PROJECT OWNER: DRAWINGS INCLUDED IN THIS PACKAGE DRAWING # DRAWING NAME ONE LINE DIAGRAM (PHASE 1) GENERAL CONSTRUCTION NOTES & ABBREVIATIONS ST-20131-9A-G-100 STT-20131-9A-E-100 ELECTRICAL ELECTRICAL DETAILS AND SCHEDULES STT-20131-9A-E-101 ST-20131-9A-E-400 ST-20131-9A-E-200 ELECTRICAL EQUIPMENT SCHEDULES ST-20131-9A-E-300 FEEDER 9A DUCT BANK PLAN ST-20131-9A-E-301 ST-20131-9A-E-302 FEEDER 9A DUCT BANK PLAN FEEDER 9A DUCT BANK PLAN ISSUE FOR EHP REVIEW ISSUE A: 06.24.2022 GROUNDING DETAILS STT-20131-9A-E-104 ST-20131-9A-TC-100 TRAFFIC CONTROL DETAILS ST-20131-9A-TC-101 TRAFFIC CONTROL SYMBOLS & DETAILS GENERAL CONSTRUCTION DETAILS ST-20131-9A-G-101 TRAFFIC CONTROL GENERAL ST-20131-9A-E-303 FEEDER 9A DUCT BANK PLAN ST-20131-9A-E-304 FEEDER 9A DUCT BANK PLAN ST-20131-9A-E-305 FEEDER 9A DUCT BANK PLAN ST-20131-9A-E-306 FEEDER 9A DUCT BANK PLAN DUCT BANK DETAILS STT-20131-9A-E-103 STANDARD MANHOLE DETAILS STT-20131-9A-E-102 TRANSFORMER DETAILS ONE LINE DIAGRAM (PHASE 2) ST-20131-9A-E-201 CHARLOTTE AMALIE PROJECT LOCATION MAP: FEEDER 9A 5 C h r i s t y D r i v e , S u i t e 3 0 7 C h a d d s F o r d , P A 1 9 3 1 7 6 1 0 . 5 5 8 . 3 4 6 4 o f f i c e w w w . f x b i n c . c o m Engineering Excellence Since 1968 Y A P D O N R A R I T O H E W U T I N G R I V W I D S A T R E A L S N ENLARGED PROJECT LOCATION MAP: FEEDER 9A - PHASE 1 & 2 LATITUDE: 18.332550 LONGITUDE: -64.962116 PHASE 1 START POINT LATITUDE: 18.341908 LONGITUDE: -64.934772 PHASE 1 END POINT LATITUDE: 18.335498 LONGITUDE: -64.952795 PHASE 2 START POINT LATITUDE: 18.336959 LONGITUDE: -64.948208 PHASE 2 END POINT LATITUDE: 18.341216 LONGITUDE: -64.939790 PHASE 2 START POINT LATITUDE: 18.3387673 LONGITUDE: -64.939162 PHASE 2 END POINT ENLARGED PROJECT LOCATION MAP: FEEDER 9A - PHASE 3 (NOT IN CONTRACT) LATITUDE: 18.3329125 LONGITUDE: -64.9622551 PHASE 3 START POINT LATITUDE: 18.342272 LONGITUDE: -64.927613 PHASE 3 END POINT PRO-ECT LOCATION: FEEDER 9A ENLARGED SCOPE OF WORK: FEEDER 9A - PHASE 1 NO CIVIL WORK REQUIRED DUCT BANK IS E;ISTING TO REMAIN ENLARGED SCOPE OF WORK: FEEDER 9A - PHASE 2 NEW DUCT BANK REQUIRED (CONTAINER PORT) ENLARGED SCOPE OF WORK: FEEDER 9A - PHASE 3 NEW DUCT BANK REQUIRED ENGINEER: ISSUE FOR FEMA REVIEW (75%) ISSUE B: 12.02.2022 STT-20131-9A-E-103 SWITCHGEAR  SECTIONALIZING CABINET PAD DETAILS & HANDHOLE DETAILS ISSUE FOR 100% REVIEW ISSUE C: 04.21.2022 ST-20131-9A-E-500 ENLARGED PLANS FEEDER 9A ST-20131-9A-E-501 ENLARGED PLANS FEEDER 9A ST-20131-9A-E-502 ENLARGED PLANS FEEDER 9A ST-20131-9A-E-503 ENLARGED PLANS FEEDER 9A ISSUE FOR CZM APPLICATION ISSUE D: 06.07.2022 ST-20131-9A-E-504 ENLARGED PLANS FEEDER 9A ST-20131-9A-E-504 DUCT BANK PROFILES ENLARGED SCOPE OF WORK: FEEDER 9A - PHASE 2 NEW DUCT BANK REQUIRED (GASVAERKS GADE) METHOD OF PROCEDURE ("M.O.P.") OWNER FURNISHED EQUIPMENT: ELECTRICAL TESTING REQUIREMENTS STT-20131-9A-G-100 GENERAL CONSTRUCTION NOTES & ABBREVIATIONS 2022 FXB, Inc C T I A : T E R 9 G I R I S ' L A S I N N ' 3 N A : + 2 T U E R A 2 R < Engineers Seal Date: Chk'd By: Drawn By: Scale: Drawing Title: Drawing Number: Issue / Revisions: # Date Description Project Number: NS/BM/CM/CC/PJB PJB 06.07.2023 As Noted Project Name: Client: VIT 20131 5 C h r i s t y D r i v e , S u i t e 3 0 7 C h a d d s F o r d , P A 1 9 3 1 7 6 1 0 . 5 5 8 . 3 4 6 4 o f f i c e w w w . f x b i n c . c o m Engineering Excellence Since 1968 Charlotte Amalie Underground Electrical Construction Project (Feeder 9A Phase 1 & 2), St Thomas, USVI A 06/24/22 Issue for EHP Review B 12/02/22 Issue for FEMA Review (75%) Engineer: C 04/21/23 Issue for 100% Review D 06/07/23 Issue for CZM Application LOAN & SEED DETAIL EXCAVATION AND ROAD RESTORATION NOTES BOLLARD DETAIL CONCRETE SIDEWALK REPLACEMENT DETAIL CONCRETE SIDEWALK REPLACEMENT DETAIL LONGITUDINAL VIEW CONCRETE CURB REPLACEMENT BITUMINOUS PAVEMENT RESTORATION DETAIL CONCRETE / ASPHALT ROADWAY REPLACEMENT DETAIL SECTION VIEW CONCRETE ROADWAY REPLACEMENT DETAIL LONGITUDINAL VIEW EXPANSION JOINT CONTROL JOINT GENERAL CONSTRUCTION DETAILS STT-20131-9A-G-101 2022 FXB, Inc C T I A W T E R V G I R I S D L A S I N N D P N A W H O T U E R A O R Y Engineers Seal Date: Chk'd By: Drawn By: Scale: Drawing Title: Drawing Number: Issue / Revisions: # Date Description Project Number: NS/BM/CM/CC/PJB PJB 06.07.2023 As Noted Project Name: Client: VIT 20131 5 C h r i s t y D r i v e , S u i t e 3 0 7 C h a d d s F o r d , P A 1 9 3 1 7 6 1 0 . 5 5 8 . 3 4 6 4 o f f i c e w w w . f x b i n c . c o m Engineering Excellence Since 1968 Charlotte Amalie Underground Electrical Construction Project (Feeder 9A Phase 1 & 2), St Thomas, USVI A 06/24/22 Issue for EHP Review B 12/02/22 Issue for FEMA Review (75%) Engineer: C 04/21/23 Issue for 100% Review D 06/07/23 Issue for CZM Application SUMP DETAIL WATER STOP DETAIL CABLE RACK - COMMUNICATIONS ENLARGED PLAN NON-METALLIC SCALE: NONE 1 2 3 4 4 5 TYPICAL MANHOLE ACCESSORY BILL OF MATERIAL (PER MANHOLE) 1 2 3 4 5 ITEM NUMBER MANUFACTURER CATALOG NUMBER DESCRIPTION QTY. TYPICAL HANDHOLE ACCESSORY BILL OF MATERIAL (PER HANDHOLE) NON-METALLIC CABLE RACK ENLARGED PLAN 1 2 3 4 5 6 STT-20131-9A-E-100 ELECTRICAL DETAILS AND SCHEDULES 2022 FXB, Inc C T I A W T E R 9 G I R I S D L A S I N N D P N A W H O T U E R A O R Y Engineers Seal Date: Chk'd By: Drawn By: Scale: Drawing Title: Drawing Number: Issue / Revisions: # Date Description Project Number: NS/BM/CM/CC/PJB PJB 06.07.2023 As Noted Project Name: Client: VIT 20131 5 C h r i s t y D r i v e , S u i t e 3 0 7 C h a d d s F o r d , P A 1 9 3 1 7 6 1 0 . 5 5 8 . 3 4 6 4 o f f i c e w w w . f x b i n c . c o m Engineering Excellence Since 1968 Charlotte Amalie Underground Electrical Construction Project (Feeder 9A Phase 1 & 2), St Thomas, USVI A 06/24/22 Issue for EHP Review B 12/02/22 Issue for FEMA Review (75%) Engineer: C 04/21/23 Issue for 100% Review D 06/07/23 Issue for CZM Application MANHOLE - TOP VIEW MANHOLE GENERAL NOTES SECTION "A-A" INTERFACE DETAIL DUCT BANK TO MANHOLE CROSS SECTION "B-B" MANHOLE DETAIL MANHOLE DETAIL · · · · · · · · · MANHOLE - TOP VIEW (COVER REMOVED) (ALONG GASVAERKS GADE) MANHOLE - TOP VIEW (W/CABLES) SECTION INTERFACE DETAIL DUCT BANK TO MANHOLE SCALE: 1/2" = 1'-0" ELECTRIC MANHOLE ISOMETRIC VIEW-ELECTRIC MANHOLE (ALONG SUBBASE ROAD) NTS OLDCASTLE PRECAST MODEL #MH-660-EL OR EQUAL PLAN VIEW - STRAIGHT PULL TOP REMOVED SCALE: 1/2" = 1'-0" ELECTRIC MANHOLE (ALONMG SUBBASE ROAD) TOP VIEW - STRAIGHT PULL NTS ELECTRIC MANHOLE STANDARD MANHOLE DETAILS 2022 FXB, Inc C T I A W T E R V G I R I S D L A S I N N D P N A W H O T U E R A O R < Engineers Seal Date: Chk'd By: Drawn By: Scale: Drawing Title: Drawing Number: Issue / Revisions: # Date Description Project Number: NS/BM/CM/CC/PJB PJB 06.07.2023 As Noted Project Name: Client: VIT 20131 5 C h r i s t y D r i v e , S u i t e 3 0 7 C h a d d s F o r d , P A 1 9 3 1 7 6 1 0 . 5 5 8 . 3 4 6 4 o f f i c e w w w . f x b i n c . c o m Engineering Excellence Since 1968 Charlotte Amalie Underground Electrical Construction Project (Feeder 9A Phase 1 & 2), St Thomas, USVI A 06/24/22 Issue for EHP Review B 12/02/22 Issue for FEMA Review (75%) Engineer: C 04/21/23 Issue for 100% Review D 06/07/23 Issue for CZM Application STT-20131-9A-E-101 CONCRETE PAD NOTES TRANSFORMER DETAILS 2022 FXB, Inc C T , A : T E R 9 * , R , S D / A S , N N D P N A : + O T 8 E R A O R < Engineers Seal Date: Chk'd By: Drawn By: Scale: Drawing Title: Drawing Number: Issue / Revisions: # Date Description Project Number: NS/BM/CM/CC/PJB PJB 06.07.2023 As Noted Project Name: Client: VIT 20131 5 C h r i s t y D r i v e , S u i t e 3 0 7 C h a d d s F o r d , P A 1 9 3 1 7 6 1 0 . 5 5 8 . 3 4 6 4 o f f i c e w w w . f x b i n c . c o m Engineering Excellence Since 1968 Charlotte Amalie Underground Electrical Construction Project (Feeder 9A Phase 1 & 2), St Thomas, USVI A 06/24/22 Issue for EHP Review B 12/02/22 Issue for FEMA Review (75%) Engineer: C 04/21/23 Issue for 100% Review D 06/07/23 Issue for CZM Application STT-20131-9A-E-102 SECTION C-C TOP VIEW NTS SCALE: 1/2" = 1'-0" COMMUNICATIONS HANDHOLE COMMUNICATIONS HANDHOLE PLAN VIEW SCALE: 1/2" = 1'-0" TYPICAL COMMUNICATIONS HANDHOLE INSTALLATION DETAIL POLYMER HANDHOLE COMMUNICATIONS HANDHOLE GENERAL NOTES · · · · · · · · CONCRETE PAD NOTES SECTION D-D TOP VIEW NTS SCALE: 1/2" = 1'-0" ELECTRIC SECONDARY HANDHOLE ELECTRIC HANDHOLE PLAN VIEW SCALE: 1/2" = 1'-0" TYPICAL ELECTRIC SECONDARY HANDHOLE ELECTRIC TOP VIEW NTS ELECTRIC PRIMARY HANDHOLE PLAN VIEW SCALE: 1/2" = 1'-0" TYPICAL ELECTRIC PRIMARY HANDHOLE ELECTRIC SWITCHGEAR / SECTIONALIZING CABINET PAD DETAILS & HANDHOLE DETAILS 2022 FXB, Inc C T I A W T E R V G I R I S D L A S I N N D P N A W H O T U E R A O R Y Engineers Seal Date: Chk'd By: Drawn By: Scale: Drawing Title: Drawing Number: Issue / Revisions: # Date Description Project Number: NS/BM/CM/CC/PJB PJB 06.07.2023 As Noted Project Name: Client: VIT 20131 5 C h r i s t y D r i v e , S u i t e 3 0 7 C h a d d s F o r d , P A 1 9 3 1 7 6 1 0 . 5 5 8 . 3 4 6 4 o f f i c e w w w . f x b i n c . c o m Engineering Excellence Since 1968 Charlotte Amalie Underground Electrical Construction Project (Feeder 9A Phase 1 & 2), St Thomas, USVI A 06/24/22 Issue for EHP Review B 12/02/22 Issue for FEMA Review (75%) Engineer: C 04/21/23 Issue for 100% Review D 06/07/23 Issue for CZM Application STT-20131-9A-E-103 SECTION F-F SECTION K-K SECTION H-H SECTION C-C SECTION C-C (ALT) ADDITIONAL NOTES FOR CONCRETE DUCT BANKS DUCT BANK NOTES SECTION D-D SECTION A-A SECTION B-B SECTION A-A (ALT) STEPPED CONCRETE ENVELOPE DETAIL DUCT BANK DETAIL W/ 24" OR LESS FROM GRADE TO TOP OF CONCRETE SECTION E-E SECTION G-G SECTION J-J SECTION L-L DUCT BANK DETAILS 2022 FXB, Inc C T I A W T E R V G I R I S D L A S I N N D P N A W H O T U E R A O R < Engineers Seal Date: Chk'd By: Drawn By: Scale: Drawing Title: Drawing Number: Issue / Revisions: # Date Description Project Number: NS/BM/CM/CC/PJB PJB 06.07.2023 As Noted Project Name: Client: VIT 20131 5 C h r i s t y D r i v e , S u i t e 3 0 7 C h a d d s F o r d , P A 1 9 3 1 7 6 1 0 . 5 5 8 . 3 4 6 4 o f f i c e w w w . f x b i n c . c o m Engineering Excellence Since 1968 Charlotte Amalie Underground Electrical Construction Project (Feeder 9A Phase 1 & 2), St Thomas, USVI A 06/24/22 Issue for EHP Review B 12/02/22 Issue for FEMA Review (75%) Engineer: C 04/21/23 Issue for 100% Review D 06/07/23 Issue for CZM Application STT-20131-9A-E-104 GROUNDING NOTES GROUNDING SYSTEM BILL OF MATERIAL FOR GROUNDING DETAILS 2022 FXB, Inc C T I A : T E R 9 G I R I S D L A S I N N D 3 N A : + O T U E R A O R Y Engineers Seal Date: Chk'd By: Drawn By: Scale: Drawing Title: Drawing Number: Issue / Revisions: # Date Description Project Number: NS/BM/CM/CC/PJB PJB 06.07.2023 As Noted Project Name: Client: VIT 20131 5 C h r i s t y D r i v e , S u i t e 3 0 7 C h a d d s F o r d , P A 1 9 3 1 7 6 1 0 . 5 5 8 . 3 4 6 4 o f f i c e w w w . f x b i n c . c o m Engineering Excellence Since 1968 Charlotte Amalie Underground Electrical Construction Project (Feeder 9A Phase 1 & 2), St Thomas, USVI A 06/24/22 Issue for EHP Review B 12/02/22 Issue for FEMA Review (75%) Engineer: C 04/21/23 Issue for 100% Review D 06/07/23 Issue for CZM Application STT-20131-9A-E-105 NOT TO SCALE 1 E-200 ONE LINE DIAGRAM PHASE 1 2022 FXB, Inc C T I A W T E R V G I R I S D L A S I N N D P N A W H O T U E R A O R Y Engineers Seal Date: Chk'd By: Drawn By: Scale: Drawing Title: Drawing Number: Issue / Revisions: # Date Description Project Number: NS/BM/CM/CC/PJB PJB 06.07.2023 As Noted Project Name: Client: VIT 20131 5 C h r i s t y D r i v e , S u i t e 3 0 7 C h a d d s F o r d , P A 1 9 3 1 7 6 1 0 . 5 5 8 . 3 4 6 4 o f f i c e w w w . f x b i n c . c o m Engineering Excellence Since 1968 Charlotte Amalie Underground Electrical Construction Project (Feeder 9A Phase 1 & 2), St Thomas, USVI A 06/24/22 Issue for EHP Review B 12/02/22 Issue for FEMA Review (75%) Engineer: C 04/21/23 Issue for 100% Review D 06/07/23 Issue for CZM Application STT-20131-9A-E-200 ONE LINE DIAGRAM (PHASE 1) NOT TO SCALE 1 E-201 ONE LINE DIAGRAM PHASE 2 (CONTAINER PORT) NOT TO SCALE 2 E-201 ONE LINE DIAGRAM PHASE 2 (GASVAERKS GADE) 2022 FXB, Inc C T I A W T E R V G I R I S D L A S I N N D P N A W H O T U E R A O R Y Engineers Seal Date: Chk'd By: Drawn By: Scale: Drawing Title: Drawing Number: Issue / Revisions: # Date Description Project Number: NS/BM/CM/CC/PJB PJB 06.07.2023 As Noted Project Name: Client: VIT 20131 5 C h r i s t y D r i v e , S u i t e 3 0 7 C h a d d s F o r d , P A 1 9 3 1 7 6 1 0 . 5 5 8 . 3 4 6 4 o f f i c e w w w . f x b i n c . c o m Engineering Excellence Since 1968 Charlotte Amalie Underground Electrical Construction Project (Feeder 9A Phase 1 & 2), St Thomas, USVI A 06/24/22 Issue for EHP Review B 12/02/22 Issue for FEMA Review (75%) Engineer: C 04/21/23 Issue for 100% Review D 06/07/23 Issue for CZM Application STT-20131-9A-E-201 ONE LINE DIAGRAM (PHASE 2) 2022 FXB, Inc C T I A W T E R V G I R I S D L A S I N N D P N A W H O T U E R A O R Y Engineers Seal Date: Chk'd By: Drawn By: Scale: Drawing Title: Drawing Number: Issue / Revisions: # Date Description Project Number: NS/BM/CM/CC/PJB PJB 06.07.2023 As Noted Project Name: Client: VIT 20131 5 C h r i s t y D r i v e , S u i t e 3 0 7 C h a d d s F o r d , P A 1 9 3 1 7 6 1 0 . 5 5 8 . 3 4 6 4 o f f i c e w w w . f x b i n c . c o m Engineering Excellence Since 1968 Charlotte Amalie Underground Electrical Construction Project (Feeder 9A Phase 1 & 2), St Thomas, USVI A 06/24/22 Issue for EHP Review B 12/02/22 Issue for FEMA Review (75%) Engineer: C 04/21/23 Issue for 100% Review D 06/07/23 Issue for CZM Application FEEDER 9A DUCT BANK PLAN STT-20131-9A-E-300 MATCH LINE - DRAWING ST-20131-9A-E-301 SCALE: 1" = 50' - 0" DUCT BANK PLAN LEGEND 2022 FXB, Inc C T I A W T E R V G I R I S D L A S I N N D P N A W H O T U E R A O R Y Engineers Seal Date: Chk'd By: Drawn By: Scale: Drawing Title: Drawing Number: Issue / Revisions: # Date Description Project Number: NS/BM/CM/CC/PJB PJB 06.07.2023 As Noted Project Name: Client: VIT 20131 5 C h r i s t y D r i v e , S u i t e 3 0 7 C h a d d s F o r d , P A 1 9 3 1 7 6 1 0 . 5 5 8 . 3 4 6 4 o f f i c e w w w . f x b i n c . c o m Engineering Excellence Since 1968 Charlotte Amalie Underground Electrical Construction Project (Feeder 9A Phase 1 & 2), St Thomas, USVI A 06/24/22 Issue for EHP Review B 12/02/22 Issue for FEMA Review (75%) Engineer: C 04/21/23 Issue for 100% Review D 06/07/23 Issue for CZM Application FEEDER 9A DUCT BANK PLAN STT-20131-9A-E-301 MATCH LINE - DRAWING ST-20131-9A-E-300 MATCH LINE - DRAWING ST-20131-9A-E-302 SCALE: 1" = 50' - 0" DUCT BANK PLAN LEGEND 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 20+00 2022 FXB, Inc C T I A W T E R V G I R I S D L A S I N N D P N A W H O T U E R A O R Y Engineers Seal Date: Chk'd By: Drawn By: Scale: Drawing Title: Drawing Number: Issue / Revisions: # Date Description Project Number: NS/BM/CM/CC/PJB PJB 06.07.2023 As Noted Project Name: Client: VIT 20131 5 C h r i s t y D r i v e , S u i t e 3 0 7 C h a d d s F o r d , P A 1 9 3 1 7 6 1 0 . 5 5 8 . 3 4 6 4 o f f i c e w w w . f x b i n c . c o m Engineering Excellence Since 1968 Charlotte Amalie Underground Electrical Construction Project (Feeder 9A Phase 1 & 2), St Thomas, USVI A 06/24/22 Issue for EHP Review B 12/02/22 Issue for FEMA Review (75%) Engineer: C 04/21/23 Issue for 100% Review D 06/07/23 Issue for CZM Application FEEDER 9A DUCT BANK PLAN STT-20131-9A-E-302 MATCH LINE - DRAWING ST-20131-9A-E-301 MATCH LINE - DRAWING ST-20131-9A-E-303 SCALE: 1" = 50' - 0" DUCT BANK PLAN LEGEND 2022 FXB, Inc C T I A W T E R V G I R I S D L A S I N N D P N A W H O T U E R A O R Y Engineers Seal Date: Chk'd By: Drawn By: Scale: Drawing Title: Drawing Number: Issue / Revisions: # Date Description Project Number: NS/BM/CM/CC/PJB PJB 06.07.2023 As Noted Project Name: Client: VIT 20131 5 C h r i s t y D r i v e , S u i t e 3 0 7 C h a d d s F o r d , P A 1 9 3 1 7 6 1 0 . 5 5 8 . 3 4 6 4 o f f i c e w w w . f x b i n c . c o m Engineering Excellence Since 1968 Charlotte Amalie Underground Electrical Construction Project (Feeder 9A Phase 1 & 2), St Thomas, USVI A 06/24/22 Issue for EHP Review B 12/02/22 Issue for FEMA Review (75%) Engineer: C 04/21/23 Issue for 100% Review D 06/07/23 Issue for CZM Application FEEDER 9A DUCT BANK PLAN STT-20131-9A-E-303 MATCH LINE - DRAWING ST-20131-9A-E-304 MATCH LINE - DRAWING ST-20131-9A-E-302 SCALE: 1" = 50' - 0" DUCT BANK PLAN LEGEND 2022 FXB, Inc C T I A W T E R V G I R I S D L A S I N N D P N A W H O T U E R A O R Y Engineers Seal Date: Chk'd By: Drawn By: Scale: Drawing Title: Drawing Number: Issue / Revisions: # Date Description Project Number: NS/BM/CM/CC/PJB PJB 06.07.2023 As Noted Project Name: Client: VIT 20131 5 C h r i s t y D r i v e , S u i t e 3 0 7 C h a d d s F o r d , P A 1 9 3 1 7 6 1 0 . 5 5 8 . 3 4 6 4 o f f i c e w w w . f x b i n c . c o m Engineering Excellence Since 1968 Charlotte Amalie Underground Electrical Construction Project (Feeder 9A Phase 1 & 2), St Thomas, USVI A 06/24/22 Issue for EHP Review B 12/02/22 Issue for FEMA Review (75%) Engineer: C 04/21/23 Issue for 100% Review D 06/07/23 Issue for CZM Application FEEDER 9A DUCT BANK PLAN STT-20131-9A-E-304 MATCH LINE - DRAWING ST-20131-9A-E-303 MATCH LINE - DRAWING ST-20131-9A-E-305 SCALE: 1" = 50' - 0" DUCT BANK PLAN LEGEND 20+10 21+00 22+00 23+00 24+00 25+00 26+00 27+00 28+00 29+00 30+00 30+91 31+00 32+00 33+00 34+00 34+45 2022 FXB, Inc C T I A W T E R V G I R I S D L A S I N N D P N A W H O T U E R A O R Y Engineers Seal Date: Chk'd By: Drawn By: Scale: Drawing Title: Drawing Number: Issue / Revisions: # Date Description Project Number: NS/BM/CM/CC/PJB PJB 06.07.2023 As Noted Project Name: Client: VIT 20131 5 C h r i s t y D r i v e , S u i t e 3 0 7 C h a d d s F o r d , P A 1 9 3 1 7 6 1 0 . 5 5 8 . 3 4 6 4 o f f i c e w w w . f x b i n c . c o m Engineering Excellence Since 1968 Charlotte Amalie Underground Electrical Construction Project (Feeder 9A Phase 1 & 2), St Thomas, USVI A 06/24/22 Issue for EHP Review B 12/02/22 Issue for FEMA Review (75%) Engineer: C 04/21/23 Issue for 100% Review D 06/07/23 Issue for CZM Application FEEDER 9A DUCT BANK PLAN STT-20131-9A-E-305 MATCH LINE - DRAWING ST-20131-9A-E-304 MATCH LINE - DRAWING ST-20131-9A-E-306 SCALE: 1" = 50' - 0" DUCT BANK PLAN LEGEND 2022 FXB, Inc C T I A W T E R V G I R I S D L A S I N N D P N A W H O T U E R A O R Y Engineers Seal Date: Chk'd By: Drawn By: Scale: Drawing Title: Drawing Number: Issue / Revisions: # Date Description Project Number: NS/BM/CM/CC/PJB PJB 06.07.2023 As Noted Project Name: Client: VIT 20131 5 C h r i s t y D r i v e , S u i t e 3 0 7 C h a d d s F o r d , P A 1 9 3 1 7 6 1 0 . 5 5 8 . 3 4 6 4 o f f i c e w w w . f x b i n c . c o m Engineering Excellence Since 1968 Charlotte Amalie Underground Electrical Construction Project (Feeder 9A Phase 1 & 2), St Thomas, USVI A 06/24/22 Issue for EHP Review B 12/02/22 Issue for FEMA Review (75%) Engineer: C 04/21/23 Issue for 100% Review D 06/07/23 Issue for CZM Application FEEDER 9A DUCT BANK PLAN STT-20131-9A-E-306 MATCH LINE - DRAWING ST-20131-9A-E-305 SCALE: 1" = 50' - 0" DUCT BANK PLAN LEGEND ELECTRICAL EQUIPMENT AND DUCT BANK SCHEDULES STT-20131-9A-E-400 2022 FXB, Inc C T I A W T E R V G I R I S D L A S I N N D P N A W H O T U E R A O R Y Engineers Seal Date: Chk'd By: Drawn By: Scale: Drawing Title: Drawing Number: Issue / Revisions: # Date Description Project Number: NS/BM/CM/CC/PJB PJB 06.07.2023 As Noted Project Name: Client: VIT 20131 5 C h r i s t y D r i v e , S u i t e 3 0 7 C h a d d s F o r d , P A 1 9 3 1 7 6 1 0 . 5 5 8 . 3 4 6 4 o f f i c e w w w . f x b i n c . c o m Engineering Excellence Since 1968 Charlotte Amalie Underground Electrical Construction Project (Feeder 9A Phase 1 & 2), St Thomas, USVI A 06/24/22 Issue for EHP Review B 12/02/22 Issue for FEMA Review (75%) Engineer: C 04/21/23 Issue for 100% Review D 06/07/23 Issue for CZM Application 2022 FXB, Inc C T I A W T E R V G I R I S D L A S I N N D P N A W H O T U E R A O R Y Engineers Seal Date: Chk'd By: Drawn By: Scale: Drawing Title: Drawing Number: Issue / Revisions: # Date Description Project Number: NS/BM/CM/CC/PJB PJB 06.07.2023 As Noted Project Name: Client: VIT 20131 5 C h r i s t y D r i v e , S u i t e 3 0 7 C h a d d s F o r d , P A 1 9 3 1 7 6 1 0 . 5 5 8 . 3 4 6 4 o f f i c e w w w . f x b i n c . c o m Engineering Excellence Since 1968 Charlotte Amalie Underground Electrical Construction Project (Feeder 9A Phase 1 & 2), St Thomas, USVI A 06/24/22 Issue for EHP Review B 12/02/22 Issue for FEMA Review (75%) Engineer: C 04/21/23 Issue for 100% Review D 06/07/23 Issue for CZM Application DUCT BANK ROFILES STT-20131-9A-E-600 SCALE: 1" = 50' - 0" DUCT BANK PROFILE 2 (GASVAERKS GADE) DUCT BANK PROFILE 1.2 (CONTAINER PORT) DUCT BANK PROFILE 1.1 (CONTAINER PORT) SCALE: 1" = 50' - 0" SCALE: 1" = 50' - 0"