS PROGRAMMING PHASE 470-23-49, -50 010-9-101981 & 010-8-101472 10/15/2025 1. AXONOMETRIC - NORTHEAST 2. AXONOMETRIC - NORTHWEST 3. AXONOMETRIC - SOUTHEAST 4. AXONOMETRIC - SOUTHWEST No. Description Date